Cargando…

Adjustable photoacoustic tomography probe improves light delivery and image quality

One cause for suboptimal photoacoustic tomography (PAT) penetration depth is attenuation of incident light by soft tissue. To better understand this problem, we investigated the effects of illumination fiber optic bundle geometry on PAT penetration depth and signal-to-noise ratio. An adjustable, mot...

Descripción completa

Detalles Bibliográficos
Autores principales: Sangha, Gurneet S., Hale, Nicholas J., Goergen, Craig J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118042/
https://www.ncbi.nlm.nih.gov/pubmed/30175045
http://dx.doi.org/10.1016/j.pacs.2018.08.002
_version_ 1783351858604015616
author Sangha, Gurneet S.
Hale, Nicholas J.
Goergen, Craig J.
author_facet Sangha, Gurneet S.
Hale, Nicholas J.
Goergen, Craig J.
author_sort Sangha, Gurneet S.
collection PubMed
description One cause for suboptimal photoacoustic tomography (PAT) penetration depth is attenuation of incident light by soft tissue. To better understand this problem, we investigated the effects of illumination fiber optic bundle geometry on PAT penetration depth and signal-to-noise ratio. An adjustable, motorized PAT probe was used to reduce probe-skin reflection artifacts and improve light distribution in the image acquisition plane by tuning fiber orientation. We validated our motorized PAT probe through Monte Carlo simulations and ex vivo imaging of a tissue mimicking phantom, and in vivo imaging of murine periaortic fat. Overall, our ex vivo results showed a several millimeter improvement in penetration depth and in vivo results showed a >62% increase in lipid signal-to-noise ratio. Our PAT probe also utilized a 7-μm aluminum filter to block in vivo probe-skin reflection artifacts. Together, these findings showed the importance of optimizing illumination geometry to enhance PAT image quality.
format Online
Article
Text
id pubmed-6118042
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-61180422018-08-31 Adjustable photoacoustic tomography probe improves light delivery and image quality Sangha, Gurneet S. Hale, Nicholas J. Goergen, Craig J. Photoacoustics Research Article One cause for suboptimal photoacoustic tomography (PAT) penetration depth is attenuation of incident light by soft tissue. To better understand this problem, we investigated the effects of illumination fiber optic bundle geometry on PAT penetration depth and signal-to-noise ratio. An adjustable, motorized PAT probe was used to reduce probe-skin reflection artifacts and improve light distribution in the image acquisition plane by tuning fiber orientation. We validated our motorized PAT probe through Monte Carlo simulations and ex vivo imaging of a tissue mimicking phantom, and in vivo imaging of murine periaortic fat. Overall, our ex vivo results showed a several millimeter improvement in penetration depth and in vivo results showed a >62% increase in lipid signal-to-noise ratio. Our PAT probe also utilized a 7-μm aluminum filter to block in vivo probe-skin reflection artifacts. Together, these findings showed the importance of optimizing illumination geometry to enhance PAT image quality. Elsevier 2018-08-22 /pmc/articles/PMC6118042/ /pubmed/30175045 http://dx.doi.org/10.1016/j.pacs.2018.08.002 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Sangha, Gurneet S.
Hale, Nicholas J.
Goergen, Craig J.
Adjustable photoacoustic tomography probe improves light delivery and image quality
title Adjustable photoacoustic tomography probe improves light delivery and image quality
title_full Adjustable photoacoustic tomography probe improves light delivery and image quality
title_fullStr Adjustable photoacoustic tomography probe improves light delivery and image quality
title_full_unstemmed Adjustable photoacoustic tomography probe improves light delivery and image quality
title_short Adjustable photoacoustic tomography probe improves light delivery and image quality
title_sort adjustable photoacoustic tomography probe improves light delivery and image quality
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118042/
https://www.ncbi.nlm.nih.gov/pubmed/30175045
http://dx.doi.org/10.1016/j.pacs.2018.08.002
work_keys_str_mv AT sanghagurneets adjustablephotoacoustictomographyprobeimproveslightdeliveryandimagequality
AT halenicholasj adjustablephotoacoustictomographyprobeimproveslightdeliveryandimagequality
AT goergencraigj adjustablephotoacoustictomographyprobeimproveslightdeliveryandimagequality