Cargando…
High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach–Zehnder Interferometers
A temperature multipoint sensing system based on three cascade Mach–Zehnder interferometers (MZIs) is introduced. The MZIs with different lengths are fabricated based on waist-enlarged fiber bitapers. The fast Fourier transformation is applied to the overlapping transmission spectrum and the corresp...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111578/ https://www.ncbi.nlm.nih.gov/pubmed/30115819 http://dx.doi.org/10.3390/s18082688 |
_version_ | 1783350682291535872 |
---|---|
author | Zhao, Na Lin, Qijing Jiang, Zhuangde Yao, Kun Tian, Bian Fang, Xudong Shi, Peng Zhang, Zhongkai |
author_facet | Zhao, Na Lin, Qijing Jiang, Zhuangde Yao, Kun Tian, Bian Fang, Xudong Shi, Peng Zhang, Zhongkai |
author_sort | Zhao, Na |
collection | PubMed |
description | A temperature multipoint sensing system based on three cascade Mach–Zehnder interferometers (MZIs) is introduced. The MZIs with different lengths are fabricated based on waist-enlarged fiber bitapers. The fast Fourier transformation is applied to the overlapping transmission spectrum and the corresponding interference spectra can be obtained via the cascaded frequency spectrum based on the inverse Fourier transformation. By analyzing the drift of interference spectra, the temperature response sensitivities of 0.063 nm/°C, 0.071 nm/°C, and 0.059 nm/°C in different furnaces can be detected from room temperature up to 1000 °C, and the temperature response at different regions can be measured through the sensitivity matrix equation. These results demonstrate feasibility of multipoint measurement, which also support that the temperature sensing system provides new solution to the MZI cascade problem. |
format | Online Article Text |
id | pubmed-6111578 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61115782018-08-30 High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach–Zehnder Interferometers Zhao, Na Lin, Qijing Jiang, Zhuangde Yao, Kun Tian, Bian Fang, Xudong Shi, Peng Zhang, Zhongkai Sensors (Basel) Article A temperature multipoint sensing system based on three cascade Mach–Zehnder interferometers (MZIs) is introduced. The MZIs with different lengths are fabricated based on waist-enlarged fiber bitapers. The fast Fourier transformation is applied to the overlapping transmission spectrum and the corresponding interference spectra can be obtained via the cascaded frequency spectrum based on the inverse Fourier transformation. By analyzing the drift of interference spectra, the temperature response sensitivities of 0.063 nm/°C, 0.071 nm/°C, and 0.059 nm/°C in different furnaces can be detected from room temperature up to 1000 °C, and the temperature response at different regions can be measured through the sensitivity matrix equation. These results demonstrate feasibility of multipoint measurement, which also support that the temperature sensing system provides new solution to the MZI cascade problem. MDPI 2018-08-16 /pmc/articles/PMC6111578/ /pubmed/30115819 http://dx.doi.org/10.3390/s18082688 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhao, Na Lin, Qijing Jiang, Zhuangde Yao, Kun Tian, Bian Fang, Xudong Shi, Peng Zhang, Zhongkai High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach–Zehnder Interferometers |
title | High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach–Zehnder Interferometers |
title_full | High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach–Zehnder Interferometers |
title_fullStr | High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach–Zehnder Interferometers |
title_full_unstemmed | High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach–Zehnder Interferometers |
title_short | High Temperature High Sensitivity Multipoint Sensing System Based on Three Cascade Mach–Zehnder Interferometers |
title_sort | high temperature high sensitivity multipoint sensing system based on three cascade mach–zehnder interferometers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111578/ https://www.ncbi.nlm.nih.gov/pubmed/30115819 http://dx.doi.org/10.3390/s18082688 |
work_keys_str_mv | AT zhaona hightemperaturehighsensitivitymultipointsensingsystembasedonthreecascademachzehnderinterferometers AT linqijing hightemperaturehighsensitivitymultipointsensingsystembasedonthreecascademachzehnderinterferometers AT jiangzhuangde hightemperaturehighsensitivitymultipointsensingsystembasedonthreecascademachzehnderinterferometers AT yaokun hightemperaturehighsensitivitymultipointsensingsystembasedonthreecascademachzehnderinterferometers AT tianbian hightemperaturehighsensitivitymultipointsensingsystembasedonthreecascademachzehnderinterferometers AT fangxudong hightemperaturehighsensitivitymultipointsensingsystembasedonthreecascademachzehnderinterferometers AT shipeng hightemperaturehighsensitivitymultipointsensingsystembasedonthreecascademachzehnderinterferometers AT zhangzhongkai hightemperaturehighsensitivitymultipointsensingsystembasedonthreecascademachzehnderinterferometers |