Cargando…

Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance

Orthostatic lightheadedness in healthy young adults often leads to syncope in severe cases. One suggested underlying mechanism of orthostatic lightheadedness is a drop in transient blood pressure (BP); however, a decrease in BP does not always lead to a drop in cerebral blood flow (CBF) due to cereb...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jae-Myoung, Choi, Jong-Kwan, Choi, Mingyu, Ji, Minsu, Hwang, Gunpil, Ko, Sang-Bae, Bae, Hyeon-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6125591/
https://www.ncbi.nlm.nih.gov/pubmed/30185974
http://dx.doi.org/10.1038/s41598-018-31685-y
_version_ 1783353185196310528
author Kim, Jae-Myoung
Choi, Jong-Kwan
Choi, Mingyu
Ji, Minsu
Hwang, Gunpil
Ko, Sang-Bae
Bae, Hyeon-Min
author_facet Kim, Jae-Myoung
Choi, Jong-Kwan
Choi, Mingyu
Ji, Minsu
Hwang, Gunpil
Ko, Sang-Bae
Bae, Hyeon-Min
author_sort Kim, Jae-Myoung
collection PubMed
description Orthostatic lightheadedness in healthy young adults often leads to syncope in severe cases. One suggested underlying mechanism of orthostatic lightheadedness is a drop in transient blood pressure (BP); however, a decrease in BP does not always lead to a drop in cerebral blood flow (CBF) due to cerebral autoregulation (CA). We present a direct assessment method of CA using a multichannel continuous-wave near-infrared spectroscopy (CW-NIRS) device that measures the temporal changes in oxy- and deoxy-hemoglobin concentrations in the prefrontal cortex. Twenty healthy young adults were recruited. During the experiment, continuous beat-to-beat BP and heart rate were simultaneously measured during repetitive squat-stand maneuvers. We introduce a new metric termed ‘time-derivative hemodynamic model (DHbT)’, which is the time-derivative of total-hemoglobin concentration change that reflects the changes of cerebral blood volume and CBF. Although the absolute levels and the variations of systolic and diastolic BPs and mean arterial pressure showed no significant difference between the two groups, the proposed model showed a distinct difference in slope variation and response time of DHbT between the subjects with frequent symptom of orthostatic intolerance and the healthy control subjects. Thus, these results clearly demonstrate the feasibility of using CW-NIRS devices as a CA performance assessment tool.
format Online
Article
Text
id pubmed-6125591
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-61255912018-09-10 Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance Kim, Jae-Myoung Choi, Jong-Kwan Choi, Mingyu Ji, Minsu Hwang, Gunpil Ko, Sang-Bae Bae, Hyeon-Min Sci Rep Article Orthostatic lightheadedness in healthy young adults often leads to syncope in severe cases. One suggested underlying mechanism of orthostatic lightheadedness is a drop in transient blood pressure (BP); however, a decrease in BP does not always lead to a drop in cerebral blood flow (CBF) due to cerebral autoregulation (CA). We present a direct assessment method of CA using a multichannel continuous-wave near-infrared spectroscopy (CW-NIRS) device that measures the temporal changes in oxy- and deoxy-hemoglobin concentrations in the prefrontal cortex. Twenty healthy young adults were recruited. During the experiment, continuous beat-to-beat BP and heart rate were simultaneously measured during repetitive squat-stand maneuvers. We introduce a new metric termed ‘time-derivative hemodynamic model (DHbT)’, which is the time-derivative of total-hemoglobin concentration change that reflects the changes of cerebral blood volume and CBF. Although the absolute levels and the variations of systolic and diastolic BPs and mean arterial pressure showed no significant difference between the two groups, the proposed model showed a distinct difference in slope variation and response time of DHbT between the subjects with frequent symptom of orthostatic intolerance and the healthy control subjects. Thus, these results clearly demonstrate the feasibility of using CW-NIRS devices as a CA performance assessment tool. Nature Publishing Group UK 2018-09-05 /pmc/articles/PMC6125591/ /pubmed/30185974 http://dx.doi.org/10.1038/s41598-018-31685-y Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Kim, Jae-Myoung
Choi, Jong-Kwan
Choi, Mingyu
Ji, Minsu
Hwang, Gunpil
Ko, Sang-Bae
Bae, Hyeon-Min
Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance
title Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance
title_full Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance
title_fullStr Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance
title_full_unstemmed Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance
title_short Assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance
title_sort assessment of cerebral autoregulation using continuous-wave near-infrared spectroscopy during squat-stand maneuvers in subjects with symptoms of orthostatic intolerance
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6125591/
https://www.ncbi.nlm.nih.gov/pubmed/30185974
http://dx.doi.org/10.1038/s41598-018-31685-y
work_keys_str_mv AT kimjaemyoung assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance
AT choijongkwan assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance
AT choimingyu assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance
AT jiminsu assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance
AT hwanggunpil assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance
AT kosangbae assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance
AT baehyeonmin assessmentofcerebralautoregulationusingcontinuouswavenearinfraredspectroscopyduringsquatstandmaneuversinsubjectswithsymptomsoforthostaticintolerance