Cargando…

Test-retest reliability of knee extensors endurance test with elastic resistance

BACKGROUND: Reliable clinical tests capable of measuring resistance are important tools for rehabilitation. One alternative that has recently increased in popularity is the use of elastic tubes, which stand out for being easy to handle, low cost, practical, and feasible. OBJECTIVE: Analyze the test-...

Descripción completa

Detalles Bibliográficos
Autores principales: Lopes, Jaqueline Santos Silva, Micheletti, Jéssica Kirsch, Machado, Aryane Flauzino, Souto, Larissa Rodrigues, de Lima, Heloísa Paes, Vanderlei, Franciele Marques, Junior, Jayme Netto, Pastre, Carlos Marcelo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118382/
https://www.ncbi.nlm.nih.gov/pubmed/30169527
http://dx.doi.org/10.1371/journal.pone.0203259
_version_ 1783351921214488576
author Lopes, Jaqueline Santos Silva
Micheletti, Jéssica Kirsch
Machado, Aryane Flauzino
Souto, Larissa Rodrigues
de Lima, Heloísa Paes
Vanderlei, Franciele Marques
Junior, Jayme Netto
Pastre, Carlos Marcelo
author_facet Lopes, Jaqueline Santos Silva
Micheletti, Jéssica Kirsch
Machado, Aryane Flauzino
Souto, Larissa Rodrigues
de Lima, Heloísa Paes
Vanderlei, Franciele Marques
Junior, Jayme Netto
Pastre, Carlos Marcelo
author_sort Lopes, Jaqueline Santos Silva
collection PubMed
description BACKGROUND: Reliable clinical tests capable of measuring resistance are important tools for rehabilitation. One alternative that has recently increased in popularity is the use of elastic tubes, which stand out for being easy to handle, low cost, practical, and feasible. OBJECTIVE: Analyze the test-retest reliability of the knee extensors muscle fatigue resistance test (FRT) with elastic tubes. METHODS: A total of 116 healthy young males, aged between 18 and 30 years old, participated in the study. Participants performed three pre-test stages: orientation, load presentation, and familiarization with equipment, lasting two weeks. Subsequently, they performed the FRT on two occasions (test and retest), with an interval of seven days. The reliability analyzes were performed using the intraclass correlation coefficient (ICC) with 95% confidence interval and typical measurement error (TME), also expressed as coefficient of variation (CV%). RESULTS: The findings regarding the reliability of the test demonstrated satisfactory values (time: ICC = 0.66; 95%CI [0.50; 0.76]; CV(%) = 9.34; repetition: ICC = 0.61; 95%CI [0.46; 0.73], CV(%) = 13.66; rhythm: ICC = 0.52; 95%CI [0.35; 0.67], CV(%) = 10.29. CONCLUSION: From the findings presented, it is concluded that the proposed clinical test with elastic tubes demonstrates evidence of acceptable values.
format Online
Article
Text
id pubmed-6118382
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61183822018-09-16 Test-retest reliability of knee extensors endurance test with elastic resistance Lopes, Jaqueline Santos Silva Micheletti, Jéssica Kirsch Machado, Aryane Flauzino Souto, Larissa Rodrigues de Lima, Heloísa Paes Vanderlei, Franciele Marques Junior, Jayme Netto Pastre, Carlos Marcelo PLoS One Research Article BACKGROUND: Reliable clinical tests capable of measuring resistance are important tools for rehabilitation. One alternative that has recently increased in popularity is the use of elastic tubes, which stand out for being easy to handle, low cost, practical, and feasible. OBJECTIVE: Analyze the test-retest reliability of the knee extensors muscle fatigue resistance test (FRT) with elastic tubes. METHODS: A total of 116 healthy young males, aged between 18 and 30 years old, participated in the study. Participants performed three pre-test stages: orientation, load presentation, and familiarization with equipment, lasting two weeks. Subsequently, they performed the FRT on two occasions (test and retest), with an interval of seven days. The reliability analyzes were performed using the intraclass correlation coefficient (ICC) with 95% confidence interval and typical measurement error (TME), also expressed as coefficient of variation (CV%). RESULTS: The findings regarding the reliability of the test demonstrated satisfactory values (time: ICC = 0.66; 95%CI [0.50; 0.76]; CV(%) = 9.34; repetition: ICC = 0.61; 95%CI [0.46; 0.73], CV(%) = 13.66; rhythm: ICC = 0.52; 95%CI [0.35; 0.67], CV(%) = 10.29. CONCLUSION: From the findings presented, it is concluded that the proposed clinical test with elastic tubes demonstrates evidence of acceptable values. Public Library of Science 2018-08-31 /pmc/articles/PMC6118382/ /pubmed/30169527 http://dx.doi.org/10.1371/journal.pone.0203259 Text en © 2018 Lopes et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Lopes, Jaqueline Santos Silva
Micheletti, Jéssica Kirsch
Machado, Aryane Flauzino
Souto, Larissa Rodrigues
de Lima, Heloísa Paes
Vanderlei, Franciele Marques
Junior, Jayme Netto
Pastre, Carlos Marcelo
Test-retest reliability of knee extensors endurance test with elastic resistance
title Test-retest reliability of knee extensors endurance test with elastic resistance
title_full Test-retest reliability of knee extensors endurance test with elastic resistance
title_fullStr Test-retest reliability of knee extensors endurance test with elastic resistance
title_full_unstemmed Test-retest reliability of knee extensors endurance test with elastic resistance
title_short Test-retest reliability of knee extensors endurance test with elastic resistance
title_sort test-retest reliability of knee extensors endurance test with elastic resistance
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118382/
https://www.ncbi.nlm.nih.gov/pubmed/30169527
http://dx.doi.org/10.1371/journal.pone.0203259
work_keys_str_mv AT lopesjaquelinesantossilva testretestreliabilityofkneeextensorsendurancetestwithelasticresistance
AT michelettijessicakirsch testretestreliabilityofkneeextensorsendurancetestwithelasticresistance
AT machadoaryaneflauzino testretestreliabilityofkneeextensorsendurancetestwithelasticresistance
AT soutolarissarodrigues testretestreliabilityofkneeextensorsendurancetestwithelasticresistance
AT delimaheloisapaes testretestreliabilityofkneeextensorsendurancetestwithelasticresistance
AT vanderleifrancielemarques testretestreliabilityofkneeextensorsendurancetestwithelasticresistance
AT juniorjaymenetto testretestreliabilityofkneeextensorsendurancetestwithelasticresistance
AT pastrecarlosmarcelo testretestreliabilityofkneeextensorsendurancetestwithelasticresistance