Design of a Scaffold Parameter Selection System with Additive Manufacturing for a Biomedical Cell Culture
Open-source 3D printers mean objects can be quickly and efficiently produced. However, design and fabrication parameters need to be optimized to set up the correct printing procedure; a procedure in which the characteristics of the printing materials selected for use can also influence the process....
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119890/ https://www.ncbi.nlm.nih.gov/pubmed/30110889 http://dx.doi.org/10.3390/ma11081427 |
_version_ | 1783352155521941504 |
---|---|
author | Rabionet, Marc Polonio, Emma Guerra, Antonio J. Martin, Jessica Puig, Teresa Ciurana, Joaquim |
author_facet | Rabionet, Marc Polonio, Emma Guerra, Antonio J. Martin, Jessica Puig, Teresa Ciurana, Joaquim |
author_sort | Rabionet, Marc |
collection | PubMed |
description | Open-source 3D printers mean objects can be quickly and efficiently produced. However, design and fabrication parameters need to be optimized to set up the correct printing procedure; a procedure in which the characteristics of the printing materials selected for use can also influence the process. This work focuses on optimizing the printing process of the open-source 3D extruder machine RepRap, which is used to manufacture poly(ε-caprolactone) (PCL) scaffolds for cell culture applications. PCL is a biocompatible polymer that is free of toxic dye and has been used to fabricate scaffolds, i.e., solid structures suitable for 3D cancer cell cultures. Scaffold cell culture has been described as enhancing cancer stem cell (CSC) populations related to tumor chemoresistance and/or their recurrence after chemotherapy. A RepRap BCN3D+ printer and 3 mm PCL wire were used to fabricate circular scaffolds. Design and fabrication parameters were first determined with SolidWorks and Slic3r software and subsequently optimized following a novel sequential flowchart. In the flowchart described here, the parameters were gradually optimized step by step, by taking several measurable variables of the resulting scaffolds into consideration to guarantee high-quality printing. Three deposition angles (45°, 60° and 90°) were fabricated and tested. MCF-7 breast carcinoma cells and NIH/3T3 murine fibroblasts were used to assess scaffold adequacy for 3D cell cultures. The 60° scaffolds were found to be suitable for the purpose. Therefore, PCL scaffolds fabricated via the flowchart optimization with a RepRap 3D printer could be used for 3D cell cultures and may boost CSCs to study new therapeutic treatments for this malignant population. Moreover, the flowchart defined here could represent a standard procedure for non-engineers (i.e., mainly physicians) when manufacturing new culture systems is required. |
format | Online Article Text |
id | pubmed-6119890 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61198902018-09-05 Design of a Scaffold Parameter Selection System with Additive Manufacturing for a Biomedical Cell Culture Rabionet, Marc Polonio, Emma Guerra, Antonio J. Martin, Jessica Puig, Teresa Ciurana, Joaquim Materials (Basel) Article Open-source 3D printers mean objects can be quickly and efficiently produced. However, design and fabrication parameters need to be optimized to set up the correct printing procedure; a procedure in which the characteristics of the printing materials selected for use can also influence the process. This work focuses on optimizing the printing process of the open-source 3D extruder machine RepRap, which is used to manufacture poly(ε-caprolactone) (PCL) scaffolds for cell culture applications. PCL is a biocompatible polymer that is free of toxic dye and has been used to fabricate scaffolds, i.e., solid structures suitable for 3D cancer cell cultures. Scaffold cell culture has been described as enhancing cancer stem cell (CSC) populations related to tumor chemoresistance and/or their recurrence after chemotherapy. A RepRap BCN3D+ printer and 3 mm PCL wire were used to fabricate circular scaffolds. Design and fabrication parameters were first determined with SolidWorks and Slic3r software and subsequently optimized following a novel sequential flowchart. In the flowchart described here, the parameters were gradually optimized step by step, by taking several measurable variables of the resulting scaffolds into consideration to guarantee high-quality printing. Three deposition angles (45°, 60° and 90°) were fabricated and tested. MCF-7 breast carcinoma cells and NIH/3T3 murine fibroblasts were used to assess scaffold adequacy for 3D cell cultures. The 60° scaffolds were found to be suitable for the purpose. Therefore, PCL scaffolds fabricated via the flowchart optimization with a RepRap 3D printer could be used for 3D cell cultures and may boost CSCs to study new therapeutic treatments for this malignant population. Moreover, the flowchart defined here could represent a standard procedure for non-engineers (i.e., mainly physicians) when manufacturing new culture systems is required. MDPI 2018-08-14 /pmc/articles/PMC6119890/ /pubmed/30110889 http://dx.doi.org/10.3390/ma11081427 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rabionet, Marc Polonio, Emma Guerra, Antonio J. Martin, Jessica Puig, Teresa Ciurana, Joaquim Design of a Scaffold Parameter Selection System with Additive Manufacturing for a Biomedical Cell Culture |
title | Design of a Scaffold Parameter Selection System with Additive Manufacturing for a Biomedical Cell Culture |
title_full | Design of a Scaffold Parameter Selection System with Additive Manufacturing for a Biomedical Cell Culture |
title_fullStr | Design of a Scaffold Parameter Selection System with Additive Manufacturing for a Biomedical Cell Culture |
title_full_unstemmed | Design of a Scaffold Parameter Selection System with Additive Manufacturing for a Biomedical Cell Culture |
title_short | Design of a Scaffold Parameter Selection System with Additive Manufacturing for a Biomedical Cell Culture |
title_sort | design of a scaffold parameter selection system with additive manufacturing for a biomedical cell culture |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119890/ https://www.ncbi.nlm.nih.gov/pubmed/30110889 http://dx.doi.org/10.3390/ma11081427 |
work_keys_str_mv | AT rabionetmarc designofascaffoldparameterselectionsystemwithadditivemanufacturingforabiomedicalcellculture AT polonioemma designofascaffoldparameterselectionsystemwithadditivemanufacturingforabiomedicalcellculture AT guerraantonioj designofascaffoldparameterselectionsystemwithadditivemanufacturingforabiomedicalcellculture AT martinjessica designofascaffoldparameterselectionsystemwithadditivemanufacturingforabiomedicalcellculture AT puigteresa designofascaffoldparameterselectionsystemwithadditivemanufacturingforabiomedicalcellculture AT ciuranajoaquim designofascaffoldparameterselectionsystemwithadditivemanufacturingforabiomedicalcellculture |