Cargando…

A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study

BACKGROUND: In infants, securing the airway is time-critical because of anatomical and physiological differences related to airway management in children less than 1 year old. The aim of this study was to compare the time to ventilation using two different hyperangulated video laryngoscope blades wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Kriege, Marc, Pirlich, Nina, Ott, Thomas, Wittenmeier, Eva, Dette, Frank
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119241/
https://www.ncbi.nlm.nih.gov/pubmed/30170540
http://dx.doi.org/10.1186/s12871-018-0580-y
_version_ 1783352048759078912
author Kriege, Marc
Pirlich, Nina
Ott, Thomas
Wittenmeier, Eva
Dette, Frank
author_facet Kriege, Marc
Pirlich, Nina
Ott, Thomas
Wittenmeier, Eva
Dette, Frank
author_sort Kriege, Marc
collection PubMed
description BACKGROUND: In infants, securing the airway is time-critical because of anatomical and physiological differences related to airway management in children less than 1 year old. The aim of this study was to compare the time to ventilation using two different hyperangulated video laryngoscope blades with the time to ventilation via conventional direct laryngoscopy in a normal airway [NA] and in a simulated difficult airway [DA]. METHODS: This study was a comparative, bicentric, open-label, randomized controlled evaluation. An infant high-fidelity simulator (SimBaby™; Laerdal® Medical, Stavanger, Norway) was used, and two scenarios were proposed, as follows: NA and DA evoked with tongue edema and cervical collar. After theoretical and practical briefing, each participant compared in the two airway scenarios the novel King Vision™ Pediatric aBlade (KV) (Ambu® A/S, Bad Nauheim, Germany) video laryngoscope and the C-MAC™ D-blade Ped (DB) (Karl Storz® SE & Co. KG, Tuttlingen, Germany) video laryngoscope to conventional laryngoscopy using the Miller Blade (MiB) and the Macintosh Blade (MaB) in a random sequence. RESULTS: Eighty physicians (65 AN and 15 PCCM staff) were included. In the NA scenario, the median [IQR] time to successful time to ventilation (TTV) was significantly shorter for the KV at 13 s [12–15 s] than for the MaB at 14.5 s [13–16 s], DB at 14.5 s [13–16] and MiB at 16 s [14–19] (p < 0.001). In DA, the KV also shortened TTV to 14 s [13–16], whereas TTV was 23 s with the MaB [20–26], 19 s with the DB [16–21], and 27 s with the MiB [22–31] (p < 0.001). There were no differences in first-pass intubation success rates (FPAs) between hyperangulated blades and direct laryngoscopes in NA. In DA, the hyperangulated blades enabled 92 (DB) to 100% (KV) FPAs compared with 65 (MiB) to 76% (MaB) for conventional laryngoscopy (p < 0.001). CONCLUSION: Video laryngoscopes with hyperangulated blades were associated with shorter TTV in normal and difficult infant airway situations. The higher FPAs of hyperangulated blades in DA may avoid desaturations and decrease adverse events in pediatric airway management. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12871-018-0580-y) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6119241
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-61192412018-09-05 A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study Kriege, Marc Pirlich, Nina Ott, Thomas Wittenmeier, Eva Dette, Frank BMC Anesthesiol Research Article BACKGROUND: In infants, securing the airway is time-critical because of anatomical and physiological differences related to airway management in children less than 1 year old. The aim of this study was to compare the time to ventilation using two different hyperangulated video laryngoscope blades with the time to ventilation via conventional direct laryngoscopy in a normal airway [NA] and in a simulated difficult airway [DA]. METHODS: This study was a comparative, bicentric, open-label, randomized controlled evaluation. An infant high-fidelity simulator (SimBaby™; Laerdal® Medical, Stavanger, Norway) was used, and two scenarios were proposed, as follows: NA and DA evoked with tongue edema and cervical collar. After theoretical and practical briefing, each participant compared in the two airway scenarios the novel King Vision™ Pediatric aBlade (KV) (Ambu® A/S, Bad Nauheim, Germany) video laryngoscope and the C-MAC™ D-blade Ped (DB) (Karl Storz® SE & Co. KG, Tuttlingen, Germany) video laryngoscope to conventional laryngoscopy using the Miller Blade (MiB) and the Macintosh Blade (MaB) in a random sequence. RESULTS: Eighty physicians (65 AN and 15 PCCM staff) were included. In the NA scenario, the median [IQR] time to successful time to ventilation (TTV) was significantly shorter for the KV at 13 s [12–15 s] than for the MaB at 14.5 s [13–16 s], DB at 14.5 s [13–16] and MiB at 16 s [14–19] (p < 0.001). In DA, the KV also shortened TTV to 14 s [13–16], whereas TTV was 23 s with the MaB [20–26], 19 s with the DB [16–21], and 27 s with the MiB [22–31] (p < 0.001). There were no differences in first-pass intubation success rates (FPAs) between hyperangulated blades and direct laryngoscopes in NA. In DA, the hyperangulated blades enabled 92 (DB) to 100% (KV) FPAs compared with 65 (MiB) to 76% (MaB) for conventional laryngoscopy (p < 0.001). CONCLUSION: Video laryngoscopes with hyperangulated blades were associated with shorter TTV in normal and difficult infant airway situations. The higher FPAs of hyperangulated blades in DA may avoid desaturations and decrease adverse events in pediatric airway management. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12871-018-0580-y) contains supplementary material, which is available to authorized users. BioMed Central 2018-08-31 /pmc/articles/PMC6119241/ /pubmed/30170540 http://dx.doi.org/10.1186/s12871-018-0580-y Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Kriege, Marc
Pirlich, Nina
Ott, Thomas
Wittenmeier, Eva
Dette, Frank
A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study
title A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study
title_full A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study
title_fullStr A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study
title_full_unstemmed A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study
title_short A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study
title_sort comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119241/
https://www.ncbi.nlm.nih.gov/pubmed/30170540
http://dx.doi.org/10.1186/s12871-018-0580-y
work_keys_str_mv AT kriegemarc acomparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT pirlichnina acomparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT ottthomas acomparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT wittenmeiereva acomparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT dettefrank acomparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT kriegemarc comparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT pirlichnina comparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT ottthomas comparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT wittenmeiereva comparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy
AT dettefrank comparisonoftwohyperangulatedvideolaryngoscopebladestodirectlaryngoscopyinasimulatedinfantairwayabicentriccomparativerandomizedmanikinstudy