Cargando…
Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement
In this article, an approach to designing and developing an ultrahigh frequency (≤600 MHz) ultrasound analog frontend with Golay coded excitation sequence for high resolution imaging applications is presented. For the purpose of visualizing specific structures or measuring functional responses of mi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111284/ https://www.ncbi.nlm.nih.gov/pubmed/30096810 http://dx.doi.org/10.3390/s18082598 |
_version_ | 1783350624967983104 |
---|---|
author | Kim, Min Gon Park, Jinhyoung Zhou, Qifa Shung, Koping Kirk |
author_facet | Kim, Min Gon Park, Jinhyoung Zhou, Qifa Shung, Koping Kirk |
author_sort | Kim, Min Gon |
collection | PubMed |
description | In this article, an approach to designing and developing an ultrahigh frequency (≤600 MHz) ultrasound analog frontend with Golay coded excitation sequence for high resolution imaging applications is presented. For the purpose of visualizing specific structures or measuring functional responses of micron-sized biological samples, a higher frequency ultrasound is needed to obtain a decent spatial resolution while it lowers the signal-to-noise ratio, the difference in decibels between the signal level and the background noise level, due to the higher attenuation coefficient. In order to enhance the signal-to-noise ratio, conventional approach was to increase the transmit voltage level. However, it may cause damaging the extremely thin piezoelectric material in the ultrahigh frequency range. In this paper, we present a novel design of ultrahigh frequency (≤600 MHz) frontend system capable of performing pseudo Golay coded excitation by configuring four independently operating pulse generators in parallel and the consecutive delayed transmission from each channel. Compared with the conventional monocycle pulse approach, the signal-to-noise ratio of the proposed approach was improved by 7–9 dB without compromising the spatial resolution. The measured axial and lateral resolutions of wire targets were 16.4 µm and 10.6 µm by using 156 MHz 4 bit pseudo Golay coded excitation, respectively and 4.5 µm and 7.7 µm by using 312 MHz 4 bit pseudo Golay coded excitation, respectively. |
format | Online Article Text |
id | pubmed-6111284 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61112842018-08-30 Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement Kim, Min Gon Park, Jinhyoung Zhou, Qifa Shung, Koping Kirk Sensors (Basel) Article In this article, an approach to designing and developing an ultrahigh frequency (≤600 MHz) ultrasound analog frontend with Golay coded excitation sequence for high resolution imaging applications is presented. For the purpose of visualizing specific structures or measuring functional responses of micron-sized biological samples, a higher frequency ultrasound is needed to obtain a decent spatial resolution while it lowers the signal-to-noise ratio, the difference in decibels between the signal level and the background noise level, due to the higher attenuation coefficient. In order to enhance the signal-to-noise ratio, conventional approach was to increase the transmit voltage level. However, it may cause damaging the extremely thin piezoelectric material in the ultrahigh frequency range. In this paper, we present a novel design of ultrahigh frequency (≤600 MHz) frontend system capable of performing pseudo Golay coded excitation by configuring four independently operating pulse generators in parallel and the consecutive delayed transmission from each channel. Compared with the conventional monocycle pulse approach, the signal-to-noise ratio of the proposed approach was improved by 7–9 dB without compromising the spatial resolution. The measured axial and lateral resolutions of wire targets were 16.4 µm and 10.6 µm by using 156 MHz 4 bit pseudo Golay coded excitation, respectively and 4.5 µm and 7.7 µm by using 312 MHz 4 bit pseudo Golay coded excitation, respectively. MDPI 2018-08-08 /pmc/articles/PMC6111284/ /pubmed/30096810 http://dx.doi.org/10.3390/s18082598 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kim, Min Gon Park, Jinhyoung Zhou, Qifa Shung, Koping Kirk Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement |
title | Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement |
title_full | Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement |
title_fullStr | Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement |
title_full_unstemmed | Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement |
title_short | Novel Configurations of Ultrahigh Frequency (≤600 MHz) Analog Frontend for High Resolution Ultrasound Measurement |
title_sort | novel configurations of ultrahigh frequency (≤600 mhz) analog frontend for high resolution ultrasound measurement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111284/ https://www.ncbi.nlm.nih.gov/pubmed/30096810 http://dx.doi.org/10.3390/s18082598 |
work_keys_str_mv | AT kimmingon novelconfigurationsofultrahighfrequency600mhzanalogfrontendforhighresolutionultrasoundmeasurement AT parkjinhyoung novelconfigurationsofultrahighfrequency600mhzanalogfrontendforhighresolutionultrasoundmeasurement AT zhouqifa novelconfigurationsofultrahighfrequency600mhzanalogfrontendforhighresolutionultrasoundmeasurement AT shungkopingkirk novelconfigurationsofultrahighfrequency600mhzanalogfrontendforhighresolutionultrasoundmeasurement |