Technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area
Electric production data of a grid-connected hybrid system are presented. The system consists of a photovoltaic generator, a wind micro-generator in the presence (HPWBS) or absence (HPWS) of an electric storage system. In such a system, the power generated by RES (renewable energy sources) is sent d...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6126399/ https://www.ncbi.nlm.nih.gov/pubmed/30197915 http://dx.doi.org/10.1016/j.dib.2018.08.083 |
_version_ | 1783353325859635200 |
---|---|
author | Baglivo, Cristina Mazzeo, Domenico Oliveti, Giuseppe Congedo, Paolo M. |
author_facet | Baglivo, Cristina Mazzeo, Domenico Oliveti, Giuseppe Congedo, Paolo M. |
author_sort | Baglivo, Cristina |
collection | PubMed |
description | Electric production data of a grid-connected hybrid system are presented. The system consists of a photovoltaic generator, a wind micro-generator in the presence (HPWBS) or absence (HPWS) of an electric storage system. In such a system, the power generated by RES (renewable energy sources) is sent directly to balance the load. A residential use has been analysed in warm climate. The analysis has been carried out by TRNSYS 17 (Transient System Simulation) software and the mathematical modelling and the energy balance of the system have been shown in Mazzeo et al. (2018). The annual energy performance has been evaluated, in terms of dimensionless balance of the generated energy and dimensionless balance of the energy required by the load, for 375 hybrid system configurations. These configurations were obtained by varying the photovoltaic power, the wind power and the battery storage capacity, considering different hourly average daily values of the load. |
format | Online Article Text |
id | pubmed-6126399 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-61263992018-09-07 Technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area Baglivo, Cristina Mazzeo, Domenico Oliveti, Giuseppe Congedo, Paolo M. Data Brief Design Electric production data of a grid-connected hybrid system are presented. The system consists of a photovoltaic generator, a wind micro-generator in the presence (HPWBS) or absence (HPWS) of an electric storage system. In such a system, the power generated by RES (renewable energy sources) is sent directly to balance the load. A residential use has been analysed in warm climate. The analysis has been carried out by TRNSYS 17 (Transient System Simulation) software and the mathematical modelling and the energy balance of the system have been shown in Mazzeo et al. (2018). The annual energy performance has been evaluated, in terms of dimensionless balance of the generated energy and dimensionless balance of the energy required by the load, for 375 hybrid system configurations. These configurations were obtained by varying the photovoltaic power, the wind power and the battery storage capacity, considering different hourly average daily values of the load. Elsevier 2018-08-30 /pmc/articles/PMC6126399/ /pubmed/30197915 http://dx.doi.org/10.1016/j.dib.2018.08.083 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Design Baglivo, Cristina Mazzeo, Domenico Oliveti, Giuseppe Congedo, Paolo M. Technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area |
title | Technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area |
title_full | Technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area |
title_fullStr | Technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area |
title_full_unstemmed | Technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area |
title_short | Technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area |
title_sort | technical data of a grid-connected photovoltaic/wind hybrid system with and without storage battery for residential buildings located in a warm area |
topic | Design |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6126399/ https://www.ncbi.nlm.nih.gov/pubmed/30197915 http://dx.doi.org/10.1016/j.dib.2018.08.083 |
work_keys_str_mv | AT baglivocristina technicaldataofagridconnectedphotovoltaicwindhybridsystemwithandwithoutstoragebatteryforresidentialbuildingslocatedinawarmarea AT mazzeodomenico technicaldataofagridconnectedphotovoltaicwindhybridsystemwithandwithoutstoragebatteryforresidentialbuildingslocatedinawarmarea AT olivetigiuseppe technicaldataofagridconnectedphotovoltaicwindhybridsystemwithandwithoutstoragebatteryforresidentialbuildingslocatedinawarmarea AT congedopaolom technicaldataofagridconnectedphotovoltaicwindhybridsystemwithandwithoutstoragebatteryforresidentialbuildingslocatedinawarmarea |