Cargando…

Refractory macular hole repaired by autologous retinal graft and blood clot

BACKGROUND: To evaluate the surgical technique using autologous retinal graft (ARG) and autologous blood clot (ABC) for the management of refractory macular holes (MHs). METHODS: This study was a retrospective, consecutive, interventional case series. Six eyes of 6 patients who underwent vitrectomy...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, An-Lun, Chuang, Lan-Hsin, Wang, Nan-Kai, Chen, Kuan-Jen, Liu, Laura, Yeung, Ling, Chen, Tun-Lu, Hwang, Yih-Shiou, Wu, Wei-Chi, Lai, Chi-Chun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6114829/
https://www.ncbi.nlm.nih.gov/pubmed/30157808
http://dx.doi.org/10.1186/s12886-018-0898-8
_version_ 1783351266323202048
author Wu, An-Lun
Chuang, Lan-Hsin
Wang, Nan-Kai
Chen, Kuan-Jen
Liu, Laura
Yeung, Ling
Chen, Tun-Lu
Hwang, Yih-Shiou
Wu, Wei-Chi
Lai, Chi-Chun
author_facet Wu, An-Lun
Chuang, Lan-Hsin
Wang, Nan-Kai
Chen, Kuan-Jen
Liu, Laura
Yeung, Ling
Chen, Tun-Lu
Hwang, Yih-Shiou
Wu, Wei-Chi
Lai, Chi-Chun
author_sort Wu, An-Lun
collection PubMed
description BACKGROUND: To evaluate the surgical technique using autologous retinal graft (ARG) and autologous blood clot (ABC) for the management of refractory macular holes (MHs). METHODS: This study was a retrospective, consecutive, interventional case series. Six eyes of 6 patients who underwent vitrectomy combined with ARG and ABC for the treatment of refractory MH were reviewed. Visual and anatomic outcomes were evaluated. RESULTS: The mean age was 59.0 ± 9.9 years. All cases had multiple vitreoretinal procedures including vitrectomy and gas fluid exchange before patient presentation. The average numbers of vitrectomies were 2.3 ± 0.5, and those of gas fluid exchange were 3 ± 1.7. Closure of the macular hole was achieved in four (66.7%) cases at last follow-up. The mean follow-up time was 25.2 ± 15.6 months. The averaged BCVA before and after 12 months of the surgery improved from 20/591 to 20/244. CONCLUSIONS: This surgical technique using ARG and ABC provide an option for the treatment of refractory MHs. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12886-018-0898-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6114829
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-61148292018-09-04 Refractory macular hole repaired by autologous retinal graft and blood clot Wu, An-Lun Chuang, Lan-Hsin Wang, Nan-Kai Chen, Kuan-Jen Liu, Laura Yeung, Ling Chen, Tun-Lu Hwang, Yih-Shiou Wu, Wei-Chi Lai, Chi-Chun BMC Ophthalmol Research Article BACKGROUND: To evaluate the surgical technique using autologous retinal graft (ARG) and autologous blood clot (ABC) for the management of refractory macular holes (MHs). METHODS: This study was a retrospective, consecutive, interventional case series. Six eyes of 6 patients who underwent vitrectomy combined with ARG and ABC for the treatment of refractory MH were reviewed. Visual and anatomic outcomes were evaluated. RESULTS: The mean age was 59.0 ± 9.9 years. All cases had multiple vitreoretinal procedures including vitrectomy and gas fluid exchange before patient presentation. The average numbers of vitrectomies were 2.3 ± 0.5, and those of gas fluid exchange were 3 ± 1.7. Closure of the macular hole was achieved in four (66.7%) cases at last follow-up. The mean follow-up time was 25.2 ± 15.6 months. The averaged BCVA before and after 12 months of the surgery improved from 20/591 to 20/244. CONCLUSIONS: This surgical technique using ARG and ABC provide an option for the treatment of refractory MHs. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12886-018-0898-8) contains supplementary material, which is available to authorized users. BioMed Central 2018-08-29 /pmc/articles/PMC6114829/ /pubmed/30157808 http://dx.doi.org/10.1186/s12886-018-0898-8 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Wu, An-Lun
Chuang, Lan-Hsin
Wang, Nan-Kai
Chen, Kuan-Jen
Liu, Laura
Yeung, Ling
Chen, Tun-Lu
Hwang, Yih-Shiou
Wu, Wei-Chi
Lai, Chi-Chun
Refractory macular hole repaired by autologous retinal graft and blood clot
title Refractory macular hole repaired by autologous retinal graft and blood clot
title_full Refractory macular hole repaired by autologous retinal graft and blood clot
title_fullStr Refractory macular hole repaired by autologous retinal graft and blood clot
title_full_unstemmed Refractory macular hole repaired by autologous retinal graft and blood clot
title_short Refractory macular hole repaired by autologous retinal graft and blood clot
title_sort refractory macular hole repaired by autologous retinal graft and blood clot
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6114829/
https://www.ncbi.nlm.nih.gov/pubmed/30157808
http://dx.doi.org/10.1186/s12886-018-0898-8
work_keys_str_mv AT wuanlun refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT chuanglanhsin refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT wangnankai refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT chenkuanjen refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT liulaura refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT yeungling refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT chentunlu refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT hwangyihshiou refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT wuweichi refractorymacularholerepairedbyautologousretinalgraftandbloodclot
AT laichichun refractorymacularholerepairedbyautologousretinalgraftandbloodclot