Cargando…
Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence
These imaging data are examples of sub-millimeter resolution T(1)-weighted EPI (Echo Planar Imaging) acquired using the T(1)23DEPI (T(1)-imaging with 2 3D-EPIs) sequence [1]; functional MRI data with matching resolution and distortion, and MP2RAGE (Magnetization Prepared 2 Rapid Acquisition Gradient...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6116420/ https://www.ncbi.nlm.nih.gov/pubmed/30175207 http://dx.doi.org/10.1016/j.dib.2018.08.030 |
_version_ | 1783351602335186944 |
---|---|
author | van der Zwaag, Wietske Buur, Pieter F. Fracasso, Alessio van Doesum, Tessa Uludağ, Kâmil Versluis, Maarten Marques, José P. |
author_facet | van der Zwaag, Wietske Buur, Pieter F. Fracasso, Alessio van Doesum, Tessa Uludağ, Kâmil Versluis, Maarten Marques, José P. |
author_sort | van der Zwaag, Wietske |
collection | PubMed |
description | These imaging data are examples of sub-millimeter resolution T(1)-weighted EPI (Echo Planar Imaging) acquired using the T(1)23DEPI (T(1)-imaging with 2 3D-EPIs) sequence [1]; functional MRI data with matching resolution and distortion, and MP2RAGE (Magnetization Prepared 2 Rapid Acquisition Gradient Echoes) anatomical images [2], from the same subjects. Data from two protocols and subjects presented in the paper describing the sequence [1] are made available here: 1).. 0.8 mm protocol: whole brain, axial T(1)23DEPI T(1)-weighted images; a 5-minute fMRI run with the same orientation and 27 mm coverage in the slice selection direction, covering the primary visual cortex. fMRI data were acquired while the volunteer viewed a flashing checkerboard stimulus; the unsmoothed GLM results of the fMRI and a 0.64 mm resolution MP2RAGE from the same subject. These data are from Experiment 3 in [1]; 2).. 0.7 mm protocol: partial brain T(1)23DEPI T(1)-weighted images with longer or shorter readouts; matching coronal echo planar images again acquired while viewing a flashing checkerboard stimulus and a 0.64 mm whole brain MP2RAGE from the same subject. These data are from Experiment 1 in [1]. |
format | Online Article Text |
id | pubmed-6116420 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-61164202018-08-31 Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence van der Zwaag, Wietske Buur, Pieter F. Fracasso, Alessio van Doesum, Tessa Uludağ, Kâmil Versluis, Maarten Marques, José P. Data Brief Neuroscience These imaging data are examples of sub-millimeter resolution T(1)-weighted EPI (Echo Planar Imaging) acquired using the T(1)23DEPI (T(1)-imaging with 2 3D-EPIs) sequence [1]; functional MRI data with matching resolution and distortion, and MP2RAGE (Magnetization Prepared 2 Rapid Acquisition Gradient Echoes) anatomical images [2], from the same subjects. Data from two protocols and subjects presented in the paper describing the sequence [1] are made available here: 1).. 0.8 mm protocol: whole brain, axial T(1)23DEPI T(1)-weighted images; a 5-minute fMRI run with the same orientation and 27 mm coverage in the slice selection direction, covering the primary visual cortex. fMRI data were acquired while the volunteer viewed a flashing checkerboard stimulus; the unsmoothed GLM results of the fMRI and a 0.64 mm resolution MP2RAGE from the same subject. These data are from Experiment 3 in [1]; 2).. 0.7 mm protocol: partial brain T(1)23DEPI T(1)-weighted images with longer or shorter readouts; matching coronal echo planar images again acquired while viewing a flashing checkerboard stimulus and a 0.64 mm whole brain MP2RAGE from the same subject. These data are from Experiment 1 in [1]. Elsevier 2018-08-16 /pmc/articles/PMC6116420/ /pubmed/30175207 http://dx.doi.org/10.1016/j.dib.2018.08.030 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Neuroscience van der Zwaag, Wietske Buur, Pieter F. Fracasso, Alessio van Doesum, Tessa Uludağ, Kâmil Versluis, Maarten Marques, José P. Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence |
title | Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence |
title_full | Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence |
title_fullStr | Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence |
title_full_unstemmed | Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence |
title_short | Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence |
title_sort | examples of sub-millimeter, 7t, t(1)-weighted epi datasets acquired with the t(1)23depi sequence |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6116420/ https://www.ncbi.nlm.nih.gov/pubmed/30175207 http://dx.doi.org/10.1016/j.dib.2018.08.030 |
work_keys_str_mv | AT vanderzwaagwietske examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence AT buurpieterf examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence AT fracassoalessio examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence AT vandoesumtessa examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence AT uludagkamil examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence AT versluismaarten examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence AT marquesjosep examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence |