Cargando…

Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis

Membrane–electrode assemblies (MEAs) designed for a polymer electrolyte membrane (PEM) water electrolyser based on a short-side chain (SSC) perfluorosulfonic acid (PFSA) membrane, Aquivion(®), and an advanced Ir-Ru oxide anode electro-catalyst, with various cathode and anode noble metal loadings, we...

Descripción completa

Detalles Bibliográficos
Autores principales: Siracusano, Stefania, Trocino, Stefano, Briguglio, Nicola, Baglio, Vincenzo, Aricò, Antonino S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119855/
https://www.ncbi.nlm.nih.gov/pubmed/30087229
http://dx.doi.org/10.3390/ma11081368
_version_ 1783352147446857728
author Siracusano, Stefania
Trocino, Stefano
Briguglio, Nicola
Baglio, Vincenzo
Aricò, Antonino S.
author_facet Siracusano, Stefania
Trocino, Stefano
Briguglio, Nicola
Baglio, Vincenzo
Aricò, Antonino S.
author_sort Siracusano, Stefania
collection PubMed
description Membrane–electrode assemblies (MEAs) designed for a polymer electrolyte membrane (PEM) water electrolyser based on a short-side chain (SSC) perfluorosulfonic acid (PFSA) membrane, Aquivion(®), and an advanced Ir-Ru oxide anode electro-catalyst, with various cathode and anode noble metal loadings, were investigated. Electrochemical impedance spectroscopy (EIS), in combination with performance and durability tests, provided useful information to identify rate-determining steps and to quantify the impact of the different phenomena on the electrolysis efficiency and stability characteristics as a function of the MEA properties. This technique appears to be a useful diagnostic tool to individuate different phenomena and to quantify their effect on the performance and degradation of PEM electrolysis cells.
format Online
Article
Text
id pubmed-6119855
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61198552018-09-05 Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis Siracusano, Stefania Trocino, Stefano Briguglio, Nicola Baglio, Vincenzo Aricò, Antonino S. Materials (Basel) Article Membrane–electrode assemblies (MEAs) designed for a polymer electrolyte membrane (PEM) water electrolyser based on a short-side chain (SSC) perfluorosulfonic acid (PFSA) membrane, Aquivion(®), and an advanced Ir-Ru oxide anode electro-catalyst, with various cathode and anode noble metal loadings, were investigated. Electrochemical impedance spectroscopy (EIS), in combination with performance and durability tests, provided useful information to identify rate-determining steps and to quantify the impact of the different phenomena on the electrolysis efficiency and stability characteristics as a function of the MEA properties. This technique appears to be a useful diagnostic tool to individuate different phenomena and to quantify their effect on the performance and degradation of PEM electrolysis cells. MDPI 2018-08-07 /pmc/articles/PMC6119855/ /pubmed/30087229 http://dx.doi.org/10.3390/ma11081368 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Siracusano, Stefania
Trocino, Stefano
Briguglio, Nicola
Baglio, Vincenzo
Aricò, Antonino S.
Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis
title Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis
title_full Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis
title_fullStr Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis
title_full_unstemmed Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis
title_short Electrochemical Impedance Spectroscopy as a Diagnostic Tool in Polymer Electrolyte Membrane Electrolysis
title_sort electrochemical impedance spectroscopy as a diagnostic tool in polymer electrolyte membrane electrolysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119855/
https://www.ncbi.nlm.nih.gov/pubmed/30087229
http://dx.doi.org/10.3390/ma11081368
work_keys_str_mv AT siracusanostefania electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis
AT trocinostefano electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis
AT briguglionicola electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis
AT bagliovincenzo electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis
AT aricoantoninos electrochemicalimpedancespectroscopyasadiagnostictoolinpolymerelectrolytemembraneelectrolysis