Cargando…

Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes

A dysfunctional vestibular system can be a severe detriment to the quality of life of a patient. Recent studies have shown the feasibility for a vestibular implant to restore rotational sensation via electrical stimulation of vestibular ampullary nerves. However, the optimal stimulation site for sel...

Descripción completa

Detalles Bibliográficos
Autores principales: Schier, Peter, Handler, Michael, Johnson Chacko, Lejo, Schrott-Fischer, Anneliese, Fritscher, Karl, Saba, Rami, Baumgartner, Christian, Baumgarten, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6125370/
https://www.ncbi.nlm.nih.gov/pubmed/30214391
http://dx.doi.org/10.3389/fnins.2018.00588
_version_ 1783353150663557120
author Schier, Peter
Handler, Michael
Johnson Chacko, Lejo
Schrott-Fischer, Anneliese
Fritscher, Karl
Saba, Rami
Baumgartner, Christian
Baumgarten, Daniel
author_facet Schier, Peter
Handler, Michael
Johnson Chacko, Lejo
Schrott-Fischer, Anneliese
Fritscher, Karl
Saba, Rami
Baumgartner, Christian
Baumgarten, Daniel
author_sort Schier, Peter
collection PubMed
description A dysfunctional vestibular system can be a severe detriment to the quality of life of a patient. Recent studies have shown the feasibility for a vestibular implant to restore rotational sensation via electrical stimulation of vestibular ampullary nerves. However, the optimal stimulation site for selective elicitation of the desired nerve is still unknown. We realized a finite element model on the basis of μCT scans of a human inner ear and incorporated naturally distributed, artificial neural trajectories. A well-validated neuron model of myelinated fibers was incorporated to predict nerve responses to electrical stimulation. Several virtual electrodes were placed in locations of interest inside the bony labyrinth (intra-labyrinthine) and inside the temporal bone, near the target nerves (extra-labyrinthine), to determine preferred stimulation sites and electrode insertion depths. We investigated various monopolar and bipolar electrode configurations as well as different pulse waveform shapes for their ability to selectively stimulate the target nerve and for their energy consumption. The selectivity was evaluated with an objective measure of the fiber recruitment. Considerable differences of required energy and achievable selectivity between the configurations were observed. Bipolar, intra-labyrinthine electrodes provided the best selectivities but also consumed the highest amount of energy. Bipolar, extra-labyrinthine configurations did not offer any advantages compared to the monopolar approach. No selective stimulation could be performed with the monopolar, intra-labyrinthine approach. The monopolar, extra-labyrinthine electrodes required the least energy for satisfactory selectivities, making it the most promising approach for functional vestibular implants. Different pulse waveform shapes did not affect the achieved selectivity considerably but shorter pulse durations showed consistently a more selective activation of the target nerves. A cathodic, centered triangular waveform shape was identified as the most energy-efficient of the tested shapes. Based on these simulations we are able to recommend the monopolar, extra-labyrinthine stimulation approach with cathodic, centered triangular pulses as good trade-off between selectivity and energy consumption. Future implant designs could benefit from the findings presented here.
format Online
Article
Text
id pubmed-6125370
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-61253702018-09-13 Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes Schier, Peter Handler, Michael Johnson Chacko, Lejo Schrott-Fischer, Anneliese Fritscher, Karl Saba, Rami Baumgartner, Christian Baumgarten, Daniel Front Neurosci Neuroscience A dysfunctional vestibular system can be a severe detriment to the quality of life of a patient. Recent studies have shown the feasibility for a vestibular implant to restore rotational sensation via electrical stimulation of vestibular ampullary nerves. However, the optimal stimulation site for selective elicitation of the desired nerve is still unknown. We realized a finite element model on the basis of μCT scans of a human inner ear and incorporated naturally distributed, artificial neural trajectories. A well-validated neuron model of myelinated fibers was incorporated to predict nerve responses to electrical stimulation. Several virtual electrodes were placed in locations of interest inside the bony labyrinth (intra-labyrinthine) and inside the temporal bone, near the target nerves (extra-labyrinthine), to determine preferred stimulation sites and electrode insertion depths. We investigated various monopolar and bipolar electrode configurations as well as different pulse waveform shapes for their ability to selectively stimulate the target nerve and for their energy consumption. The selectivity was evaluated with an objective measure of the fiber recruitment. Considerable differences of required energy and achievable selectivity between the configurations were observed. Bipolar, intra-labyrinthine electrodes provided the best selectivities but also consumed the highest amount of energy. Bipolar, extra-labyrinthine configurations did not offer any advantages compared to the monopolar approach. No selective stimulation could be performed with the monopolar, intra-labyrinthine approach. The monopolar, extra-labyrinthine electrodes required the least energy for satisfactory selectivities, making it the most promising approach for functional vestibular implants. Different pulse waveform shapes did not affect the achieved selectivity considerably but shorter pulse durations showed consistently a more selective activation of the target nerves. A cathodic, centered triangular waveform shape was identified as the most energy-efficient of the tested shapes. Based on these simulations we are able to recommend the monopolar, extra-labyrinthine stimulation approach with cathodic, centered triangular pulses as good trade-off between selectivity and energy consumption. Future implant designs could benefit from the findings presented here. Frontiers Media S.A. 2018-08-30 /pmc/articles/PMC6125370/ /pubmed/30214391 http://dx.doi.org/10.3389/fnins.2018.00588 Text en Copyright © 2018 Schier, Handler, Johnson Chacko, Schrott-Fischer, Fritscher, Saba, Baumgartner and Baumgarten. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Schier, Peter
Handler, Michael
Johnson Chacko, Lejo
Schrott-Fischer, Anneliese
Fritscher, Karl
Saba, Rami
Baumgartner, Christian
Baumgarten, Daniel
Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes
title Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes
title_full Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes
title_fullStr Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes
title_full_unstemmed Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes
title_short Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes
title_sort model-based vestibular afferent stimulation: evaluating selective electrode locations and stimulation waveform shapes
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6125370/
https://www.ncbi.nlm.nih.gov/pubmed/30214391
http://dx.doi.org/10.3389/fnins.2018.00588
work_keys_str_mv AT schierpeter modelbasedvestibularafferentstimulationevaluatingselectiveelectrodelocationsandstimulationwaveformshapes
AT handlermichael modelbasedvestibularafferentstimulationevaluatingselectiveelectrodelocationsandstimulationwaveformshapes
AT johnsonchackolejo modelbasedvestibularafferentstimulationevaluatingselectiveelectrodelocationsandstimulationwaveformshapes
AT schrottfischeranneliese modelbasedvestibularafferentstimulationevaluatingselectiveelectrodelocationsandstimulationwaveformshapes
AT fritscherkarl modelbasedvestibularafferentstimulationevaluatingselectiveelectrodelocationsandstimulationwaveformshapes
AT sabarami modelbasedvestibularafferentstimulationevaluatingselectiveelectrodelocationsandstimulationwaveformshapes
AT baumgartnerchristian modelbasedvestibularafferentstimulationevaluatingselectiveelectrodelocationsandstimulationwaveformshapes
AT baumgartendaniel modelbasedvestibularafferentstimulationevaluatingselectiveelectrodelocationsandstimulationwaveformshapes