Cargando…
Correlation of Color Fundus Photograph Grading with Risks of Early Age-related Macular Degeneration by using Automated OCT-derived Drusen Measurements
We evaluated automated OCT-derived drusen volume measures in a population-based study (n = 4,512) aged ≥40 years, and its correlation with conventional color fundus photographs (CFP)-derived early AMD features. Participants had protocol-based assessment to capture medical and ocular history, genotyp...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6113205/ https://www.ncbi.nlm.nih.gov/pubmed/30154521 http://dx.doi.org/10.1038/s41598-018-31109-x |
_version_ | 1783350968666030080 |
---|---|
author | Cheung, Chui Ming Gemmy Shi, Yuan Tham, Yih Chung Sabanayagam, Charumathi Neelam, Kumari Wang, Jie Jin Mitchell, Paul Cheng, Ching-Yu Wong, Tien Yin Cheung, Carol Yim Lui |
author_facet | Cheung, Chui Ming Gemmy Shi, Yuan Tham, Yih Chung Sabanayagam, Charumathi Neelam, Kumari Wang, Jie Jin Mitchell, Paul Cheng, Ching-Yu Wong, Tien Yin Cheung, Carol Yim Lui |
author_sort | Cheung, Chui Ming Gemmy |
collection | PubMed |
description | We evaluated automated OCT-derived drusen volume measures in a population-based study (n = 4,512) aged ≥40 years, and its correlation with conventional color fundus photographs (CFP)-derived early AMD features. Participants had protocol-based assessment to capture medical and ocular history, genotyping for SNPs in CFH, ARMS2, and CETP, CFP-based AMD grading and automated drusen volume based on SD-OCT using built-in software (Cirrus OCT advanced RPE analysis software). Significantly fewer eyes with early AMD features (drusen, hyperpigmentation, soft or reticular drusen) had drusen volume = 0 mm(3) (p < 0.001). In eyes with drusen volume > 0 mm(3), increasing AMD severity was associated with increase in drusen volume (correlation coefficient 0.17, p < 0.001). However 220 (59.14%) of 372 participants with AMD based on CFP grading had drusen volume = 0 mm(3). Factors associated with drusen volume included age (OR 1.42 per 5 years, 95% confidence interval [CI] 2.76, 4.48), systolic blood pressure (OR1.00, 95% CI 1.00, 1.01), ethnic Malay (OR 1.54, 95% CI 1.29, 1.83) and Chinese (OR 1.66, 95% CI 1.37, 2.01) compared to Indian. The ARMS2 rs10490924 T allele was associated with increased drusen volume in subjects with AMD (multivariable adjusted OR1.54, 95% CI 1.08, 2.19). Automated OCT-derived drusen volume is correlated with CFP-based AMD grading in many, but not all subjects. However the agreement is not good. These two modalities provide complementary information and should be incorporated into future studies. |
format | Online Article Text |
id | pubmed-6113205 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-61132052018-08-30 Correlation of Color Fundus Photograph Grading with Risks of Early Age-related Macular Degeneration by using Automated OCT-derived Drusen Measurements Cheung, Chui Ming Gemmy Shi, Yuan Tham, Yih Chung Sabanayagam, Charumathi Neelam, Kumari Wang, Jie Jin Mitchell, Paul Cheng, Ching-Yu Wong, Tien Yin Cheung, Carol Yim Lui Sci Rep Article We evaluated automated OCT-derived drusen volume measures in a population-based study (n = 4,512) aged ≥40 years, and its correlation with conventional color fundus photographs (CFP)-derived early AMD features. Participants had protocol-based assessment to capture medical and ocular history, genotyping for SNPs in CFH, ARMS2, and CETP, CFP-based AMD grading and automated drusen volume based on SD-OCT using built-in software (Cirrus OCT advanced RPE analysis software). Significantly fewer eyes with early AMD features (drusen, hyperpigmentation, soft or reticular drusen) had drusen volume = 0 mm(3) (p < 0.001). In eyes with drusen volume > 0 mm(3), increasing AMD severity was associated with increase in drusen volume (correlation coefficient 0.17, p < 0.001). However 220 (59.14%) of 372 participants with AMD based on CFP grading had drusen volume = 0 mm(3). Factors associated with drusen volume included age (OR 1.42 per 5 years, 95% confidence interval [CI] 2.76, 4.48), systolic blood pressure (OR1.00, 95% CI 1.00, 1.01), ethnic Malay (OR 1.54, 95% CI 1.29, 1.83) and Chinese (OR 1.66, 95% CI 1.37, 2.01) compared to Indian. The ARMS2 rs10490924 T allele was associated with increased drusen volume in subjects with AMD (multivariable adjusted OR1.54, 95% CI 1.08, 2.19). Automated OCT-derived drusen volume is correlated with CFP-based AMD grading in many, but not all subjects. However the agreement is not good. These two modalities provide complementary information and should be incorporated into future studies. Nature Publishing Group UK 2018-08-28 /pmc/articles/PMC6113205/ /pubmed/30154521 http://dx.doi.org/10.1038/s41598-018-31109-x Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Cheung, Chui Ming Gemmy Shi, Yuan Tham, Yih Chung Sabanayagam, Charumathi Neelam, Kumari Wang, Jie Jin Mitchell, Paul Cheng, Ching-Yu Wong, Tien Yin Cheung, Carol Yim Lui Correlation of Color Fundus Photograph Grading with Risks of Early Age-related Macular Degeneration by using Automated OCT-derived Drusen Measurements |
title | Correlation of Color Fundus Photograph Grading with Risks of Early Age-related Macular Degeneration by using Automated OCT-derived Drusen Measurements |
title_full | Correlation of Color Fundus Photograph Grading with Risks of Early Age-related Macular Degeneration by using Automated OCT-derived Drusen Measurements |
title_fullStr | Correlation of Color Fundus Photograph Grading with Risks of Early Age-related Macular Degeneration by using Automated OCT-derived Drusen Measurements |
title_full_unstemmed | Correlation of Color Fundus Photograph Grading with Risks of Early Age-related Macular Degeneration by using Automated OCT-derived Drusen Measurements |
title_short | Correlation of Color Fundus Photograph Grading with Risks of Early Age-related Macular Degeneration by using Automated OCT-derived Drusen Measurements |
title_sort | correlation of color fundus photograph grading with risks of early age-related macular degeneration by using automated oct-derived drusen measurements |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6113205/ https://www.ncbi.nlm.nih.gov/pubmed/30154521 http://dx.doi.org/10.1038/s41598-018-31109-x |
work_keys_str_mv | AT cheungchuiminggemmy correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT shiyuan correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT thamyihchung correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT sabanayagamcharumathi correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT neelamkumari correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT wangjiejin correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT mitchellpaul correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT chengchingyu correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT wongtienyin correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements AT cheungcarolyimlui correlationofcolorfundusphotographgradingwithrisksofearlyagerelatedmaculardegenerationbyusingautomatedoctderiveddrusenmeasurements |