Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants

A hip joint replacement is considered one of the most successful orthopedic surgical procedures although it involves challenges that must be overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer se...

Descripción completa

Detalles Bibliográficos
Autores principales: Affatato, Saverio, Merola, Massimiliano, Ruggiero, Alessandro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6117640/
https://www.ncbi.nlm.nih.gov/pubmed/30044409
http://dx.doi.org/10.3390/ma11081282
_version_ 1783351791514025984
author Affatato, Saverio
Merola, Massimiliano
Ruggiero, Alessandro
author_facet Affatato, Saverio
Merola, Massimiliano
Ruggiero, Alessandro
author_sort Affatato, Saverio
collection PubMed
description A hip joint replacement is considered one of the most successful orthopedic surgical procedures although it involves challenges that must be overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer service lifetime of the implant. The current replacement joint results are not fully satisfactory for these patients’ demands. As particle release is one of the main issues, pre-clinical experimental wear testing of total hip replacement components is an invaluable tool for evaluating new implant designs and materials. The aim of the study was to investigate the cup tensional state by varying the clearance between head and cup. For doing this we use a novel hard-on-soft finite element model with kinematic and dynamic conditions calculated from a musculoskeletal multibody model during the gait. Four different usual radial clearances were considered, ranging from 0 to 0.5 mm. The results showed that radial clearance plays a key role in acetabular cup stress-strain during the gait, showing from the 0 value to the highest, 0.5, a difference of 44% and 35% in terms of maximum pressure and deformation, respectively. Moreover, the presented model could be usefully exploited for complete elastohydrodynamic synovial lubrication modelling of the joint, with the aim of moving towards an increasingly realistic total hip arthroplasty in silico wear assessment accounting for differences in radial clearances.
format Online
Article
Text
id pubmed-6117640
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61176402018-09-05 Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants Affatato, Saverio Merola, Massimiliano Ruggiero, Alessandro Materials (Basel) Article A hip joint replacement is considered one of the most successful orthopedic surgical procedures although it involves challenges that must be overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer service lifetime of the implant. The current replacement joint results are not fully satisfactory for these patients’ demands. As particle release is one of the main issues, pre-clinical experimental wear testing of total hip replacement components is an invaluable tool for evaluating new implant designs and materials. The aim of the study was to investigate the cup tensional state by varying the clearance between head and cup. For doing this we use a novel hard-on-soft finite element model with kinematic and dynamic conditions calculated from a musculoskeletal multibody model during the gait. Four different usual radial clearances were considered, ranging from 0 to 0.5 mm. The results showed that radial clearance plays a key role in acetabular cup stress-strain during the gait, showing from the 0 value to the highest, 0.5, a difference of 44% and 35% in terms of maximum pressure and deformation, respectively. Moreover, the presented model could be usefully exploited for complete elastohydrodynamic synovial lubrication modelling of the joint, with the aim of moving towards an increasingly realistic total hip arthroplasty in silico wear assessment accounting for differences in radial clearances. MDPI 2018-07-25 /pmc/articles/PMC6117640/ /pubmed/30044409 http://dx.doi.org/10.3390/ma11081282 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Affatato, Saverio
Merola, Massimiliano
Ruggiero, Alessandro
Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants
title Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants
title_full Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants
title_fullStr Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants
title_full_unstemmed Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants
title_short Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants
title_sort development of a novel in silico model to investigate the influence of radial clearance on the acetabular cup contact pressure in hip implants
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6117640/
https://www.ncbi.nlm.nih.gov/pubmed/30044409
http://dx.doi.org/10.3390/ma11081282
work_keys_str_mv AT affatatosaverio developmentofanovelinsilicomodeltoinvestigatetheinfluenceofradialclearanceontheacetabularcupcontactpressureinhipimplants
AT merolamassimiliano developmentofanovelinsilicomodeltoinvestigatetheinfluenceofradialclearanceontheacetabularcupcontactpressureinhipimplants
AT ruggieroalessandro developmentofanovelinsilicomodeltoinvestigatetheinfluenceofradialclearanceontheacetabularcupcontactpressureinhipimplants