Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator

In this study, we study a heat transfer model, with the surface of the microbolometer device receiving radiation from blackbody constructed using a COMSOL Multiphysics simulator. We have proposed three kinds of L-type 2-leg and 4-leg with the pixel pitch of 35 μm based on vanadium oxide absorbent me...

Descripción completa

Detalles Bibliográficos
Autores principales: Deng, Yu-Zhen, Tang, Shiang-Feng, Zeng, Hong-Yuan, Wu, Zheng-Yuan, Tung, Der-Kuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111408/
https://www.ncbi.nlm.nih.gov/pubmed/30096759
http://dx.doi.org/10.3390/s18082593
_version_ 1783350654241079296
author Deng, Yu-Zhen
Tang, Shiang-Feng
Zeng, Hong-Yuan
Wu, Zheng-Yuan
Tung, Der-Kuo
author_facet Deng, Yu-Zhen
Tang, Shiang-Feng
Zeng, Hong-Yuan
Wu, Zheng-Yuan
Tung, Der-Kuo
author_sort Deng, Yu-Zhen
collection PubMed
description In this study, we study a heat transfer model, with the surface of the microbolometer device receiving radiation from blackbody constructed using a COMSOL Multiphysics simulator. We have proposed three kinds of L-type 2-leg and 4-leg with the pixel pitch of 35 μm based on vanadium oxide absorbent membrane sandwiched with top passivated and bottom Si(3)N(4) supporting films, respectively. Under the blackbody radiation, the surface temperature changes and distributions of these samples are simulated and analyzed in detail. The trend of change of the temperature dependent resistance of the four kinds of bolometer devices using the proposed heat transfer model is consistent with the actual results of the change of resistance of 4 samples irradiated with 325 K blackbody located in the front distance of 5 cm. In this paper, ΔT indicates the averaged differences of the top temperature on the suspended membrane and the lowest temperature on the post of legs of the microbolometers. It is shown that ΔT ≈ 17 mK is larger in nominal 2-leg microbolometer device than that of 4-leg one and of 2-leg with 2 μm × 2 μm central square hole and two 7.5 μm × 2 μm slits in suspended films. Additionally, only ΔT ≈ 5 mK with 4-leg microbolometer device under the same radiated energy of 325 K blackbody results from the larger total thermal conductance.
format Online
Article
Text
id pubmed-6111408
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61114082018-08-30 Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator Deng, Yu-Zhen Tang, Shiang-Feng Zeng, Hong-Yuan Wu, Zheng-Yuan Tung, Der-Kuo Sensors (Basel) Article In this study, we study a heat transfer model, with the surface of the microbolometer device receiving radiation from blackbody constructed using a COMSOL Multiphysics simulator. We have proposed three kinds of L-type 2-leg and 4-leg with the pixel pitch of 35 μm based on vanadium oxide absorbent membrane sandwiched with top passivated and bottom Si(3)N(4) supporting films, respectively. Under the blackbody radiation, the surface temperature changes and distributions of these samples are simulated and analyzed in detail. The trend of change of the temperature dependent resistance of the four kinds of bolometer devices using the proposed heat transfer model is consistent with the actual results of the change of resistance of 4 samples irradiated with 325 K blackbody located in the front distance of 5 cm. In this paper, ΔT indicates the averaged differences of the top temperature on the suspended membrane and the lowest temperature on the post of legs of the microbolometers. It is shown that ΔT ≈ 17 mK is larger in nominal 2-leg microbolometer device than that of 4-leg one and of 2-leg with 2 μm × 2 μm central square hole and two 7.5 μm × 2 μm slits in suspended films. Additionally, only ΔT ≈ 5 mK with 4-leg microbolometer device under the same radiated energy of 325 K blackbody results from the larger total thermal conductance. MDPI 2018-08-08 /pmc/articles/PMC6111408/ /pubmed/30096759 http://dx.doi.org/10.3390/s18082593 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Deng, Yu-Zhen
Tang, Shiang-Feng
Zeng, Hong-Yuan
Wu, Zheng-Yuan
Tung, Der-Kuo
Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator
title Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator
title_full Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator
title_fullStr Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator
title_full_unstemmed Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator
title_short Experiments on Temperature Changes of Microbolometer under Blackbody Radiation and Predictions Using Thermal Modeling by COMSOL Multiphysics Simulator
title_sort experiments on temperature changes of microbolometer under blackbody radiation and predictions using thermal modeling by comsol multiphysics simulator
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111408/
https://www.ncbi.nlm.nih.gov/pubmed/30096759
http://dx.doi.org/10.3390/s18082593
work_keys_str_mv AT dengyuzhen experimentsontemperaturechangesofmicrobolometerunderblackbodyradiationandpredictionsusingthermalmodelingbycomsolmultiphysicssimulator
AT tangshiangfeng experimentsontemperaturechangesofmicrobolometerunderblackbodyradiationandpredictionsusingthermalmodelingbycomsolmultiphysicssimulator
AT zenghongyuan experimentsontemperaturechangesofmicrobolometerunderblackbodyradiationandpredictionsusingthermalmodelingbycomsolmultiphysicssimulator
AT wuzhengyuan experimentsontemperaturechangesofmicrobolometerunderblackbodyradiationandpredictionsusingthermalmodelingbycomsolmultiphysicssimulator
AT tungderkuo experimentsontemperaturechangesofmicrobolometerunderblackbodyradiationandpredictionsusingthermalmodelingbycomsolmultiphysicssimulator