Cargando…

Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes

Radiotherapy to the breast after surgery sometimes requires adjoining nodes to be included in the treatment volume. In these cases, the traditional approach has been a complex 3‐Dimensional Conformal Radiotherapy (3DCRT) beam arrangement which can result in significant dose heterogeneity at the beam...

Descripción completa

Detalles Bibliográficos
Autores principales: Byrne, Mikel, Archibald‐Heeren, Ben, Hu, Yunfei, Fong, Andrew, Chong, Leena, Teh, Amy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123166/
https://www.ncbi.nlm.nih.gov/pubmed/30125454
http://dx.doi.org/10.1002/acm2.12442
_version_ 1783352803412934656
author Byrne, Mikel
Archibald‐Heeren, Ben
Hu, Yunfei
Fong, Andrew
Chong, Leena
Teh, Amy
author_facet Byrne, Mikel
Archibald‐Heeren, Ben
Hu, Yunfei
Fong, Andrew
Chong, Leena
Teh, Amy
author_sort Byrne, Mikel
collection PubMed
description Radiotherapy to the breast after surgery sometimes requires adjoining nodes to be included in the treatment volume. In these cases, the traditional approach has been a complex 3‐Dimensional Conformal Radiotherapy (3DCRT) beam arrangement which can result in significant dose heterogeneity at the beam junctions. A Volumetric Modulated Arc Therapy (VMAT) beam arrangement has previously been proposed for breast cases, where the chest wall/breast is treated with a limited angle (partial arc) tangential VMAT technique (Virén et al. [2015] Radiat Oncol. 10:79). In our study, this approach is extended to breast and chest wall cases with adjoining nodes by adding a separate conventional VMAT arc field specifically limited to the superior nodes. This VMAT method was implemented using a semiautomated approach on 27 patients, and the resultant plan compared to a monoisocentric 3DCRT plan. Plan statistics, Dose‐Volume Histogram (DVH) analysis and Radiation Oncologist (RO) preference were assessed. When compared to the 3DCRT technique, the VMAT planning method was found to result in better target volume coverage, high doses to organs at risk (OAR) were reduced but greater OAR volumes received low doses. Having said that, the volume receiving low doses with this tangential VMAT technique was less than that of other VMAT planning methods described in the literature, and the integral dose was less than the 3DCRT method. The VMAT technique also resulted in more robust junction doses that the 3DCRT method. RO review found that the VMAT technique was preferred in 81% of cases. Specifically, the VMAT plans were preferred in all categories of patients except left chest wall cases where the intermammary nodes were also treated. The VMAT technique described here is a useful addition to the treatment options available for breast/chest wall and nodal patients.
format Online
Article
Text
id pubmed-6123166
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-61231662018-09-10 Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes Byrne, Mikel Archibald‐Heeren, Ben Hu, Yunfei Fong, Andrew Chong, Leena Teh, Amy J Appl Clin Med Phys Radiation Oncology Physics Radiotherapy to the breast after surgery sometimes requires adjoining nodes to be included in the treatment volume. In these cases, the traditional approach has been a complex 3‐Dimensional Conformal Radiotherapy (3DCRT) beam arrangement which can result in significant dose heterogeneity at the beam junctions. A Volumetric Modulated Arc Therapy (VMAT) beam arrangement has previously been proposed for breast cases, where the chest wall/breast is treated with a limited angle (partial arc) tangential VMAT technique (Virén et al. [2015] Radiat Oncol. 10:79). In our study, this approach is extended to breast and chest wall cases with adjoining nodes by adding a separate conventional VMAT arc field specifically limited to the superior nodes. This VMAT method was implemented using a semiautomated approach on 27 patients, and the resultant plan compared to a monoisocentric 3DCRT plan. Plan statistics, Dose‐Volume Histogram (DVH) analysis and Radiation Oncologist (RO) preference were assessed. When compared to the 3DCRT technique, the VMAT planning method was found to result in better target volume coverage, high doses to organs at risk (OAR) were reduced but greater OAR volumes received low doses. Having said that, the volume receiving low doses with this tangential VMAT technique was less than that of other VMAT planning methods described in the literature, and the integral dose was less than the 3DCRT method. The VMAT technique also resulted in more robust junction doses that the 3DCRT method. RO review found that the VMAT technique was preferred in 81% of cases. Specifically, the VMAT plans were preferred in all categories of patients except left chest wall cases where the intermammary nodes were also treated. The VMAT technique described here is a useful addition to the treatment options available for breast/chest wall and nodal patients. John Wiley and Sons Inc. 2018-08-19 /pmc/articles/PMC6123166/ /pubmed/30125454 http://dx.doi.org/10.1002/acm2.12442 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Byrne, Mikel
Archibald‐Heeren, Ben
Hu, Yunfei
Fong, Andrew
Chong, Leena
Teh, Amy
Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes
title Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes
title_full Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes
title_fullStr Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes
title_full_unstemmed Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes
title_short Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes
title_sort comparison of semiautomated tangential vmat with 3dcrt for breast or chest wall and regional nodes
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123166/
https://www.ncbi.nlm.nih.gov/pubmed/30125454
http://dx.doi.org/10.1002/acm2.12442
work_keys_str_mv AT byrnemikel comparisonofsemiautomatedtangentialvmatwith3dcrtforbreastorchestwallandregionalnodes
AT archibaldheerenben comparisonofsemiautomatedtangentialvmatwith3dcrtforbreastorchestwallandregionalnodes
AT huyunfei comparisonofsemiautomatedtangentialvmatwith3dcrtforbreastorchestwallandregionalnodes
AT fongandrew comparisonofsemiautomatedtangentialvmatwith3dcrtforbreastorchestwallandregionalnodes
AT chongleena comparisonofsemiautomatedtangentialvmatwith3dcrtforbreastorchestwallandregionalnodes
AT tehamy comparisonofsemiautomatedtangentialvmatwith3dcrtforbreastorchestwallandregionalnodes