Cargando…
Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis
Membrane–electrode assemblies (MEAs) designed for a polymer electrolyte membrane (PEM) water electrolyser based on a short-side chain (SSC) perfluorosulfonic acid (PFSA) membrane, Aquivion(®), and an advanced Ir-Ru oxide anode electro-catalyst, with various cathode and anode noble metal loadings, we...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119855/ https://www.ncbi.nlm.nih.gov/pubmed/30087229 http://dx.doi.org/10.3390/ma11081368 |
_version_ | 1783352147446857728 |
---|---|
author | Siracusano, Stefania Trocino, Stefano Briguglio, Nicola Baglio, Vincenzo Aricò, Antonino S. |
author_facet | Siracusano, Stefania Trocino, Stefano Briguglio, Nicola Baglio, Vincenzo Aricò, Antonino S. |
author_sort | Siracusano, Stefania |
collection | PubMed |
description | Membrane–electrode assemblies (MEAs) designed for a polymer electrolyte membrane (PEM) water electrolyser based on a short-side chain (SSC) perfluorosulfonic acid (PFSA) membrane, Aquivion(®), and an advanced Ir-Ru oxide anode electro-catalyst, with various cathode and anode noble metal loadings, were investigated. Electrochemical impedance spectroscopy (EIS), in combination with performance and durability tests, provided useful information to identify rate-determining steps and to quantify the impact of the different phenomena on the electrolysis efficiency and stability characteristics as a function of the MEA properties. This technique appears to be a useful diagnostic tool to individuate different phenomena and to quantify their effect on the performance and degradation of PEM electrolysis cells. |
format | Online Article Text |
id | pubmed-6119855 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61198552018-09-05 Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis Siracusano, Stefania Trocino, Stefano Briguglio, Nicola Baglio, Vincenzo Aricò, Antonino S. Materials (Basel) Article Membrane–electrode assemblies (MEAs) designed for a polymer electrolyte membrane (PEM) water electrolyser based on a short-side chain (SSC) perfluorosulfonic acid (PFSA) membrane, Aquivion(®), and an advanced Ir-Ru oxide anode electro-catalyst, with various cathode and anode noble metal loadings, were investigated. Electrochemical impedance spectroscopy (EIS), in combination with performance and durability tests, provided useful information to identify rate-determining steps and to quantify the impact of the different phenomena on the electrolysis efficiency and stability characteristics as a function of the MEA properties. This technique appears to be a useful diagnostic tool to individuate different phenomena and to quantify their effect on the performance and degradation of PEM electrolysis cells. MDPI 2018-08-07 /pmc/articles/PMC6119855/ /pubmed/30087229 http://dx.doi.org/10.3390/ma11081368 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Siracusano, Stefania Trocino, Stefano Briguglio, Nicola Baglio, Vincenzo Aricò, Antonino S. Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis |
title | Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis |
title_full | Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis |
title_fullStr | Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis |
title_full_unstemmed | Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis |
title_short | Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis |
title_sort | electrochemical impedance spectroscopy as a diagnostic tool in polymer electrolyte membrane electrolysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119855/ https://www.ncbi.nlm.nih.gov/pubmed/30087229 http://dx.doi.org/10.3390/ma11081368 |
work_keys_str_mv | AT siracusanostefania electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis AT trocinostefano electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis AT briguglionicola electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis AT bagliovincenzo electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis AT aricoantoninos electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis |