Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis

BACKGROUND & OBJECTIVES: Legionella pneumophila, a ubiquitous aquatic organism is found to be associated with the development of the community as well as hospital-acquired pneumonia. Diagnosing Legionella infection is difficult unless supplemented with, diagnostic laboratory testing and establis...

Descripción completa

Detalles Bibliográficos
Autores principales: Jinna, Shihail, Gaikwad, Ujjwala Nitin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118141/
https://www.ncbi.nlm.nih.gov/pubmed/30168494
http://dx.doi.org/10.4103/ijmr.IJMR_527_17
_version_ 1783351870625939456
author Jinna, Shihail
Gaikwad, Ujjwala Nitin
author_facet Jinna, Shihail
Gaikwad, Ujjwala Nitin
author_sort Jinna, Shihail
collection PubMed
description BACKGROUND & OBJECTIVES: Legionella pneumophila, a ubiquitous aquatic organism is found to be associated with the development of the community as well as hospital-acquired pneumonia. Diagnosing Legionella infection is difficult unless supplemented with, diagnostic laboratory testing and established evidence for its presence in the hospital environment. Hence, the present study was undertaken to screen the hospital water supplies for the presence of L. pneumophila to show its presence in the hospital environment further facilitating early diagnosis and prevention of hospital-acquired legionellosis. METHODS: Water samples and swabs from the inner side of the same water taps were collected from 30 distal water outlets present in patient care areas of a tertiary care hospital. The filtrate obtained from water samples as well as swabs were inoculated directly and after acid buffer treatment on plain and selective (with polymyxin B, cycloheximide and vancomycin) buffered charcoal yeast extract medium. The colonies grown were identified using standard methods and confirmed for L. pneumophila by latex agglutination test. RESULTS: About 6.66 per cent (2/30) distal water outlets sampled were found to be contaminated with L. pneumophila serotype 2-15. Isolation was better with swabs compared to water samples. INTERPRETATION & CONCLUSIONS: The study showed the presence of L. pneumophila colonization of hospital water outlets at low levels. Periodic water sampling and active clinical surveillance in positive areas may be done to substantiate the evidence, to confirm or reject its role as a potential nosocomial pathogen in hospital environment.
format Online
Article
Text
id pubmed-6118141
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-61181412018-09-07 Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis Jinna, Shihail Gaikwad, Ujjwala Nitin Indian J Med Res Student IJMR BACKGROUND & OBJECTIVES: Legionella pneumophila, a ubiquitous aquatic organism is found to be associated with the development of the community as well as hospital-acquired pneumonia. Diagnosing Legionella infection is difficult unless supplemented with, diagnostic laboratory testing and established evidence for its presence in the hospital environment. Hence, the present study was undertaken to screen the hospital water supplies for the presence of L. pneumophila to show its presence in the hospital environment further facilitating early diagnosis and prevention of hospital-acquired legionellosis. METHODS: Water samples and swabs from the inner side of the same water taps were collected from 30 distal water outlets present in patient care areas of a tertiary care hospital. The filtrate obtained from water samples as well as swabs were inoculated directly and after acid buffer treatment on plain and selective (with polymyxin B, cycloheximide and vancomycin) buffered charcoal yeast extract medium. The colonies grown were identified using standard methods and confirmed for L. pneumophila by latex agglutination test. RESULTS: About 6.66 per cent (2/30) distal water outlets sampled were found to be contaminated with L. pneumophila serotype 2-15. Isolation was better with swabs compared to water samples. INTERPRETATION & CONCLUSIONS: The study showed the presence of L. pneumophila colonization of hospital water outlets at low levels. Periodic water sampling and active clinical surveillance in positive areas may be done to substantiate the evidence, to confirm or reject its role as a potential nosocomial pathogen in hospital environment. Medknow Publications & Media Pvt Ltd 2018-06 /pmc/articles/PMC6118141/ /pubmed/30168494 http://dx.doi.org/10.4103/ijmr.IJMR_527_17 Text en Copyright: © 2018 Indian Journal of Medical Research http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Student IJMR
Jinna, Shihail
Gaikwad, Ujjwala Nitin
Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis
title Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis
title_full Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis
title_fullStr Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis
title_full_unstemmed Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis
title_short Environmental surveillance of Legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis
title_sort environmental surveillance of legionella pneumophila in distal water supplies of a hospital for early identification & prevention of hospital-acquired legionellosis
topic Student IJMR
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118141/
https://www.ncbi.nlm.nih.gov/pubmed/30168494
http://dx.doi.org/10.4103/ijmr.IJMR_527_17
work_keys_str_mv AT jinnashihail environmentalsurveillanceoflegionellapneumophilaindistalwatersuppliesofahospitalforearlyidentificationpreventionofhospitalacquiredlegionellosis
AT gaikwadujjwalanitin environmentalsurveillanceoflegionellapneumophilaindistalwatersuppliesofahospitalforearlyidentificationpreventionofhospitalacquiredlegionellosis