Handheld Retinal Oximetry in Healthy Young Adults

PURPOSE: The objective of this study was to measure the relative retinal oxygen saturation with a prototype, mobile handheld oximeter in upright and supine position and to compare these measurements to the gold standard Oxymap T1 retinal oximeter in upright position. A handheld oximeter is needed fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Vehmeijer, Wouter, Hardarson, Sveinn Hakon, Jonkman, Kelly, Aarts, Leon, Dahan, Albert, Stefánsson, Einar, Schalij-Delfos, Nicoline
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6114026/
https://www.ncbi.nlm.nih.gov/pubmed/30174997
http://dx.doi.org/10.1167/tvst.7.4.19
_version_ 1783351118657486848
author Vehmeijer, Wouter
Hardarson, Sveinn Hakon
Jonkman, Kelly
Aarts, Leon
Dahan, Albert
Stefánsson, Einar
Schalij-Delfos, Nicoline
author_facet Vehmeijer, Wouter
Hardarson, Sveinn Hakon
Jonkman, Kelly
Aarts, Leon
Dahan, Albert
Stefánsson, Einar
Schalij-Delfos, Nicoline
author_sort Vehmeijer, Wouter
collection PubMed
description PURPOSE: The objective of this study was to measure the relative retinal oxygen saturation with a prototype, mobile handheld oximeter in upright and supine position and to compare these measurements to the gold standard Oxymap T1 retinal oximeter in upright position. A handheld oximeter is needed for measurements of infants with retinopathy of prematurity as well as acutely injured and bedridden adults. METHODS: Healthy volunteers (age 18–35) were recruited at the Leiden University Medical Center. Retinal images were acquired with the handheld oximeter and the Oxymap T1. Both cameras are dual-wavelength oximeters and acquire images with wavelengths of 570 and 600 nm. Retinal oxygen saturation values were determined for both the handheld camera and the Oxymap T1. RESULTS: Twenty-one subjects (age 25 ± 2 years) were included. In upright position, the oxygen saturation for the arterioles was 92.2% to 4.9% vs. 95.5% ± 4.2% and for the venules 57.9% ± 10.2% vs. 57.7% ± 6.4% for the handheld camera and Oxymap T1, respectively. The oxygen saturation was higher in the arterioles than the venules for both cameras (P < 0.05). In supine position, measured with the handheld oximeter, the oxygen saturation in the arterioles was 92.3% ± 5.8% and 59.2% ± 6.1% in the venules. CONCLUSIONS: Performance of the prototype, mobile handheld oximeter Corimap camera compares well with the Oxymap T1, with a slightly larger standard deviation in oxygen saturation measurements, both in upright and supine patients. TRANSLATION RELEVANCE: To date, to our knowledge, no oximeters are available for handheld use and for measurement in supine position in infants and bedridden adults. Here we tested such an oximeter and show that its performance compares well with that of the gold standard Oxymap T1 in healthy adults.
format Online
Article
Text
id pubmed-6114026
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-61140262018-08-31 Handheld Retinal Oximetry in Healthy Young Adults Vehmeijer, Wouter Hardarson, Sveinn Hakon Jonkman, Kelly Aarts, Leon Dahan, Albert Stefánsson, Einar Schalij-Delfos, Nicoline Transl Vis Sci Technol Articles PURPOSE: The objective of this study was to measure the relative retinal oxygen saturation with a prototype, mobile handheld oximeter in upright and supine position and to compare these measurements to the gold standard Oxymap T1 retinal oximeter in upright position. A handheld oximeter is needed for measurements of infants with retinopathy of prematurity as well as acutely injured and bedridden adults. METHODS: Healthy volunteers (age 18–35) were recruited at the Leiden University Medical Center. Retinal images were acquired with the handheld oximeter and the Oxymap T1. Both cameras are dual-wavelength oximeters and acquire images with wavelengths of 570 and 600 nm. Retinal oxygen saturation values were determined for both the handheld camera and the Oxymap T1. RESULTS: Twenty-one subjects (age 25 ± 2 years) were included. In upright position, the oxygen saturation for the arterioles was 92.2% to 4.9% vs. 95.5% ± 4.2% and for the venules 57.9% ± 10.2% vs. 57.7% ± 6.4% for the handheld camera and Oxymap T1, respectively. The oxygen saturation was higher in the arterioles than the venules for both cameras (P < 0.05). In supine position, measured with the handheld oximeter, the oxygen saturation in the arterioles was 92.3% ± 5.8% and 59.2% ± 6.1% in the venules. CONCLUSIONS: Performance of the prototype, mobile handheld oximeter Corimap camera compares well with the Oxymap T1, with a slightly larger standard deviation in oxygen saturation measurements, both in upright and supine patients. TRANSLATION RELEVANCE: To date, to our knowledge, no oximeters are available for handheld use and for measurement in supine position in infants and bedridden adults. Here we tested such an oximeter and show that its performance compares well with that of the gold standard Oxymap T1 in healthy adults. The Association for Research in Vision and Ophthalmology 2018-08-27 /pmc/articles/PMC6114026/ /pubmed/30174997 http://dx.doi.org/10.1167/tvst.7.4.19 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Vehmeijer, Wouter
Hardarson, Sveinn Hakon
Jonkman, Kelly
Aarts, Leon
Dahan, Albert
Stefánsson, Einar
Schalij-Delfos, Nicoline
Handheld Retinal Oximetry in Healthy Young Adults
title Handheld Retinal Oximetry in Healthy Young Adults
title_full Handheld Retinal Oximetry in Healthy Young Adults
title_fullStr Handheld Retinal Oximetry in Healthy Young Adults
title_full_unstemmed Handheld Retinal Oximetry in Healthy Young Adults
title_short Handheld Retinal Oximetry in Healthy Young Adults
title_sort handheld retinal oximetry in healthy young adults
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6114026/
https://www.ncbi.nlm.nih.gov/pubmed/30174997
http://dx.doi.org/10.1167/tvst.7.4.19
work_keys_str_mv AT vehmeijerwouter handheldretinaloximetryinhealthyyoungadults
AT hardarsonsveinnhakon handheldretinaloximetryinhealthyyoungadults
AT jonkmankelly handheldretinaloximetryinhealthyyoungadults
AT aartsleon handheldretinaloximetryinhealthyyoungadults
AT dahanalbert handheldretinaloximetryinhealthyyoungadults
AT stefanssoneinar handheldretinaloximetryinhealthyyoungadults
AT schalijdelfosnicoline handheldretinaloximetryinhealthyyoungadults