Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology
As the development of modalities for prostate cancer (PCa) imaging advances, the challenge of accurate registration between images and histopathologic ground truth becomes more pressing. Localization of PCa, rather than detection, requires a pixel-to-pixel validation of imaging based on histopatholo...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6113189/ https://www.ncbi.nlm.nih.gov/pubmed/30062440 http://dx.doi.org/10.1007/s40477-018-0311-8 |
_version_ | 1783350965381890048 |
---|---|
author | Wildeboer, Rogier R. van Sloun, Ruud J.G. Postema, Arnoud W. Mannaerts, Christophe K. Gayet, Maudy Beerlage, Harrie P. Wijkstra, Hessel Mischi, Massimo |
author_facet | Wildeboer, Rogier R. van Sloun, Ruud J.G. Postema, Arnoud W. Mannaerts, Christophe K. Gayet, Maudy Beerlage, Harrie P. Wijkstra, Hessel Mischi, Massimo |
author_sort | Wildeboer, Rogier R. |
collection | PubMed |
description | As the development of modalities for prostate cancer (PCa) imaging advances, the challenge of accurate registration between images and histopathologic ground truth becomes more pressing. Localization of PCa, rather than detection, requires a pixel-to-pixel validation of imaging based on histopathology after radical prostatectomy. Such a registration procedure is challenging for ultrasound modalities; not only the deformations of the prostate after resection have to be taken into account, but also the deformation due to the employed transrectal probe and the mismatch in orientation between imaging planes and pathology slices. In this work, we review the latest techniques to facilitate accurate validation of PCa localization in ultrasound imaging studies and extrapolate a general strategy for implementation of a registration procedure. |
format | Online Article Text |
id | pubmed-6113189 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-61131892018-08-31 Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology Wildeboer, Rogier R. van Sloun, Ruud J.G. Postema, Arnoud W. Mannaerts, Christophe K. Gayet, Maudy Beerlage, Harrie P. Wijkstra, Hessel Mischi, Massimo J Ultrasound Review As the development of modalities for prostate cancer (PCa) imaging advances, the challenge of accurate registration between images and histopathologic ground truth becomes more pressing. Localization of PCa, rather than detection, requires a pixel-to-pixel validation of imaging based on histopathology after radical prostatectomy. Such a registration procedure is challenging for ultrasound modalities; not only the deformations of the prostate after resection have to be taken into account, but also the deformation due to the employed transrectal probe and the mismatch in orientation between imaging planes and pathology slices. In this work, we review the latest techniques to facilitate accurate validation of PCa localization in ultrasound imaging studies and extrapolate a general strategy for implementation of a registration procedure. Springer International Publishing 2018-07-30 /pmc/articles/PMC6113189/ /pubmed/30062440 http://dx.doi.org/10.1007/s40477-018-0311-8 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Review Wildeboer, Rogier R. van Sloun, Ruud J.G. Postema, Arnoud W. Mannaerts, Christophe K. Gayet, Maudy Beerlage, Harrie P. Wijkstra, Hessel Mischi, Massimo Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology |
title | Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology |
title_full | Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology |
title_fullStr | Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology |
title_full_unstemmed | Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology |
title_short | Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology |
title_sort | accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6113189/ https://www.ncbi.nlm.nih.gov/pubmed/30062440 http://dx.doi.org/10.1007/s40477-018-0311-8 |
work_keys_str_mv | AT wildeboerrogierr accuratevalidationofultrasoundimagingofprostatecancerareviewofchallengesinregistrationofimagingandhistopathology AT vanslounruudjg accuratevalidationofultrasoundimagingofprostatecancerareviewofchallengesinregistrationofimagingandhistopathology AT postemaarnoudw accuratevalidationofultrasoundimagingofprostatecancerareviewofchallengesinregistrationofimagingandhistopathology AT mannaertschristophek accuratevalidationofultrasoundimagingofprostatecancerareviewofchallengesinregistrationofimagingandhistopathology AT gayetmaudy accuratevalidationofultrasoundimagingofprostatecancerareviewofchallengesinregistrationofimagingandhistopathology AT beerlageharriep accuratevalidationofultrasoundimagingofprostatecancerareviewofchallengesinregistrationofimagingandhistopathology AT wijkstrahessel accuratevalidationofultrasoundimagingofprostatecancerareviewofchallengesinregistrationofimagingandhistopathology AT mischimassimo accuratevalidationofultrasoundimagingofprostatecancerareviewofchallengesinregistrationofimagingandhistopathology |