Cargando…

Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads

Different electrochemical strategies based on the use of magnetic beads are described in this work for the detection of human cardiac troponin I (hcTnI). hcTnI is also known as the gold standard for acute myocardial infarction (AMI) diagnosis according to the different guidelines from the European S...

Descripción completa

Detalles Bibliográficos
Autores principales: Hernández-Albors, Alejandro, Colom, Gloria, Salvador, J.-Pablo, Marco, M.-Pilar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111321/
https://www.ncbi.nlm.nih.gov/pubmed/30060625
http://dx.doi.org/10.3390/s18082457
_version_ 1783350633849421824
author Hernández-Albors, Alejandro
Colom, Gloria
Salvador, J.-Pablo
Marco, M.-Pilar
author_facet Hernández-Albors, Alejandro
Colom, Gloria
Salvador, J.-Pablo
Marco, M.-Pilar
author_sort Hernández-Albors, Alejandro
collection PubMed
description Different electrochemical strategies based on the use of magnetic beads are described in this work for the detection of human cardiac troponin I (hcTnI). hcTnI is also known as the gold standard for acute myocardial infarction (AMI) diagnosis according to the different guidelines from the European Society of Cardiology (ESC) and the American College of Cardiology (ACC). Amperometric and voltamperometric sandwich magnetoimmunoassays were developed by biofunctionalization of paramagnetic beads with specific antibodies. These bioconjugates were combined with biotinylated antibodies as detection antibodies, with the aim of testing different electrochemical transduction principles. Streptavidin labeled with horseradish peroxidase was used for the amperometric magnetoimmunoassay, reaching a detectability of 0.005 ± 0.002 µg mL(−1) in 30 min. Cadmium quantum dots-streptavidin bioconjugates were used in the case of the voltamperometric immunosensor reaching a detectability of 0.023 ± 0.014 µg mL(−1).
format Online
Article
Text
id pubmed-6111321
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61113212018-08-30 Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads Hernández-Albors, Alejandro Colom, Gloria Salvador, J.-Pablo Marco, M.-Pilar Sensors (Basel) Article Different electrochemical strategies based on the use of magnetic beads are described in this work for the detection of human cardiac troponin I (hcTnI). hcTnI is also known as the gold standard for acute myocardial infarction (AMI) diagnosis according to the different guidelines from the European Society of Cardiology (ESC) and the American College of Cardiology (ACC). Amperometric and voltamperometric sandwich magnetoimmunoassays were developed by biofunctionalization of paramagnetic beads with specific antibodies. These bioconjugates were combined with biotinylated antibodies as detection antibodies, with the aim of testing different electrochemical transduction principles. Streptavidin labeled with horseradish peroxidase was used for the amperometric magnetoimmunoassay, reaching a detectability of 0.005 ± 0.002 µg mL(−1) in 30 min. Cadmium quantum dots-streptavidin bioconjugates were used in the case of the voltamperometric immunosensor reaching a detectability of 0.023 ± 0.014 µg mL(−1). MDPI 2018-07-29 /pmc/articles/PMC6111321/ /pubmed/30060625 http://dx.doi.org/10.3390/s18082457 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hernández-Albors, Alejandro
Colom, Gloria
Salvador, J.-Pablo
Marco, M.-Pilar
Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads
title Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads
title_full Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads
title_fullStr Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads
title_full_unstemmed Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads
title_short Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads
title_sort studies towards hctni immunodetection using electrochemical approaches based on magnetic microbeads
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111321/
https://www.ncbi.nlm.nih.gov/pubmed/30060625
http://dx.doi.org/10.3390/s18082457
work_keys_str_mv AT hernandezalborsalejandro studiestowardshctniimmunodetectionusingelectrochemicalapproachesbasedonmagneticmicrobeads
AT colomgloria studiestowardshctniimmunodetectionusingelectrochemicalapproachesbasedonmagneticmicrobeads
AT salvadorjpablo studiestowardshctniimmunodetectionusingelectrochemicalapproachesbasedonmagneticmicrobeads
AT marcompilar studiestowardshctniimmunodetectionusingelectrochemicalapproachesbasedonmagneticmicrobeads