Cargando…

Early detection of potential errors during patient treatment planning

PURPOSE: Data errors caught late in treatment planning require time to correct, resulting in delays up to 1 week. In this work, we identify causes of data errors in treatment planning and develop a software tool that detects them early in the planning workflow. METHODS: Two categories of errors were...

Descripción completa

Detalles Bibliográficos
Autores principales: Lack, Danielle, Liang, Jian, Benedetti, Lisa, Knill, Cory, Yan, Di
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123146/
https://www.ncbi.nlm.nih.gov/pubmed/29978546
http://dx.doi.org/10.1002/acm2.12388
Descripción
Sumario:PURPOSE: Data errors caught late in treatment planning require time to correct, resulting in delays up to 1 week. In this work, we identify causes of data errors in treatment planning and develop a software tool that detects them early in the planning workflow. METHODS: Two categories of errors were studied: data transfer errors and TPS errors. Using root cause analysis, the causes of these errors were determined. This information was incorporated into a software tool which uses ODBC‐SQL service to access TPS's Postgres and Mosaiq MSSQL databases for our clinic. The tool then uses a read‐only FTP service to scan the TPS unix file system for errors. Detected errors are reviewed by a physicist. Once confirmed, clinicians are notified to correct the error and educated to prevent errors in the future. Time‐cost analysis was performed to estimate the time savings of implementing this software clinically. RESULTS: The main errors identified were incorrect patient entry, missing image slice, and incorrect DICOM tag for data transfer errors and incorrect CT‐density table application, incorrect image as reference CT, and secondary image imported to incorrect patient for TPS errors. The software has been running automatically since 2015. In 2016, 84 errors were detected with the most frequent errors being incorrect patient entry (35), incorrect CT‐density table (17), and missing image slice (16). After clinical interventions to our planning workflow, the number of errors in 2017 decreased to 44. Time savings in 2016 with the software is estimated to be 795 h. This is attributed to catching errors early and eliminating the need to replan cases. CONCLUSIONS: New QA software detects errors during planning, improving the accuracy and efficiency of the planning process. This important QA tool focused our efforts on the data communication processes in our planning workflow that need the most improvement.