Cargando…
Proper Cut-off Levels of Serum Specific IgE to Cefaclor for Patients with Cefaclor Allergy
PURPOSE: Cefaclor, a second-generation oral cephalosporin, is known to cause IgE-mediated hypersensitivity. Assays of serum-specific IgE (sIgE) to cefaclor are commercially available via the ImmunoCAP system (Thermo Fisher Scientific). While serum levels of sIgE >0.35 kU/L are considered indicati...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6127431/ https://www.ncbi.nlm.nih.gov/pubmed/30187704 http://dx.doi.org/10.3349/ymj.2018.59.8.968 |
Sumario: | PURPOSE: Cefaclor, a second-generation oral cephalosporin, is known to cause IgE-mediated hypersensitivity. Assays of serum-specific IgE (sIgE) to cefaclor are commercially available via the ImmunoCAP system (Thermo Fisher Scientific). While serum levels of sIgE >0.35 kU/L are considered indicative of an allergy, some patients with cefaclor allergy show low serum IgE levels. This study aimed to evaluate the proper cut-off levels of sIgE in the diagnosis of immediate hypersensitivity to cefaclor. MATERIALS AND METHODS: A total of 269 patients with drug allergy history, who underwent assays of sIgE to cefaclor at Ajou University hospital and Dong-A University Hospital, were reviewed retrospectively. Among them, 193 patients exhibited cefaclor-induced immediate hypersensitivity with certain or probable causality of an adverse drug reaction according to the WHO-UMC (the World Health Organization-the Uppsala Monitoring Centre) algorithm, and 76 controls showed delayed hypersensitivity reactions to non-antibiotics. RESULTS: In total, 126 of the 193 patients (65.3%) experienced anaphylaxis; they had higher serum sIgE levels than patients with immediate hypersensitivity who did not experience anaphylaxis (6.36±12.39 kU/L vs. 4.28±13.61 kU/L, p<0.001). The best cut-off value for cefaclor-induced immediate hypersensitivity was 0.11 kU/L, with sensitivity of 80.2% and specificity of 81.6%. A cut-off value of 0.44 kU/L showed the best sensitivity (75.4%) and specificity (65.7%) for differentiating anaphylaxis from immediate hypersensitivity reactions. CONCLUSION: Patients with cefaclor anaphylaxis exhibit high serum IgE levels. A cut-off value of 0.11 kU/L of sIgE to cefaclor is proper for identifying patients with cefaclor allergy, and 0.44 kU/L may be useful to detect anaphylaxis. |
---|