Cargando…
Refractory macular hole repaired by autologous retinal graft and blood clot
BACKGROUND: To evaluate the surgical technique using autologous retinal graft (ARG) and autologous blood clot (ABC) for the management of refractory macular holes (MHs). METHODS: This study was a retrospective, consecutive, interventional case series. Six eyes of 6 patients who underwent vitrectomy...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6114829/ https://www.ncbi.nlm.nih.gov/pubmed/30157808 http://dx.doi.org/10.1186/s12886-018-0898-8 |
_version_ | 1783351266323202048 |
---|---|
author | Wu, An-Lun Chuang, Lan-Hsin Wang, Nan-Kai Chen, Kuan-Jen Liu, Laura Yeung, Ling Chen, Tun-Lu Hwang, Yih-Shiou Wu, Wei-Chi Lai, Chi-Chun |
author_facet | Wu, An-Lun Chuang, Lan-Hsin Wang, Nan-Kai Chen, Kuan-Jen Liu, Laura Yeung, Ling Chen, Tun-Lu Hwang, Yih-Shiou Wu, Wei-Chi Lai, Chi-Chun |
author_sort | Wu, An-Lun |
collection | PubMed |
description | BACKGROUND: To evaluate the surgical technique using autologous retinal graft (ARG) and autologous blood clot (ABC) for the management of refractory macular holes (MHs). METHODS: This study was a retrospective, consecutive, interventional case series. Six eyes of 6 patients who underwent vitrectomy combined with ARG and ABC for the treatment of refractory MH were reviewed. Visual and anatomic outcomes were evaluated. RESULTS: The mean age was 59.0 ± 9.9 years. All cases had multiple vitreoretinal procedures including vitrectomy and gas fluid exchange before patient presentation. The average numbers of vitrectomies were 2.3 ± 0.5, and those of gas fluid exchange were 3 ± 1.7. Closure of the macular hole was achieved in four (66.7%) cases at last follow-up. The mean follow-up time was 25.2 ± 15.6 months. The averaged BCVA before and after 12 months of the surgery improved from 20/591 to 20/244. CONCLUSIONS: This surgical technique using ARG and ABC provide an option for the treatment of refractory MHs. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12886-018-0898-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6114829 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-61148292018-09-04 Refractory macular hole repaired by autologous retinal graft and blood clot Wu, An-Lun Chuang, Lan-Hsin Wang, Nan-Kai Chen, Kuan-Jen Liu, Laura Yeung, Ling Chen, Tun-Lu Hwang, Yih-Shiou Wu, Wei-Chi Lai, Chi-Chun BMC Ophthalmol Research Article BACKGROUND: To evaluate the surgical technique using autologous retinal graft (ARG) and autologous blood clot (ABC) for the management of refractory macular holes (MHs). METHODS: This study was a retrospective, consecutive, interventional case series. Six eyes of 6 patients who underwent vitrectomy combined with ARG and ABC for the treatment of refractory MH were reviewed. Visual and anatomic outcomes were evaluated. RESULTS: The mean age was 59.0 ± 9.9 years. All cases had multiple vitreoretinal procedures including vitrectomy and gas fluid exchange before patient presentation. The average numbers of vitrectomies were 2.3 ± 0.5, and those of gas fluid exchange were 3 ± 1.7. Closure of the macular hole was achieved in four (66.7%) cases at last follow-up. The mean follow-up time was 25.2 ± 15.6 months. The averaged BCVA before and after 12 months of the surgery improved from 20/591 to 20/244. CONCLUSIONS: This surgical technique using ARG and ABC provide an option for the treatment of refractory MHs. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12886-018-0898-8) contains supplementary material, which is available to authorized users. BioMed Central 2018-08-29 /pmc/articles/PMC6114829/ /pubmed/30157808 http://dx.doi.org/10.1186/s12886-018-0898-8 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Wu, An-Lun Chuang, Lan-Hsin Wang, Nan-Kai Chen, Kuan-Jen Liu, Laura Yeung, Ling Chen, Tun-Lu Hwang, Yih-Shiou Wu, Wei-Chi Lai, Chi-Chun Refractory macular hole repaired by autologous retinal graft and blood clot |
title | Refractory macular hole repaired by autologous retinal graft and blood clot |
title_full | Refractory macular hole repaired by autologous retinal graft and blood clot |
title_fullStr | Refractory macular hole repaired by autologous retinal graft and blood clot |
title_full_unstemmed | Refractory macular hole repaired by autologous retinal graft and blood clot |
title_short | Refractory macular hole repaired by autologous retinal graft and blood clot |
title_sort | refractory macular hole repaired by autologous retinal graft and blood clot |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6114829/ https://www.ncbi.nlm.nih.gov/pubmed/30157808 http://dx.doi.org/10.1186/s12886-018-0898-8 |
work_keys_str_mv | AT wuanlun refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT chuanglanhsin refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT wangnankai refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT chenkuanjen refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT liulaura refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT yeungling refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT chentunlu refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT hwangyihshiou refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT wuweichi refractorymacularholerepairedbyautologousretinalgraftandbloodclot AT laichichun refractorymacularholerepairedbyautologousretinalgraftandbloodclot |