Cargando…
Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance
Orthostatic lightheadedness in healthy young adults often leads to syncope in severe cases. One suggested underlying mechanism of orthostatic lightheadedness is a drop in transient blood pressure (BP); however, a decrease in BP does not always lead to a drop in cerebral blood flow (CBF) due to cereb...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6125591/ https://www.ncbi.nlm.nih.gov/pubmed/30185974 http://dx.doi.org/10.1038/s41598-018-31685-y |
_version_ | 1783353185196310528 |
---|---|
author | Kim, Jae-Myoung Choi, Jong-Kwan Choi, Mingyu Ji, Minsu Hwang, Gunpil Ko, Sang-Bae Bae, Hyeon-Min |
author_facet | Kim, Jae-Myoung Choi, Jong-Kwan Choi, Mingyu Ji, Minsu Hwang, Gunpil Ko, Sang-Bae Bae, Hyeon-Min |
author_sort | Kim, Jae-Myoung |
collection | PubMed |
description | Orthostatic lightheadedness in healthy young adults often leads to syncope in severe cases. One suggested underlying mechanism of orthostatic lightheadedness is a drop in transient blood pressure (BP); however, a decrease in BP does not always lead to a drop in cerebral blood flow (CBF) due to cerebral autoregulation (CA). We present a direct assessment method of CA using a multichannel continuous-wave near-infrared spectroscopy (CW-NIRS) device that measures the temporal changes in oxy- and deoxy-hemoglobin concentrations in the prefrontal cortex. Twenty healthy young adults were recruited. During the experiment, continuous beat-to-beat BP and heart rate were simultaneously measured during repetitive squat-stand maneuvers. We introduce a new metric termed ‘time-derivative hemodynamic model (DHbT)’, which is the time-derivative of total-hemoglobin concentration change that reflects the changes of cerebral blood volume and CBF. Although the absolute levels and the variations of systolic and diastolic BPs and mean arterial pressure showed no significant difference between the two groups, the proposed model showed a distinct difference in slope variation and response time of DHbT between the subjects with frequent symptom of orthostatic intolerance and the healthy control subjects. Thus, these results clearly demonstrate the feasibility of using CW-NIRS devices as a CA performance assessment tool. |
format | Online Article Text |
id | pubmed-6125591 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-61255912018-09-10 Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance Kim, Jae-Myoung Choi, Jong-Kwan Choi, Mingyu Ji, Minsu Hwang, Gunpil Ko, Sang-Bae Bae, Hyeon-Min Sci Rep Article Orthostatic lightheadedness in healthy young adults often leads to syncope in severe cases. One suggested underlying mechanism of orthostatic lightheadedness is a drop in transient blood pressure (BP); however, a decrease in BP does not always lead to a drop in cerebral blood flow (CBF) due to cerebral autoregulation (CA). We present a direct assessment method of CA using a multichannel continuous-wave near-infrared spectroscopy (CW-NIRS) device that measures the temporal changes in oxy- and deoxy-hemoglobin concentrations in the prefrontal cortex. Twenty healthy young adults were recruited. During the experiment, continuous beat-to-beat BP and heart rate were simultaneously measured during repetitive squat-stand maneuvers. We introduce a new metric termed ‘time-derivative hemodynamic model (DHbT)’, which is the time-derivative of total-hemoglobin concentration change that reflects the changes of cerebral blood volume and CBF. Although the absolute levels and the variations of systolic and diastolic BPs and mean arterial pressure showed no significant difference between the two groups, the proposed model showed a distinct difference in slope variation and response time of DHbT between the subjects with frequent symptom of orthostatic intolerance and the healthy control subjects. Thus, these results clearly demonstrate the feasibility of using CW-NIRS devices as a CA performance assessment tool. Nature Publishing Group UK 2018-09-05 /pmc/articles/PMC6125591/ /pubmed/30185974 http://dx.doi.org/10.1038/s41598-018-31685-y Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Kim, Jae-Myoung Choi, Jong-Kwan Choi, Mingyu Ji, Minsu Hwang, Gunpil Ko, Sang-Bae Bae, Hyeon-Min Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance |
title | Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance |
title_full | Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance |
title_fullStr | Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance |
title_full_unstemmed | Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance |
title_short | Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance |
title_sort | assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6125591/ https://www.ncbi.nlm.nih.gov/pubmed/30185974 http://dx.doi.org/10.1038/s41598-018-31685-y |
work_keys_str_mv | AT kimjaemyoung assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance AT choijongkwan assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance AT choimingyu assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance AT jiminsu assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance AT hwanggunpil assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance AT kosangbae assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance AT baehyeonmin assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance |