Cargando…

Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence

These imaging data are examples of sub-millimeter resolution T(1)-weighted EPI (Echo Planar Imaging) acquired using the T(1)23DEPI (T(1)-imaging with 2 3D-EPIs) sequence [1]; functional MRI data with matching resolution and distortion, and MP2RAGE (Magnetization Prepared 2 Rapid Acquisition Gradient...

Descripción completa

Detalles Bibliográficos
Autores principales: van der Zwaag, Wietske, Buur, Pieter F., Fracasso, Alessio, van Doesum, Tessa, Uludağ, Kâmil, Versluis, Maarten, Marques, José P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6116420/
https://www.ncbi.nlm.nih.gov/pubmed/30175207
http://dx.doi.org/10.1016/j.dib.2018.08.030
_version_ 1783351602335186944
author van der Zwaag, Wietske
Buur, Pieter F.
Fracasso, Alessio
van Doesum, Tessa
Uludağ, Kâmil
Versluis, Maarten
Marques, José P.
author_facet van der Zwaag, Wietske
Buur, Pieter F.
Fracasso, Alessio
van Doesum, Tessa
Uludağ, Kâmil
Versluis, Maarten
Marques, José P.
author_sort van der Zwaag, Wietske
collection PubMed
description These imaging data are examples of sub-millimeter resolution T(1)-weighted EPI (Echo Planar Imaging) acquired using the T(1)23DEPI (T(1)-imaging with 2 3D-EPIs) sequence [1]; functional MRI data with matching resolution and distortion, and MP2RAGE (Magnetization Prepared 2 Rapid Acquisition Gradient Echoes) anatomical images [2], from the same subjects. Data from two protocols and subjects presented in the paper describing the sequence [1] are made available here: 1).. 0.8 mm protocol: whole brain, axial T(1)23DEPI T(1)-weighted images; a 5-minute fMRI run with the same orientation and 27 mm coverage in the slice selection direction, covering the primary visual cortex. fMRI data were acquired while the volunteer viewed a flashing checkerboard stimulus; the unsmoothed GLM results of the fMRI and a 0.64 mm resolution MP2RAGE from the same subject. These data are from Experiment 3 in [1]; 2).. 0.7 mm protocol: partial brain T(1)23DEPI T(1)-weighted images with longer or shorter readouts; matching coronal echo planar images again acquired while viewing a flashing checkerboard stimulus and a 0.64 mm whole brain MP2RAGE from the same subject. These data are from Experiment 1 in  [1].
format Online
Article
Text
id pubmed-6116420
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-61164202018-08-31 Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence van der Zwaag, Wietske Buur, Pieter F. Fracasso, Alessio van Doesum, Tessa Uludağ, Kâmil Versluis, Maarten Marques, José P. Data Brief Neuroscience These imaging data are examples of sub-millimeter resolution T(1)-weighted EPI (Echo Planar Imaging) acquired using the T(1)23DEPI (T(1)-imaging with 2 3D-EPIs) sequence [1]; functional MRI data with matching resolution and distortion, and MP2RAGE (Magnetization Prepared 2 Rapid Acquisition Gradient Echoes) anatomical images [2], from the same subjects. Data from two protocols and subjects presented in the paper describing the sequence [1] are made available here: 1).. 0.8 mm protocol: whole brain, axial T(1)23DEPI T(1)-weighted images; a 5-minute fMRI run with the same orientation and 27 mm coverage in the slice selection direction, covering the primary visual cortex. fMRI data were acquired while the volunteer viewed a flashing checkerboard stimulus; the unsmoothed GLM results of the fMRI and a 0.64 mm resolution MP2RAGE from the same subject. These data are from Experiment 3 in [1]; 2).. 0.7 mm protocol: partial brain T(1)23DEPI T(1)-weighted images with longer or shorter readouts; matching coronal echo planar images again acquired while viewing a flashing checkerboard stimulus and a 0.64 mm whole brain MP2RAGE from the same subject. These data are from Experiment 1 in  [1]. Elsevier 2018-08-16 /pmc/articles/PMC6116420/ /pubmed/30175207 http://dx.doi.org/10.1016/j.dib.2018.08.030 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Neuroscience
van der Zwaag, Wietske
Buur, Pieter F.
Fracasso, Alessio
van Doesum, Tessa
Uludağ, Kâmil
Versluis, Maarten
Marques, José P.
Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence
title Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence
title_full Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence
title_fullStr Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence
title_full_unstemmed Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence
title_short Examples of sub-millimeter, 7T, T(1)-weighted EPI datasets acquired with the T(1)23DEPI sequence
title_sort examples of sub-millimeter, 7t, t(1)-weighted epi datasets acquired with the t(1)23depi sequence
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6116420/
https://www.ncbi.nlm.nih.gov/pubmed/30175207
http://dx.doi.org/10.1016/j.dib.2018.08.030
work_keys_str_mv AT vanderzwaagwietske examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence
AT buurpieterf examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence
AT fracassoalessio examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence
AT vandoesumtessa examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence
AT uludagkamil examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence
AT versluismaarten examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence
AT marquesjosep examplesofsubmillimeter7tt1weightedepidatasetsacquiredwiththet123depisequence