Cargando…
Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation
PURPOSE: This observational study investigates the influence of interfractional motion on clinical target volume (CTV) coverage, planning target volume (PTV) margins, and rectum tissue sparing in carbon ion radiation therapy (CIRT). It reports dose coverage to target structures and organs at risk in...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118389/ https://www.ncbi.nlm.nih.gov/pubmed/30169520 http://dx.doi.org/10.1371/journal.pone.0203289 |
_version_ | 1783351922886967296 |
---|---|
author | Bridges, Daniel Kawamura, Hidemasa Kanai, Tatsuaki |
author_facet | Bridges, Daniel Kawamura, Hidemasa Kanai, Tatsuaki |
author_sort | Bridges, Daniel |
collection | PubMed |
description | PURPOSE: This observational study investigates the influence of interfractional motion on clinical target volume (CTV) coverage, planning target volume (PTV) margins, and rectum tissue sparing in carbon ion radiation therapy (CIRT). It reports dose coverage to target structures and organs at risk in the presence of interfractional motion, investigates rectal tissue sparing, and provides recommendations for lowering the rate of toxicity. We also propose probabilistic DVH based on cone-beam computed tomography (CBCT) table shifts from photon therapy for consideration in bone-matching CIRT treatment planning to represent probable dose to our CIRT patient population. METHODS: At Gunma University Hospital intensity-modulated x-ray therapy (IMXT, aka IMRT) prostate cancer patients are positioned on a table which is shifted twice based on CBCT to align bones and then align prostate tissue to isocenter. These shifts thereby contain interfractional motion. A total of 1306 such table shifts from 85 patients were collected. Normal probability distributions were fit to the difference between bone-matching and prostate-matching CBCT-to-planning CT table shifts (i.e. interfractional motion). Between 2011 and 2016 CIRT prostate patients were treated with three beams to PTV1 (lateral-opposing and anterior) one per day for 9 fractions and two beams for a boost PTV2 (lateral-opposing) one per day for 7 fractions for a prescribed total of 57.6 Gy(RBE) as follows: PTV1 extends the prostate contour by 10/10, 5/10, 6/6 mm in the right/left, posterior/anterior, and superior/inferior directions, respectively, and the proximal seminal vesicles contour by 5 mm superiorly and inferiorly, 3 mm right and left. PTV2 reduces PTV1 posteriorly along a straight line to exclude the rectum and reduces the superior and inferior margins by 6 mm. Probable interfractional motion for 40 patients was simulated using each patient’s own beam data as follows: The previously fit normal probability distributions were randomly sampled 2000 times per patient, and the five beams were shifted and summed with the same relative weighting as in the 16-fraction regimen. The resulting dose distribution was then scaled back down by 16/2000 to match the prescribed number of fractions. We then analyzed the resulting doses to contoured structures. RESULTS: Probable dose to rectum is substantially less than planned: For example, mean+-standard deviation D2% for planned and probable DVH is 51+-1.9 and 45+-2.4, respectively. Cumulative DVH show mean CTV fraction receiving a given probable dose is less than the mean fraction receiving the corresponding planned dose for doses larger than 52 Gy(RBE), up to 19% less at 57.4 Gy(RBE). Our PTV1 margins generally cover 95% of interfractional motion but seminal vesicles and inferior prostate receive less dose than planned due to insufficient PTV2 margins. CONCLUSION: Assuming rigidly shifting interfractional motion around the prostate region and neglecting minor changes in soft tissue stopping power, interfractional motion resulted in target underdosing but better tissue sparing in all cases. Given our low rates of relapse and recurrence, it appears less curative dose is needed than previously thought or else current planning target margins may be excessive: Planning target volumes should be reconsidered with the adoption of dose verification methods. Our probable dose distributions quantify expected dose for future dose verification studies. |
format | Online Article Text |
id | pubmed-6118389 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-61183892018-09-16 Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation Bridges, Daniel Kawamura, Hidemasa Kanai, Tatsuaki PLoS One Research Article PURPOSE: This observational study investigates the influence of interfractional motion on clinical target volume (CTV) coverage, planning target volume (PTV) margins, and rectum tissue sparing in carbon ion radiation therapy (CIRT). It reports dose coverage to target structures and organs at risk in the presence of interfractional motion, investigates rectal tissue sparing, and provides recommendations for lowering the rate of toxicity. We also propose probabilistic DVH based on cone-beam computed tomography (CBCT) table shifts from photon therapy for consideration in bone-matching CIRT treatment planning to represent probable dose to our CIRT patient population. METHODS: At Gunma University Hospital intensity-modulated x-ray therapy (IMXT, aka IMRT) prostate cancer patients are positioned on a table which is shifted twice based on CBCT to align bones and then align prostate tissue to isocenter. These shifts thereby contain interfractional motion. A total of 1306 such table shifts from 85 patients were collected. Normal probability distributions were fit to the difference between bone-matching and prostate-matching CBCT-to-planning CT table shifts (i.e. interfractional motion). Between 2011 and 2016 CIRT prostate patients were treated with three beams to PTV1 (lateral-opposing and anterior) one per day for 9 fractions and two beams for a boost PTV2 (lateral-opposing) one per day for 7 fractions for a prescribed total of 57.6 Gy(RBE) as follows: PTV1 extends the prostate contour by 10/10, 5/10, 6/6 mm in the right/left, posterior/anterior, and superior/inferior directions, respectively, and the proximal seminal vesicles contour by 5 mm superiorly and inferiorly, 3 mm right and left. PTV2 reduces PTV1 posteriorly along a straight line to exclude the rectum and reduces the superior and inferior margins by 6 mm. Probable interfractional motion for 40 patients was simulated using each patient’s own beam data as follows: The previously fit normal probability distributions were randomly sampled 2000 times per patient, and the five beams were shifted and summed with the same relative weighting as in the 16-fraction regimen. The resulting dose distribution was then scaled back down by 16/2000 to match the prescribed number of fractions. We then analyzed the resulting doses to contoured structures. RESULTS: Probable dose to rectum is substantially less than planned: For example, mean+-standard deviation D2% for planned and probable DVH is 51+-1.9 and 45+-2.4, respectively. Cumulative DVH show mean CTV fraction receiving a given probable dose is less than the mean fraction receiving the corresponding planned dose for doses larger than 52 Gy(RBE), up to 19% less at 57.4 Gy(RBE). Our PTV1 margins generally cover 95% of interfractional motion but seminal vesicles and inferior prostate receive less dose than planned due to insufficient PTV2 margins. CONCLUSION: Assuming rigidly shifting interfractional motion around the prostate region and neglecting minor changes in soft tissue stopping power, interfractional motion resulted in target underdosing but better tissue sparing in all cases. Given our low rates of relapse and recurrence, it appears less curative dose is needed than previously thought or else current planning target margins may be excessive: Planning target volumes should be reconsidered with the adoption of dose verification methods. Our probable dose distributions quantify expected dose for future dose verification studies. Public Library of Science 2018-08-31 /pmc/articles/PMC6118389/ /pubmed/30169520 http://dx.doi.org/10.1371/journal.pone.0203289 Text en © 2018 Bridges et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Bridges, Daniel Kawamura, Hidemasa Kanai, Tatsuaki Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation |
title | Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation |
title_full | Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation |
title_fullStr | Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation |
title_full_unstemmed | Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation |
title_short | Probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation |
title_sort | probabilistic dose distribution from interfractional motion in carbon ion radiation therapy for prostate cancer shows rectum sparing with moderate target coverage degradation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118389/ https://www.ncbi.nlm.nih.gov/pubmed/30169520 http://dx.doi.org/10.1371/journal.pone.0203289 |
work_keys_str_mv | AT bridgesdaniel probabilisticdosedistributionfrominterfractionalmotionincarbonionradiationtherapyforprostatecancershowsrectumsparingwithmoderatetargetcoveragedegradation AT kawamurahidemasa probabilisticdosedistributionfrominterfractionalmotionincarbonionradiationtherapyforprostatecancershowsrectumsparingwithmoderatetargetcoveragedegradation AT kanaitatsuaki probabilisticdosedistributionfrominterfractionalmotionincarbonionradiationtherapyforprostatecancershowsrectumsparingwithmoderatetargetcoveragedegradation |