Investigation of a source model for a new electronic brachytherapy tandem by film measurement

PURPOSE: To investigate the accuracy of a vendor‐supplied source model for a new Xoft Axxent 0‐degree titanium tandem by film measurement. METHODS: We measured the anisotropy factors at varying distances and angles from the tandem in water using radiochromic film (Gafchromic EBT3) and an Epson Perfe...

Descripción completa

Detalles Bibliográficos
Autores principales: Martin, Elijah, Sowards, Keith, Wang, Brian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123150/
https://www.ncbi.nlm.nih.gov/pubmed/30105891
http://dx.doi.org/10.1002/acm2.12440
_version_ 1783352799898107904
author Martin, Elijah
Sowards, Keith
Wang, Brian
author_facet Martin, Elijah
Sowards, Keith
Wang, Brian
author_sort Martin, Elijah
collection PubMed
description PURPOSE: To investigate the accuracy of a vendor‐supplied source model for a new Xoft Axxent 0‐degree titanium tandem by film measurement. METHODS: We measured the anisotropy factors at varying distances and angles from the tandem in water using radiochromic film (Gafchromic EBT3) and an Epson Perfection v750 desktop flatbed scanner (US Epson, Long Beach, CA). A 0‐degree tandem was placed vertically in a water phantom. Four pieces of film, each at varying depths, were positioned orthogonal to the longitudinal axis of the tandem for azimuthal anisotropy measurements. Polar anisotropy measurements were taken with the film aligned parallel to the tandem. An absolute dose calibration for the film was verified with a PTW 34013 Soft X‐Ray Chamber. The film measurements were analyzed using different color channels. The measured polar anisotropy for varying source positions was compared to the vendor's data. Azimuthal anisotropy was measured as a function of the radius and angle, and normalized to the mean value over all angles at the specified radius. RESULTS: The azimuthal anisotropy of the tandem and source was found to be consistent for different positions along the tandem's longitudinal axis and at varying distances from the tandem. Absolute dose using a calibrated parallel plate chamber showed agreement to within 2% of expected TPS values. The custom tandem, which has a thicker tip than the wall, was attenuating the 50 kV photons more than expected, at the angles where the photons had more wall material to traverse. This discrepancy was verified at different distances from the tandem and with different measurement techniques. As distance increased, anisotropy values had better agreement. CONCLUSIONS: We quantified the agreement between the measured and provided anisotropy factors for a new Xoft Axxent 0‐degree titanium tandem. Radiochromic film response at low kV energy was also investigated. Our results showed that vendor‐supplied TG‐43 values were appropriate for clinical use at majority of the angles. A rigorous quality assurance method for new electronic brachytherapy sources and applicators, along with complete knowledge of all dosimetric measuring tools, should be implemented for all parts of the verification and commissioning process.
format Online
Article
Text
id pubmed-6123150
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-61231502018-09-10 Investigation of a source model for a new electronic brachytherapy tandem by film measurement Martin, Elijah Sowards, Keith Wang, Brian J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To investigate the accuracy of a vendor‐supplied source model for a new Xoft Axxent 0‐degree titanium tandem by film measurement. METHODS: We measured the anisotropy factors at varying distances and angles from the tandem in water using radiochromic film (Gafchromic EBT3) and an Epson Perfection v750 desktop flatbed scanner (US Epson, Long Beach, CA). A 0‐degree tandem was placed vertically in a water phantom. Four pieces of film, each at varying depths, were positioned orthogonal to the longitudinal axis of the tandem for azimuthal anisotropy measurements. Polar anisotropy measurements were taken with the film aligned parallel to the tandem. An absolute dose calibration for the film was verified with a PTW 34013 Soft X‐Ray Chamber. The film measurements were analyzed using different color channels. The measured polar anisotropy for varying source positions was compared to the vendor's data. Azimuthal anisotropy was measured as a function of the radius and angle, and normalized to the mean value over all angles at the specified radius. RESULTS: The azimuthal anisotropy of the tandem and source was found to be consistent for different positions along the tandem's longitudinal axis and at varying distances from the tandem. Absolute dose using a calibrated parallel plate chamber showed agreement to within 2% of expected TPS values. The custom tandem, which has a thicker tip than the wall, was attenuating the 50 kV photons more than expected, at the angles where the photons had more wall material to traverse. This discrepancy was verified at different distances from the tandem and with different measurement techniques. As distance increased, anisotropy values had better agreement. CONCLUSIONS: We quantified the agreement between the measured and provided anisotropy factors for a new Xoft Axxent 0‐degree titanium tandem. Radiochromic film response at low kV energy was also investigated. Our results showed that vendor‐supplied TG‐43 values were appropriate for clinical use at majority of the angles. A rigorous quality assurance method for new electronic brachytherapy sources and applicators, along with complete knowledge of all dosimetric measuring tools, should be implemented for all parts of the verification and commissioning process. John Wiley and Sons Inc. 2018-08-13 /pmc/articles/PMC6123150/ /pubmed/30105891 http://dx.doi.org/10.1002/acm2.12440 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Martin, Elijah
Sowards, Keith
Wang, Brian
Investigation of a source model for a new electronic brachytherapy tandem by film measurement
title Investigation of a source model for a new electronic brachytherapy tandem by film measurement
title_full Investigation of a source model for a new electronic brachytherapy tandem by film measurement
title_fullStr Investigation of a source model for a new electronic brachytherapy tandem by film measurement
title_full_unstemmed Investigation of a source model for a new electronic brachytherapy tandem by film measurement
title_short Investigation of a source model for a new electronic brachytherapy tandem by film measurement
title_sort investigation of a source model for a new electronic brachytherapy tandem by film measurement
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123150/
https://www.ncbi.nlm.nih.gov/pubmed/30105891
http://dx.doi.org/10.1002/acm2.12440
work_keys_str_mv AT martinelijah investigationofasourcemodelforanewelectronicbrachytherapytandembyfilmmeasurement
AT sowardskeith investigationofasourcemodelforanewelectronicbrachytherapytandembyfilmmeasurement
AT wangbrian investigationofasourcemodelforanewelectronicbrachytherapytandembyfilmmeasurement