Cargando…

Challenges to the Common Clinical Paradigm for Diagnosis of Glaucomatous Damage With OCT and Visual Fields

The most common clinical paradigm (CCP) for diagnosing glaucoma includes a visual field (VF) with a 6° test grid (e.g., the 24-2 or 30-2 test pattern) and an optical coherence tomography (OCT) scan of the optic disc. Furthermore, these tests are assessed based upon quantitative metrics (e.g., the pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Hood, Donald C., De Moraes, Carlos Gustavo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6110166/
https://www.ncbi.nlm.nih.gov/pubmed/29392325
http://dx.doi.org/10.1167/iovs.17-23713
_version_ 1783350426921336832
author Hood, Donald C.
De Moraes, Carlos Gustavo
author_facet Hood, Donald C.
De Moraes, Carlos Gustavo
author_sort Hood, Donald C.
collection PubMed
description The most common clinical paradigm (CCP) for diagnosing glaucoma includes a visual field (VF) with a 6° test grid (e.g., the 24-2 or 30-2 test pattern) and an optical coherence tomography (OCT) scan of the optic disc. Furthermore, these tests are assessed based upon quantitative metrics (e.g., the pattern standard deviation [PSD] of the VF and the global retinal nerve fiber thickness of the OCT disc scan). This CCP is facing three challenges. First, the macular region (i.e., ±8° from fixation) is affected early in the glaucomatous process, and the CCP can miss and/or underestimate the damage. Second, use of the typical VF and OCT metrics underestimates the degree of agreement between structural (OCT) and functional (VF) damage. Third, resolution of the OCT scan has improved, and local glaucomatous damage can be visualized like never before. However, the clinician often does not look at the OCT scan image. Together these challenges argue for a modification of the VF test pattern and OCT protocol, replacement of metrics with a comparison of abnormal regions on VF and OCT, and careful inspection of actual OCT scan images. In principle, the CCP could be modified easily. In practice, change is facing a number of impediments.
format Online
Article
Text
id pubmed-6110166
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-61101662018-08-29 Challenges to the Common Clinical Paradigm for Diagnosis of Glaucomatous Damage With OCT and Visual Fields Hood, Donald C. De Moraes, Carlos Gustavo Invest Ophthalmol Vis Sci Perspective The most common clinical paradigm (CCP) for diagnosing glaucoma includes a visual field (VF) with a 6° test grid (e.g., the 24-2 or 30-2 test pattern) and an optical coherence tomography (OCT) scan of the optic disc. Furthermore, these tests are assessed based upon quantitative metrics (e.g., the pattern standard deviation [PSD] of the VF and the global retinal nerve fiber thickness of the OCT disc scan). This CCP is facing three challenges. First, the macular region (i.e., ±8° from fixation) is affected early in the glaucomatous process, and the CCP can miss and/or underestimate the damage. Second, use of the typical VF and OCT metrics underestimates the degree of agreement between structural (OCT) and functional (VF) damage. Third, resolution of the OCT scan has improved, and local glaucomatous damage can be visualized like never before. However, the clinician often does not look at the OCT scan image. Together these challenges argue for a modification of the VF test pattern and OCT protocol, replacement of metrics with a comparison of abnormal regions on VF and OCT, and careful inspection of actual OCT scan images. In principle, the CCP could be modified easily. In practice, change is facing a number of impediments. The Association for Research in Vision and Ophthalmology 2018-02 /pmc/articles/PMC6110166/ /pubmed/29392325 http://dx.doi.org/10.1167/iovs.17-23713 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Perspective
Hood, Donald C.
De Moraes, Carlos Gustavo
Challenges to the Common Clinical Paradigm for Diagnosis of Glaucomatous Damage With OCT and Visual Fields
title Challenges to the Common Clinical Paradigm for Diagnosis of Glaucomatous Damage With OCT and Visual Fields
title_full Challenges to the Common Clinical Paradigm for Diagnosis of Glaucomatous Damage With OCT and Visual Fields
title_fullStr Challenges to the Common Clinical Paradigm for Diagnosis of Glaucomatous Damage With OCT and Visual Fields
title_full_unstemmed Challenges to the Common Clinical Paradigm for Diagnosis of Glaucomatous Damage With OCT and Visual Fields
title_short Challenges to the Common Clinical Paradigm for Diagnosis of Glaucomatous Damage With OCT and Visual Fields
title_sort challenges to the common clinical paradigm for diagnosis of glaucomatous damage with oct and visual fields
topic Perspective
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6110166/
https://www.ncbi.nlm.nih.gov/pubmed/29392325
http://dx.doi.org/10.1167/iovs.17-23713
work_keys_str_mv AT hooddonaldc challengestothecommonclinicalparadigmfordiagnosisofglaucomatousdamagewithoctandvisualfields
AT demoraescarlosgustavo challengestothecommonclinicalparadigmfordiagnosisofglaucomatousdamagewithoctandvisualfields