Cargando…
Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity
OBJECTIVE: This study was conducted to perform histomorphometric evaluations of the bone surrounding orthodontic miniscrews according to their proximity to the adjacent tooth roots in the posterior mandible of beagle dogs. METHODS: Four male beagle dogs were used for this study. Six orthodontic mini...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Association of Orthodontists
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123080/ https://www.ncbi.nlm.nih.gov/pubmed/30206527 http://dx.doi.org/10.4041/kjod.2018.48.5.283 |
_version_ | 1783352787538542592 |
---|---|
author | Oh, Hyun-Ju Cha, Jung-Yul Yu, Hyung-Seog Hwang, Chung-Ju |
author_facet | Oh, Hyun-Ju Cha, Jung-Yul Yu, Hyung-Seog Hwang, Chung-Ju |
author_sort | Oh, Hyun-Ju |
collection | PubMed |
description | OBJECTIVE: This study was conducted to perform histomorphometric evaluations of the bone surrounding orthodontic miniscrews according to their proximity to the adjacent tooth roots in the posterior mandible of beagle dogs. METHODS: Four male beagle dogs were used for this study. Six orthodontic miniscrews were placed in the interradicular spaces in the posterior mandible of each dog (n = 24). The implanted miniscrews were classified into no loading, immediate loading, and delayed loading groups according to the loading time. At 6 weeks after screw placement, the animals were sacrificed, and tissue blocks including the miniscrews were harvested for histological examinations. After analysis of the histological sections, the miniscrews were categorized into three additional groups according to the root proximity: high root proximity, low root proximity, and safe distance groups. Differences in the bone–implant contact (BIC, %) among the root proximity groups and loading time groups were determined using statistical analyses. RESULTS: No BIC was observed within the bundle bone invaded by the miniscrew threads. Narrowing of the periodontal ligament space was observed in cases where the miniscrew threads touched the bundle bone. BIC (%) was significantly lower in the high root proximity group than in the low root proximity and safe distance groups. However, BIC (%) showed no significant differences among the loading time groups. CONCLUSIONS: Regardless of the loading time, the stability of an orthodontic miniscrew is decreased if it is in contact with the bundle bone as well as the adjacent tooth root. |
format | Online Article Text |
id | pubmed-6123080 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Association of Orthodontists |
record_format | MEDLINE/PubMed |
spelling | pubmed-61230802018-09-11 Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity Oh, Hyun-Ju Cha, Jung-Yul Yu, Hyung-Seog Hwang, Chung-Ju Korean J Orthod Original Article OBJECTIVE: This study was conducted to perform histomorphometric evaluations of the bone surrounding orthodontic miniscrews according to their proximity to the adjacent tooth roots in the posterior mandible of beagle dogs. METHODS: Four male beagle dogs were used for this study. Six orthodontic miniscrews were placed in the interradicular spaces in the posterior mandible of each dog (n = 24). The implanted miniscrews were classified into no loading, immediate loading, and delayed loading groups according to the loading time. At 6 weeks after screw placement, the animals were sacrificed, and tissue blocks including the miniscrews were harvested for histological examinations. After analysis of the histological sections, the miniscrews were categorized into three additional groups according to the root proximity: high root proximity, low root proximity, and safe distance groups. Differences in the bone–implant contact (BIC, %) among the root proximity groups and loading time groups were determined using statistical analyses. RESULTS: No BIC was observed within the bundle bone invaded by the miniscrew threads. Narrowing of the periodontal ligament space was observed in cases where the miniscrew threads touched the bundle bone. BIC (%) was significantly lower in the high root proximity group than in the low root proximity and safe distance groups. However, BIC (%) showed no significant differences among the loading time groups. CONCLUSIONS: Regardless of the loading time, the stability of an orthodontic miniscrew is decreased if it is in contact with the bundle bone as well as the adjacent tooth root. Korean Association of Orthodontists 2018-09 2018-08-08 /pmc/articles/PMC6123080/ /pubmed/30206527 http://dx.doi.org/10.4041/kjod.2018.48.5.283 Text en © 2018 The Korean Association of Orthodontists. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Oh, Hyun-Ju Cha, Jung-Yul Yu, Hyung-Seog Hwang, Chung-Ju Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity |
title | Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity |
title_full | Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity |
title_fullStr | Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity |
title_full_unstemmed | Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity |
title_short | Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity |
title_sort | histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123080/ https://www.ncbi.nlm.nih.gov/pubmed/30206527 http://dx.doi.org/10.4041/kjod.2018.48.5.283 |
work_keys_str_mv | AT ohhyunju histomorphometricevaluationofthebonesurroundingorthodonticminiscrewsaccordingtotheiradjacentrootproximity AT chajungyul histomorphometricevaluationofthebonesurroundingorthodonticminiscrewsaccordingtotheiradjacentrootproximity AT yuhyungseog histomorphometricevaluationofthebonesurroundingorthodonticminiscrewsaccordingtotheiradjacentrootproximity AT hwangchungju histomorphometricevaluationofthebonesurroundingorthodonticminiscrewsaccordingtotheiradjacentrootproximity |