Cargando…

Effect of Interventricular Electrical Delay on Atrioventricular Optimization for Cardiac Resynchronization Therapy

BACKGROUND: Routine atrioventricular optimization (AVO) has not been shown to improve outcomes with cardiac resynchronization therapy (CRT). However, more recently subgroup analyses of multicenter CRT trials have identified electrocardiographic or lead positions associated with benefit from AVO. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Gold, Michael R., Yu, Yinghong, Singh, Jagmeet P., Birgersdotter-Green, Ulrika, Stein, Kenneth M., Wold, Nicholas, Meyer, Timothy E., Ellenbogen, Kenneth A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6110372/
https://www.ncbi.nlm.nih.gov/pubmed/30354310
http://dx.doi.org/10.1161/CIRCEP.117.006055
_version_ 1783350463526076416
author Gold, Michael R.
Yu, Yinghong
Singh, Jagmeet P.
Birgersdotter-Green, Ulrika
Stein, Kenneth M.
Wold, Nicholas
Meyer, Timothy E.
Ellenbogen, Kenneth A.
author_facet Gold, Michael R.
Yu, Yinghong
Singh, Jagmeet P.
Birgersdotter-Green, Ulrika
Stein, Kenneth M.
Wold, Nicholas
Meyer, Timothy E.
Ellenbogen, Kenneth A.
author_sort Gold, Michael R.
collection PubMed
description BACKGROUND: Routine atrioventricular optimization (AVO) has not been shown to improve outcomes with cardiac resynchronization therapy (CRT). However, more recently subgroup analyses of multicenter CRT trials have identified electrocardiographic or lead positions associated with benefit from AVO. Therefore, the purpose of this analysis was to evaluate whether interventricular electrical delay modifies the impact of AVO on reverse remodeling with CRT. METHODS: This substudy of the SMART-AV trial (SMARTDELAY Determined AV Optimization) included 275 subjects who were randomized to either an electrogram-based AVO (SmartDelay) or nominal atrioventricular delay (120 ms). Interventricular delay was defined as the time between the peaks of the right ventricular (RV) and left ventricular (LV) electrograms (RV-LV duration). CRT response was defined prospectively as a >15% reduction in LV end-systolic volume from implant to 6 months. RESULTS: The cohort was 68% men, with a mean age of 65±11 years and LV ejection fraction of 28±8%. Longer RV-LV durations were significantly associated with CRT response (P<0.01) for the entire cohort. Moreover, the benefit of AVO increased as RV-LV duration prolonged. At the longest quartile, there was a 4.26× greater odds of a remodeling response compared with nominal atrioventricular delays (P=0.010). CONCLUSIONS: Baseline interventricular delay predicted CRT response. At long RV-LV durations, AVO can increase the likelihood of reverse remodeling with CRT. AVO and LV lead location optimized to maximize interventricular delay may work synergistically to increase CRT response. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00874445.
format Online
Article
Text
id pubmed-6110372
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-61103722018-09-07 Effect of Interventricular Electrical Delay on Atrioventricular Optimization for Cardiac Resynchronization Therapy Gold, Michael R. Yu, Yinghong Singh, Jagmeet P. Birgersdotter-Green, Ulrika Stein, Kenneth M. Wold, Nicholas Meyer, Timothy E. Ellenbogen, Kenneth A. Circ Arrhythm Electrophysiol Original Articles BACKGROUND: Routine atrioventricular optimization (AVO) has not been shown to improve outcomes with cardiac resynchronization therapy (CRT). However, more recently subgroup analyses of multicenter CRT trials have identified electrocardiographic or lead positions associated with benefit from AVO. Therefore, the purpose of this analysis was to evaluate whether interventricular electrical delay modifies the impact of AVO on reverse remodeling with CRT. METHODS: This substudy of the SMART-AV trial (SMARTDELAY Determined AV Optimization) included 275 subjects who were randomized to either an electrogram-based AVO (SmartDelay) or nominal atrioventricular delay (120 ms). Interventricular delay was defined as the time between the peaks of the right ventricular (RV) and left ventricular (LV) electrograms (RV-LV duration). CRT response was defined prospectively as a >15% reduction in LV end-systolic volume from implant to 6 months. RESULTS: The cohort was 68% men, with a mean age of 65±11 years and LV ejection fraction of 28±8%. Longer RV-LV durations were significantly associated with CRT response (P<0.01) for the entire cohort. Moreover, the benefit of AVO increased as RV-LV duration prolonged. At the longest quartile, there was a 4.26× greater odds of a remodeling response compared with nominal atrioventricular delays (P=0.010). CONCLUSIONS: Baseline interventricular delay predicted CRT response. At long RV-LV durations, AVO can increase the likelihood of reverse remodeling with CRT. AVO and LV lead location optimized to maximize interventricular delay may work synergistically to increase CRT response. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00874445. Lippincott Williams & Wilkins 2018-08 2018-08-20 /pmc/articles/PMC6110372/ /pubmed/30354310 http://dx.doi.org/10.1161/CIRCEP.117.006055 Text en © 2018 The Authors. Circulation: Arrhythmia and Electrophysiology is published on behalf of the American Heart Association, Inc., by Wolters Kluwer Health, Inc. This is an open access article under the terms of the Creative Commons Attribution Non-Commercial-NoDerivs (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use, distribution, and reproduction in any medium, provided that the original work is properly cited, the use is noncommercial, and no modifications or adaptations are made.
spellingShingle Original Articles
Gold, Michael R.
Yu, Yinghong
Singh, Jagmeet P.
Birgersdotter-Green, Ulrika
Stein, Kenneth M.
Wold, Nicholas
Meyer, Timothy E.
Ellenbogen, Kenneth A.
Effect of Interventricular Electrical Delay on Atrioventricular Optimization for Cardiac Resynchronization Therapy
title Effect of Interventricular Electrical Delay on Atrioventricular Optimization for Cardiac Resynchronization Therapy
title_full Effect of Interventricular Electrical Delay on Atrioventricular Optimization for Cardiac Resynchronization Therapy
title_fullStr Effect of Interventricular Electrical Delay on Atrioventricular Optimization for Cardiac Resynchronization Therapy
title_full_unstemmed Effect of Interventricular Electrical Delay on Atrioventricular Optimization for Cardiac Resynchronization Therapy
title_short Effect of Interventricular Electrical Delay on Atrioventricular Optimization for Cardiac Resynchronization Therapy
title_sort effect of interventricular electrical delay on atrioventricular optimization for cardiac resynchronization therapy
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6110372/
https://www.ncbi.nlm.nih.gov/pubmed/30354310
http://dx.doi.org/10.1161/CIRCEP.117.006055
work_keys_str_mv AT goldmichaelr effectofinterventricularelectricaldelayonatrioventricularoptimizationforcardiacresynchronizationtherapy
AT yuyinghong effectofinterventricularelectricaldelayonatrioventricularoptimizationforcardiacresynchronizationtherapy
AT singhjagmeetp effectofinterventricularelectricaldelayonatrioventricularoptimizationforcardiacresynchronizationtherapy
AT birgersdottergreenulrika effectofinterventricularelectricaldelayonatrioventricularoptimizationforcardiacresynchronizationtherapy
AT steinkennethm effectofinterventricularelectricaldelayonatrioventricularoptimizationforcardiacresynchronizationtherapy
AT woldnicholas effectofinterventricularelectricaldelayonatrioventricularoptimizationforcardiacresynchronizationtherapy
AT meyertimothye effectofinterventricularelectricaldelayonatrioventricularoptimizationforcardiacresynchronizationtherapy
AT ellenbogenkennetha effectofinterventricularelectricaldelayonatrioventricularoptimizationforcardiacresynchronizationtherapy