Cargando…
High‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator
PURPOSE: The major errors in HDR brachytherapy are related to treatment distance, almost all of which are caused by incorrect applicator information. The aim of this study is to propose a quick pretreatment verification method to evaluate channel length and dwell position with a transparent applicat...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123126/ https://www.ncbi.nlm.nih.gov/pubmed/29959815 http://dx.doi.org/10.1002/acm2.12405 |
_version_ | 1783352794284032000 |
---|---|
author | Otani, Yuki Sumida, Iori Nose, Takayuki Shimamoto, Shigetoshi Okubo, Hirofumi Ogawa, Kazuhiko |
author_facet | Otani, Yuki Sumida, Iori Nose, Takayuki Shimamoto, Shigetoshi Okubo, Hirofumi Ogawa, Kazuhiko |
author_sort | Otani, Yuki |
collection | PubMed |
description | PURPOSE: The major errors in HDR brachytherapy are related to treatment distance, almost all of which are caused by incorrect applicator information. The aim of this study is to propose a quick pretreatment verification method to evaluate channel length and dwell position with a transparent applicator, which, in addition, is suitable as an education tool to assist in the understanding of the applicator structure. METHODS: A transparent applicator model was fabricated using a three‐dimensional printer and transparent resin. Its aim is to be a replica of a real gynecological applicator. The pretreatment verification is performed by observing the planned dwell positions of a check cable inside a transparent applicator. A digital camera acquired images and the dwell positions of the radioactive source and check cable were evaluated by comparing them with respect to the theoretical dwell positions marked by the proper x‐ray marker. The potential effectiveness of verification using a transparent applicator was also evaluated using brachytherapy events reported in the literature. RESULTS: The transparent applicator closely resembles the real applicator in shape and had an error of less than 0.2 mm. The average dwell position displacement between the radioactive source and check cable was 0.4 mm. The analysis of brachytherapy events showed that channel‐length, dwell‐position, and step‐size errors made up 50% of all events, but affected 64% of all patients. CONCLUSIONS: The transparent applicator model enables a noninvasive, repeatable verification of the channel length and dwell positions to be performed before treatment. This verification has the potential to help prevent common errors in treatment delivery. In addition, the transparent applicator model can be used as a teaching tool to help clinicians understand the operation of the applicator, lowering the risk of events. |
format | Online Article Text |
id | pubmed-6123126 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-61231262018-09-10 High‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator Otani, Yuki Sumida, Iori Nose, Takayuki Shimamoto, Shigetoshi Okubo, Hirofumi Ogawa, Kazuhiko J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: The major errors in HDR brachytherapy are related to treatment distance, almost all of which are caused by incorrect applicator information. The aim of this study is to propose a quick pretreatment verification method to evaluate channel length and dwell position with a transparent applicator, which, in addition, is suitable as an education tool to assist in the understanding of the applicator structure. METHODS: A transparent applicator model was fabricated using a three‐dimensional printer and transparent resin. Its aim is to be a replica of a real gynecological applicator. The pretreatment verification is performed by observing the planned dwell positions of a check cable inside a transparent applicator. A digital camera acquired images and the dwell positions of the radioactive source and check cable were evaluated by comparing them with respect to the theoretical dwell positions marked by the proper x‐ray marker. The potential effectiveness of verification using a transparent applicator was also evaluated using brachytherapy events reported in the literature. RESULTS: The transparent applicator closely resembles the real applicator in shape and had an error of less than 0.2 mm. The average dwell position displacement between the radioactive source and check cable was 0.4 mm. The analysis of brachytherapy events showed that channel‐length, dwell‐position, and step‐size errors made up 50% of all events, but affected 64% of all patients. CONCLUSIONS: The transparent applicator model enables a noninvasive, repeatable verification of the channel length and dwell positions to be performed before treatment. This verification has the potential to help prevent common errors in treatment delivery. In addition, the transparent applicator model can be used as a teaching tool to help clinicians understand the operation of the applicator, lowering the risk of events. John Wiley and Sons Inc. 2018-06-30 /pmc/articles/PMC6123126/ /pubmed/29959815 http://dx.doi.org/10.1002/acm2.12405 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Otani, Yuki Sumida, Iori Nose, Takayuki Shimamoto, Shigetoshi Okubo, Hirofumi Ogawa, Kazuhiko High‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator |
title | High‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator |
title_full | High‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator |
title_fullStr | High‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator |
title_full_unstemmed | High‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator |
title_short | High‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator |
title_sort | high‐dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123126/ https://www.ncbi.nlm.nih.gov/pubmed/29959815 http://dx.doi.org/10.1002/acm2.12405 |
work_keys_str_mv | AT otaniyuki highdoserateintracavitarybrachytherapypretreatmentdwellpositionverificationusingatransparentapplicator AT sumidaiori highdoserateintracavitarybrachytherapypretreatmentdwellpositionverificationusingatransparentapplicator AT nosetakayuki highdoserateintracavitarybrachytherapypretreatmentdwellpositionverificationusingatransparentapplicator AT shimamotoshigetoshi highdoserateintracavitarybrachytherapypretreatmentdwellpositionverificationusingatransparentapplicator AT okubohirofumi highdoserateintracavitarybrachytherapypretreatmentdwellpositionverificationusingatransparentapplicator AT ogawakazuhiko highdoserateintracavitarybrachytherapypretreatmentdwellpositionverificationusingatransparentapplicator |