Cargando…

0.6 V, 116 nW Neural Spike Acquisition IC with Self-Biased Instrumentation Amplifier and Analog Spike Extraction

This paper presents an ultralow power 0.6 V 116 nW neural spike acquisition integrated circuit with analog spike extraction. To reduce power consumption, an ultralow power self-biased current-balanced instrumentation amplifier (IA) is proposed. The passive RC lowpass filter in the amplifier acts as...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jong Pal, Lee, Hankyu, Ko, Hyoungho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111709/
https://www.ncbi.nlm.nih.gov/pubmed/30061480
http://dx.doi.org/10.3390/s18082460
_version_ 1783350713127010304
author Kim, Jong Pal
Lee, Hankyu
Ko, Hyoungho
author_facet Kim, Jong Pal
Lee, Hankyu
Ko, Hyoungho
author_sort Kim, Jong Pal
collection PubMed
description This paper presents an ultralow power 0.6 V 116 nW neural spike acquisition integrated circuit with analog spike extraction. To reduce power consumption, an ultralow power self-biased current-balanced instrumentation amplifier (IA) is proposed. The passive RC lowpass filter in the amplifier acts as both DC servo loop and self-bias circuit. The spike detector, based on an analog nonlinear energy operator consisting of a low-voltage open-loop differentiator and an open-loop gate-bulk input multiplier, is designed to emphasize the high frequency spike components nonlinearly. To reduce the spike detection error, the adjacent spike merger is also proposed. The proposed circuit achieves a low IA current consumption of 46.4 nA at 0.6 V, noise efficiency factor (NEF) of 1.81, the bandwidth from 102 Hz to 1.94 kHz, the input referred noise of 9.37 μVrms, and overall power consumption of 116 nW at 0.6 V. The proposed circuit can be used in the ultralow power spike pulses acquisition applications, including the neurofeedback systems on peripheral nerves with low neuron density.
format Online
Article
Text
id pubmed-6111709
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61117092018-08-30 0.6 V, 116 nW Neural Spike Acquisition IC with Self-Biased Instrumentation Amplifier and Analog Spike Extraction Kim, Jong Pal Lee, Hankyu Ko, Hyoungho Sensors (Basel) Article This paper presents an ultralow power 0.6 V 116 nW neural spike acquisition integrated circuit with analog spike extraction. To reduce power consumption, an ultralow power self-biased current-balanced instrumentation amplifier (IA) is proposed. The passive RC lowpass filter in the amplifier acts as both DC servo loop and self-bias circuit. The spike detector, based on an analog nonlinear energy operator consisting of a low-voltage open-loop differentiator and an open-loop gate-bulk input multiplier, is designed to emphasize the high frequency spike components nonlinearly. To reduce the spike detection error, the adjacent spike merger is also proposed. The proposed circuit achieves a low IA current consumption of 46.4 nA at 0.6 V, noise efficiency factor (NEF) of 1.81, the bandwidth from 102 Hz to 1.94 kHz, the input referred noise of 9.37 μVrms, and overall power consumption of 116 nW at 0.6 V. The proposed circuit can be used in the ultralow power spike pulses acquisition applications, including the neurofeedback systems on peripheral nerves with low neuron density. MDPI 2018-07-30 /pmc/articles/PMC6111709/ /pubmed/30061480 http://dx.doi.org/10.3390/s18082460 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Jong Pal
Lee, Hankyu
Ko, Hyoungho
0.6 V, 116 nW Neural Spike Acquisition IC with Self-Biased Instrumentation Amplifier and Analog Spike Extraction
title 0.6 V, 116 nW Neural Spike Acquisition IC with Self-Biased Instrumentation Amplifier and Analog Spike Extraction
title_full 0.6 V, 116 nW Neural Spike Acquisition IC with Self-Biased Instrumentation Amplifier and Analog Spike Extraction
title_fullStr 0.6 V, 116 nW Neural Spike Acquisition IC with Self-Biased Instrumentation Amplifier and Analog Spike Extraction
title_full_unstemmed 0.6 V, 116 nW Neural Spike Acquisition IC with Self-Biased Instrumentation Amplifier and Analog Spike Extraction
title_short 0.6 V, 116 nW Neural Spike Acquisition IC with Self-Biased Instrumentation Amplifier and Analog Spike Extraction
title_sort 0.6 v, 116 nw neural spike acquisition ic with self-biased instrumentation amplifier and analog spike extraction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111709/
https://www.ncbi.nlm.nih.gov/pubmed/30061480
http://dx.doi.org/10.3390/s18082460
work_keys_str_mv AT kimjongpal 06v116nwneuralspikeacquisitionicwithselfbiasedinstrumentationamplifierandanalogspikeextraction
AT leehankyu 06v116nwneuralspikeacquisitionicwithselfbiasedinstrumentationamplifierandanalogspikeextraction
AT kohyoungho 06v116nwneuralspikeacquisitionicwithselfbiasedinstrumentationamplifierandanalogspikeextraction