Development of a highly sensitive and reliable enzyme-linked immunosorbent assay for MUC5AC in human tears extracted from Schirmer strips

PURPOSE: Reliable measurement of MUC5AC in human tears is essential for elucidation of the pathophysiological role of MUC5AC in dry eye disease. The purpose of this study was to develop a sensitive and reliable method for measurement of MUC5AC in human tear samples extracted from Schirmer strips by...

Descripción completa

Detalles Bibliográficos
Autores principales: Miyake, Hideki, Mori, Naoto, Mano, Hidetoshi, Imanaka, Takahiro, Nakamura, Masatsugu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6120569/
https://www.ncbi.nlm.nih.gov/pubmed/30214141
http://dx.doi.org/10.2147/OPTH.S170552
_version_ 1783352299673878528
author Miyake, Hideki
Mori, Naoto
Mano, Hidetoshi
Imanaka, Takahiro
Nakamura, Masatsugu
author_facet Miyake, Hideki
Mori, Naoto
Mano, Hidetoshi
Imanaka, Takahiro
Nakamura, Masatsugu
author_sort Miyake, Hideki
collection PubMed
description PURPOSE: Reliable measurement of MUC5AC in human tears is essential for elucidation of the pathophysiological role of MUC5AC in dry eye disease. The purpose of this study was to develop a sensitive and reliable method for measurement of MUC5AC in human tear samples extracted from Schirmer strips by modifying a commercially available ELISA. METHODS: MUC5AC was extracted from Schirmer strips containing human tears by PBS with various concentrations of polysorbate 20. The extracts were treated with neuraminidase A to cleave the sialic acids in MUC5AC. An ELISA plate was blocked to prevent nonspecific binding. The rate of extraction of MUC5AC from Schirmer strips, linearity of dilution, limit of quantification, calibration range, and intra-assay and inter-assay reproducibility were examined. RESULTS: MUC5AC was extracted using polysorbate 20 in a concentration-dependent manner. Extraction was more efficient at 37°C than at 25°C. The signal-to-noise ratio of the assay was dramatically increased by treatment with neuraminidase A. Treatment with a blocking reagent before incubation produced good linearity of dilution. The inter-assay and intra-assay coefficients of variation were ≤16.6%. The relative error was within 13%. CONCLUSION: We developed an efficient method for extraction of MUC5AC from Schirmer strips and a highly sensitive, reliable assay for MUC5AC in human tear samples using a commercially available ELISA kit. This method will aid in our understanding of the pathophysiology of dry eye, assessment of the effects of treatment in daily practice, and selection of appropriate therapeutic agents for patients.
format Online
Article
Text
id pubmed-6120569
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-61205692018-09-13 Development of a highly sensitive and reliable enzyme-linked immunosorbent assay for MUC5AC in human tears extracted from Schirmer strips Miyake, Hideki Mori, Naoto Mano, Hidetoshi Imanaka, Takahiro Nakamura, Masatsugu Clin Ophthalmol Original Research PURPOSE: Reliable measurement of MUC5AC in human tears is essential for elucidation of the pathophysiological role of MUC5AC in dry eye disease. The purpose of this study was to develop a sensitive and reliable method for measurement of MUC5AC in human tear samples extracted from Schirmer strips by modifying a commercially available ELISA. METHODS: MUC5AC was extracted from Schirmer strips containing human tears by PBS with various concentrations of polysorbate 20. The extracts were treated with neuraminidase A to cleave the sialic acids in MUC5AC. An ELISA plate was blocked to prevent nonspecific binding. The rate of extraction of MUC5AC from Schirmer strips, linearity of dilution, limit of quantification, calibration range, and intra-assay and inter-assay reproducibility were examined. RESULTS: MUC5AC was extracted using polysorbate 20 in a concentration-dependent manner. Extraction was more efficient at 37°C than at 25°C. The signal-to-noise ratio of the assay was dramatically increased by treatment with neuraminidase A. Treatment with a blocking reagent before incubation produced good linearity of dilution. The inter-assay and intra-assay coefficients of variation were ≤16.6%. The relative error was within 13%. CONCLUSION: We developed an efficient method for extraction of MUC5AC from Schirmer strips and a highly sensitive, reliable assay for MUC5AC in human tear samples using a commercially available ELISA kit. This method will aid in our understanding of the pathophysiology of dry eye, assessment of the effects of treatment in daily practice, and selection of appropriate therapeutic agents for patients. Dove Medical Press 2018-08-29 /pmc/articles/PMC6120569/ /pubmed/30214141 http://dx.doi.org/10.2147/OPTH.S170552 Text en © 2018 Miyake et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Miyake, Hideki
Mori, Naoto
Mano, Hidetoshi
Imanaka, Takahiro
Nakamura, Masatsugu
Development of a highly sensitive and reliable enzyme-linked immunosorbent assay for MUC5AC in human tears extracted from Schirmer strips
title Development of a highly sensitive and reliable enzyme-linked immunosorbent assay for MUC5AC in human tears extracted from Schirmer strips
title_full Development of a highly sensitive and reliable enzyme-linked immunosorbent assay for MUC5AC in human tears extracted from Schirmer strips
title_fullStr Development of a highly sensitive and reliable enzyme-linked immunosorbent assay for MUC5AC in human tears extracted from Schirmer strips
title_full_unstemmed Development of a highly sensitive and reliable enzyme-linked immunosorbent assay for MUC5AC in human tears extracted from Schirmer strips
title_short Development of a highly sensitive and reliable enzyme-linked immunosorbent assay for MUC5AC in human tears extracted from Schirmer strips
title_sort development of a highly sensitive and reliable enzyme-linked immunosorbent assay for muc5ac in human tears extracted from schirmer strips
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6120569/
https://www.ncbi.nlm.nih.gov/pubmed/30214141
http://dx.doi.org/10.2147/OPTH.S170552
work_keys_str_mv AT miyakehideki developmentofahighlysensitiveandreliableenzymelinkedimmunosorbentassayformuc5acinhumantearsextractedfromschirmerstrips
AT morinaoto developmentofahighlysensitiveandreliableenzymelinkedimmunosorbentassayformuc5acinhumantearsextractedfromschirmerstrips
AT manohidetoshi developmentofahighlysensitiveandreliableenzymelinkedimmunosorbentassayformuc5acinhumantearsextractedfromschirmerstrips
AT imanakatakahiro developmentofahighlysensitiveandreliableenzymelinkedimmunosorbentassayformuc5acinhumantearsextractedfromschirmerstrips
AT nakamuramasatsugu developmentofahighlysensitiveandreliableenzymelinkedimmunosorbentassayformuc5acinhumantearsextractedfromschirmerstrips