Cargando…

Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis

OBJECTIVE: This meta-analysis was performed to evaluate the safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture. METHODS: We searched Embase, PubMed, the Cochrane Library, Web of Science, and China National Knowledge Infrastructure for relevant randomize...

Descripción completa

Detalles Bibliográficos
Autores principales: Miao, Shuai, Wang, Xiuli, Zou, Lan, Zhao, Ye, Wang, Guanglei, Liu, Yuepeng, Liu, Su
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6124295/
https://www.ncbi.nlm.nih.gov/pubmed/29619861
http://dx.doi.org/10.1177/0300060518765344
_version_ 1783353013387132928
author Miao, Shuai
Wang, Xiuli
Zou, Lan
Zhao, Ye
Wang, Guanglei
Liu, Yuepeng
Liu, Su
author_facet Miao, Shuai
Wang, Xiuli
Zou, Lan
Zhao, Ye
Wang, Guanglei
Liu, Yuepeng
Liu, Su
author_sort Miao, Shuai
collection PubMed
description OBJECTIVE: This meta-analysis was performed to evaluate the safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture. METHODS: We searched Embase, PubMed, the Cochrane Library, Web of Science, and China National Knowledge Infrastructure for relevant randomized clinical trials comparing the oblique axis with the short axis in ultrasound-guided internal jugular vein puncture. RESULTS: Five randomized clinical trials were included in this meta-analysis. The pooled meta-analysis showed that the incidence of arterial puncture in the oblique-axis group was significantly lower than that in the short-axis group. No significant difference was found in the first-pass success rate between the oblique-axis group and short-axis group. Additionally, there were no significant differences in the puncture success rate or number of attempts required between the two groups. CONCLUSION: Ultrasound-guided internal jugular vein puncture using the oblique-axis plane reduced the risk of arterial puncture, but no difference was found in the first-pass success rate, puncture success rate, or number of attempts required.
format Online
Article
Text
id pubmed-6124295
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-61242952018-09-10 Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis Miao, Shuai Wang, Xiuli Zou, Lan Zhao, Ye Wang, Guanglei Liu, Yuepeng Liu, Su J Int Med Res Clinical Research Reports OBJECTIVE: This meta-analysis was performed to evaluate the safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture. METHODS: We searched Embase, PubMed, the Cochrane Library, Web of Science, and China National Knowledge Infrastructure for relevant randomized clinical trials comparing the oblique axis with the short axis in ultrasound-guided internal jugular vein puncture. RESULTS: Five randomized clinical trials were included in this meta-analysis. The pooled meta-analysis showed that the incidence of arterial puncture in the oblique-axis group was significantly lower than that in the short-axis group. No significant difference was found in the first-pass success rate between the oblique-axis group and short-axis group. Additionally, there were no significant differences in the puncture success rate or number of attempts required between the two groups. CONCLUSION: Ultrasound-guided internal jugular vein puncture using the oblique-axis plane reduced the risk of arterial puncture, but no difference was found in the first-pass success rate, puncture success rate, or number of attempts required. SAGE Publications 2018-04-05 2018-07 /pmc/articles/PMC6124295/ /pubmed/29619861 http://dx.doi.org/10.1177/0300060518765344 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Clinical Research Reports
Miao, Shuai
Wang, Xiuli
Zou, Lan
Zhao, Ye
Wang, Guanglei
Liu, Yuepeng
Liu, Su
Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis
title Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis
title_full Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis
title_fullStr Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis
title_full_unstemmed Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis
title_short Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis
title_sort safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: a meta-analysis
topic Clinical Research Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6124295/
https://www.ncbi.nlm.nih.gov/pubmed/29619861
http://dx.doi.org/10.1177/0300060518765344
work_keys_str_mv AT miaoshuai safetyandefficacyoftheobliqueaxisplaneinultrasoundguidedinternaljugularveinpunctureametaanalysis
AT wangxiuli safetyandefficacyoftheobliqueaxisplaneinultrasoundguidedinternaljugularveinpunctureametaanalysis
AT zoulan safetyandefficacyoftheobliqueaxisplaneinultrasoundguidedinternaljugularveinpunctureametaanalysis
AT zhaoye safetyandefficacyoftheobliqueaxisplaneinultrasoundguidedinternaljugularveinpunctureametaanalysis
AT wangguanglei safetyandefficacyoftheobliqueaxisplaneinultrasoundguidedinternaljugularveinpunctureametaanalysis
AT liuyuepeng safetyandefficacyoftheobliqueaxisplaneinultrasoundguidedinternaljugularveinpunctureametaanalysis
AT liusu safetyandefficacyoftheobliqueaxisplaneinultrasoundguidedinternaljugularveinpunctureametaanalysis