Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures
Modular femoral prostheses are characterized by a second neck-stem junction. This modularity provides many clinical benefits including hip offset restoration, intraoperative leg length and anteversion adjustment. Although, this extra junction in modular femoral prostheses can contribute to catastrop...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Hip Society
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123507/ https://www.ncbi.nlm.nih.gov/pubmed/30202754 http://dx.doi.org/10.5371/hp.2018.30.3.190 |
_version_ | 1783352852668743680 |
---|---|
author | Papaioannou, Ioannis Repantis, Thomas Baikousis, Andreas Korovessis, Panagiotis |
author_facet | Papaioannou, Ioannis Repantis, Thomas Baikousis, Andreas Korovessis, Panagiotis |
author_sort | Papaioannou, Ioannis |
collection | PubMed |
description | Modular femoral prostheses are characterized by a second neck-stem junction. This modularity provides many clinical benefits including hip offset restoration, intraoperative leg length and anteversion adjustment. Although, this extra junction in modular femoral prostheses can contribute to catastrophic consequences like fracture, cold welding, corrosion and fretting of the modularity. However, only few complications related to the modularity itself have been reported in the literature. We report a unique case of neck-stem component dissociation without dislocation of the R-120PC™ Modular Stem (DJO Surgical). Our 71-year-old obese female patient underwent cementless hip replacement 5 years ago. Following radiographic confirmation of neck-stem dissociation open reduction was performed and wiring fixation was applied to secure the neck to the stem. After reduction and fixation, hip joint was stable, and our patient returned to her daily routine 2.5 months postoperatively. The last follow up was at 12 months after surgery with excellent radiographic and clinical evaluation. |
format | Online Article Text |
id | pubmed-6123507 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Hip Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-61235072018-09-10 Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures Papaioannou, Ioannis Repantis, Thomas Baikousis, Andreas Korovessis, Panagiotis Hip Pelvis Case Report Modular femoral prostheses are characterized by a second neck-stem junction. This modularity provides many clinical benefits including hip offset restoration, intraoperative leg length and anteversion adjustment. Although, this extra junction in modular femoral prostheses can contribute to catastrophic consequences like fracture, cold welding, corrosion and fretting of the modularity. However, only few complications related to the modularity itself have been reported in the literature. We report a unique case of neck-stem component dissociation without dislocation of the R-120PC™ Modular Stem (DJO Surgical). Our 71-year-old obese female patient underwent cementless hip replacement 5 years ago. Following radiographic confirmation of neck-stem dissociation open reduction was performed and wiring fixation was applied to secure the neck to the stem. After reduction and fixation, hip joint was stable, and our patient returned to her daily routine 2.5 months postoperatively. The last follow up was at 12 months after surgery with excellent radiographic and clinical evaluation. Korean Hip Society 2018-09 2018-09-04 /pmc/articles/PMC6123507/ /pubmed/30202754 http://dx.doi.org/10.5371/hp.2018.30.3.190 Text en Copyright © 2018 by Korean Hip Society http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Papaioannou, Ioannis Repantis, Thomas Baikousis, Andreas Korovessis, Panagiotis Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures |
title | Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures |
title_full | Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures |
title_fullStr | Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures |
title_full_unstemmed | Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures |
title_short | Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures |
title_sort | late onset disassembly of a modular neck-stem component after cementless hip replacement without dislocation: a case report and review of literatures |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6123507/ https://www.ncbi.nlm.nih.gov/pubmed/30202754 http://dx.doi.org/10.5371/hp.2018.30.3.190 |
work_keys_str_mv | AT papaioannouioannis lateonsetdisassemblyofamodularneckstemcomponentaftercementlesshipreplacementwithoutdislocationacasereportandreviewofliteratures AT repantisthomas lateonsetdisassemblyofamodularneckstemcomponentaftercementlesshipreplacementwithoutdislocationacasereportandreviewofliteratures AT baikousisandreas lateonsetdisassemblyofamodularneckstemcomponentaftercementlesshipreplacementwithoutdislocationacasereportandreviewofliteratures AT korovessispanagiotis lateonsetdisassemblyofamodularneckstemcomponentaftercementlesshipreplacementwithoutdislocationacasereportandreviewofliteratures |