Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery

Background and objective: Hypotension and bradycardia are the most common hemodynamic disorders and side effects of spinal anesthesia (SA) on the cardiovascular system. SA-induced sympathetic denervation causes peripheral vasodilatation and redistribution of central blood volume that may lead to dec...

Descripción completa

Detalles Bibliográficos
Autores principales: Mačiulienė, Asta, Gelmanas, Arūnas, Jaremko, Inna, Tamošiūnas, Ramūnas, Smailys, Alfredas, Macas, Andrius
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6122100/
https://www.ncbi.nlm.nih.gov/pubmed/30344280
http://dx.doi.org/10.3390/medicina54030049
_version_ 1783352582891110400
author Mačiulienė, Asta
Gelmanas, Arūnas
Jaremko, Inna
Tamošiūnas, Ramūnas
Smailys, Alfredas
Macas, Andrius
author_facet Mačiulienė, Asta
Gelmanas, Arūnas
Jaremko, Inna
Tamošiūnas, Ramūnas
Smailys, Alfredas
Macas, Andrius
author_sort Mačiulienė, Asta
collection PubMed
description Background and objective: Hypotension and bradycardia are the most common hemodynamic disorders and side effects of spinal anesthesia (SA) on the cardiovascular system. SA-induced sympathetic denervation causes peripheral vasodilatation and redistribution of central blood volume that may lead to decreased venous return to the heart. The aim of the study was to evaluate the changes of inferior vena cava collapsibility index (IVC-CI) during SA in spontaneously breathing patients during elective knee joint replacement surgery to prognose manifestation of intraoperative hypotension and bradycardia. Materials and methods: 60 patients (American Society of Anesthesiologists (ASA) physical status I or II, no clinically significant cardiovascular pathology) of both sexes undergoing elective knee joint replacement surgery under SA were included in the prospective study. Inspiratory and expiratory inferior vena cava (IVCin, IVCex) diameters were measured using an ultrasound device in supine position before and immediately after SA, then 15 min, 30 min, and 45 min after SA was performed. The heart rate, along with systolic, diastolic, and mean arterial blood pressures were collected. The parameters were measured at the baseline and at the next four time points. Results: There were no significant changes in IVCin, IVCex, and IVC-CI compared to baseline and other time point measurements in hypotensive versus nonhypotensive and bradycardic versus nonbradycardic patients (p > 0.05). Changes in IVC diameter do not prognose hypotension and/or bradycardia during SA: the area under the curve (AUC) of the receiver operating characteristic (ROC) curve for IVC-CI at all measuring points was <0.7, p > 0.05. Conclusions: Reduction in IVC diameters and increase in IVC-CI do not predict hypotension and bradycardia during SA in spontaneously breathing patients undergoing elective knee joint replacement surgery.
format Online
Article
Text
id pubmed-6122100
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61221002018-10-18 Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery Mačiulienė, Asta Gelmanas, Arūnas Jaremko, Inna Tamošiūnas, Ramūnas Smailys, Alfredas Macas, Andrius Medicina (Kaunas) Article Background and objective: Hypotension and bradycardia are the most common hemodynamic disorders and side effects of spinal anesthesia (SA) on the cardiovascular system. SA-induced sympathetic denervation causes peripheral vasodilatation and redistribution of central blood volume that may lead to decreased venous return to the heart. The aim of the study was to evaluate the changes of inferior vena cava collapsibility index (IVC-CI) during SA in spontaneously breathing patients during elective knee joint replacement surgery to prognose manifestation of intraoperative hypotension and bradycardia. Materials and methods: 60 patients (American Society of Anesthesiologists (ASA) physical status I or II, no clinically significant cardiovascular pathology) of both sexes undergoing elective knee joint replacement surgery under SA were included in the prospective study. Inspiratory and expiratory inferior vena cava (IVCin, IVCex) diameters were measured using an ultrasound device in supine position before and immediately after SA, then 15 min, 30 min, and 45 min after SA was performed. The heart rate, along with systolic, diastolic, and mean arterial blood pressures were collected. The parameters were measured at the baseline and at the next four time points. Results: There were no significant changes in IVCin, IVCex, and IVC-CI compared to baseline and other time point measurements in hypotensive versus nonhypotensive and bradycardic versus nonbradycardic patients (p > 0.05). Changes in IVC diameter do not prognose hypotension and/or bradycardia during SA: the area under the curve (AUC) of the receiver operating characteristic (ROC) curve for IVC-CI at all measuring points was <0.7, p > 0.05. Conclusions: Reduction in IVC diameters and increase in IVC-CI do not predict hypotension and bradycardia during SA in spontaneously breathing patients undergoing elective knee joint replacement surgery. MDPI 2018-07-12 /pmc/articles/PMC6122100/ /pubmed/30344280 http://dx.doi.org/10.3390/medicina54030049 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mačiulienė, Asta
Gelmanas, Arūnas
Jaremko, Inna
Tamošiūnas, Ramūnas
Smailys, Alfredas
Macas, Andrius
Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery
title Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery
title_full Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery
title_fullStr Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery
title_full_unstemmed Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery
title_short Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery
title_sort measurements of inferior vena cava diameter for prediction of hypotension and bradycardia during spinal anesthesia in spontaneously breathing patients during elective knee joint replacement surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6122100/
https://www.ncbi.nlm.nih.gov/pubmed/30344280
http://dx.doi.org/10.3390/medicina54030049
work_keys_str_mv AT maciulieneasta measurementsofinferiorvenacavadiameterforpredictionofhypotensionandbradycardiaduringspinalanesthesiainspontaneouslybreathingpatientsduringelectivekneejointreplacementsurgery
AT gelmanasarunas measurementsofinferiorvenacavadiameterforpredictionofhypotensionandbradycardiaduringspinalanesthesiainspontaneouslybreathingpatientsduringelectivekneejointreplacementsurgery
AT jaremkoinna measurementsofinferiorvenacavadiameterforpredictionofhypotensionandbradycardiaduringspinalanesthesiainspontaneouslybreathingpatientsduringelectivekneejointreplacementsurgery
AT tamosiunasramunas measurementsofinferiorvenacavadiameterforpredictionofhypotensionandbradycardiaduringspinalanesthesiainspontaneouslybreathingpatientsduringelectivekneejointreplacementsurgery
AT smailysalfredas measurementsofinferiorvenacavadiameterforpredictionofhypotensionandbradycardiaduringspinalanesthesiainspontaneouslybreathingpatientsduringelectivekneejointreplacementsurgery
AT macasandrius measurementsofinferiorvenacavadiameterforpredictionofhypotensionandbradycardiaduringspinalanesthesiainspontaneouslybreathingpatientsduringelectivekneejointreplacementsurgery