Cargando…

Accuracy of TomoEDGE dynamic jaw field widths

Dynamic jaw delivery on the TomoTherapy H‐series platform, entitled TomoEDGE™, is an effective tool to decrease the patient dose along the superior and inferior edges of the treatment target. The aperture of the TomoTherapy jaws, that is, field width (FW), defines the longitudinal dose profile. A co...

Descripción completa

Detalles Bibliográficos
Autores principales: Urso, Patrizia, Corradini, Nathan A., Vite, Cristina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123137/
https://www.ncbi.nlm.nih.gov/pubmed/30058267
http://dx.doi.org/10.1002/acm2.12418
_version_ 1783352796815294464
author Urso, Patrizia
Corradini, Nathan A.
Vite, Cristina
author_facet Urso, Patrizia
Corradini, Nathan A.
Vite, Cristina
author_sort Urso, Patrizia
collection PubMed
description Dynamic jaw delivery on the TomoTherapy H‐series platform, entitled TomoEDGE™, is an effective tool to decrease the patient dose along the superior and inferior edges of the treatment target. The aperture of the TomoTherapy jaws, that is, field width (FW), defines the longitudinal dose profile. A consistent FW dose profile is an important quantity for accurate and reproducible dose delivery in TomoTherapy. To date, no evaluation has been made of the accuracy and precision of the dose profiles produced by dynamic jaws. This study aims to provide a long‐term evaluation of the dynamic jaw FW dose profiles obtained on TomoTherapy utilizing the TomoTherapy Quality Assurance procedure (TQA). A total of 840 dose profiles were measured during 84 TQA procedures, performed over a 2‐yr period. The full width at half maximum (FWHM) and constancy of the FW dose profile measurements were analyzed and compared with the tolerances proposed by AAPM Task Group 148 (TG‐148) and those used by the manufacturer. The FWHM evaluation showed that the FWs > 2.0 cm respect the TG‐148 tolerance of 1%, while the asymmetric FWs ≤ 2.0 cm were outside the limit in 17.3% of measurements. Constancy results evaluated along the full profiles showed that 95.2% of measurements were within 3% of the baseline for symmetric FWs and 94.8% of measurements were within 4% of the baseline for asymmetric FWs. In conclusion, the analysis confirms the accuracy and precision of TomoEDGE™ technology in jaw positioning. This study has identified the potential to establish an appropriate QA tolerance for the asymmetric FWs used in dynamic jaw movement. Finally, the clinical significance of the observed discrepancies should be studied further to understand the dosimetric effect on patient treatments.
format Online
Article
Text
id pubmed-6123137
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-61231372018-09-10 Accuracy of TomoEDGE dynamic jaw field widths Urso, Patrizia Corradini, Nathan A. Vite, Cristina J Appl Clin Med Phys Technical Notes Dynamic jaw delivery on the TomoTherapy H‐series platform, entitled TomoEDGE™, is an effective tool to decrease the patient dose along the superior and inferior edges of the treatment target. The aperture of the TomoTherapy jaws, that is, field width (FW), defines the longitudinal dose profile. A consistent FW dose profile is an important quantity for accurate and reproducible dose delivery in TomoTherapy. To date, no evaluation has been made of the accuracy and precision of the dose profiles produced by dynamic jaws. This study aims to provide a long‐term evaluation of the dynamic jaw FW dose profiles obtained on TomoTherapy utilizing the TomoTherapy Quality Assurance procedure (TQA). A total of 840 dose profiles were measured during 84 TQA procedures, performed over a 2‐yr period. The full width at half maximum (FWHM) and constancy of the FW dose profile measurements were analyzed and compared with the tolerances proposed by AAPM Task Group 148 (TG‐148) and those used by the manufacturer. The FWHM evaluation showed that the FWs > 2.0 cm respect the TG‐148 tolerance of 1%, while the asymmetric FWs ≤ 2.0 cm were outside the limit in 17.3% of measurements. Constancy results evaluated along the full profiles showed that 95.2% of measurements were within 3% of the baseline for symmetric FWs and 94.8% of measurements were within 4% of the baseline for asymmetric FWs. In conclusion, the analysis confirms the accuracy and precision of TomoEDGE™ technology in jaw positioning. This study has identified the potential to establish an appropriate QA tolerance for the asymmetric FWs used in dynamic jaw movement. Finally, the clinical significance of the observed discrepancies should be studied further to understand the dosimetric effect on patient treatments. John Wiley and Sons Inc. 2018-07-29 /pmc/articles/PMC6123137/ /pubmed/30058267 http://dx.doi.org/10.1002/acm2.12418 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Urso, Patrizia
Corradini, Nathan A.
Vite, Cristina
Accuracy of TomoEDGE dynamic jaw field widths
title Accuracy of TomoEDGE dynamic jaw field widths
title_full Accuracy of TomoEDGE dynamic jaw field widths
title_fullStr Accuracy of TomoEDGE dynamic jaw field widths
title_full_unstemmed Accuracy of TomoEDGE dynamic jaw field widths
title_short Accuracy of TomoEDGE dynamic jaw field widths
title_sort accuracy of tomoedge dynamic jaw field widths
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123137/
https://www.ncbi.nlm.nih.gov/pubmed/30058267
http://dx.doi.org/10.1002/acm2.12418
work_keys_str_mv AT ursopatrizia accuracyoftomoedgedynamicjawfieldwidths
AT corradininathana accuracyoftomoedgedynamicjawfieldwidths
AT vitecristina accuracyoftomoedgedynamicjawfieldwidths