Cargando…

Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples

A recently released kit (PerFix EXPOSE) was reported to improve the measurement of the degree of phosphorylation of proteins in leukocytes by flow cytometry. We tested its adaptation for platelets to monitor vasodilator-stimulated phosphoprotein (VASP) phosphorylation, which is the basis of a curren...

Descripción completa

Detalles Bibliográficos
Autores principales: Mallouk, N., Varvat, J., Berger, A., Epinat, M., Accassat, S., Garcin, A., Montmartin, A., Li, G., Garnier, P., Mismetti, P., Lambert, C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6128249/
https://www.ncbi.nlm.nih.gov/pubmed/30202779
http://dx.doi.org/10.1016/j.plabm.2018.02.002
_version_ 1783353616606691328
author Mallouk, N.
Varvat, J.
Berger, A.
Epinat, M.
Accassat, S.
Garcin, A.
Montmartin, A.
Li, G.
Garnier, P.
Mismetti, P.
Lambert, C.
author_facet Mallouk, N.
Varvat, J.
Berger, A.
Epinat, M.
Accassat, S.
Garcin, A.
Montmartin, A.
Li, G.
Garnier, P.
Mismetti, P.
Lambert, C.
author_sort Mallouk, N.
collection PubMed
description A recently released kit (PerFix EXPOSE) was reported to improve the measurement of the degree of phosphorylation of proteins in leukocytes by flow cytometry. We tested its adaptation for platelets to monitor vasodilator-stimulated phosphoprotein (VASP) phosphorylation, which is the basis of a currently used test for the assessment of the pharmacological response to P2Y12 antagonists (PLT VASP/P2Y12). The PerFix EXPOSE kit was compared to the PLT VASP/P2Y12 kit by using blood samples drawn at 24 h post clopidogrel dose from 19 patients hospitalized for a non-cardio-embolic ischemic stroke and treated with clopidogrel monotherapy for at least five days in an observational study. The platelet PerFix method was based on adaptation of the volume of the sample, the centrifugation speed and the incubation temperature. Poor agreement between prevention by adenosine diphosphate (ADP) of PGE(1)-induced cAMP-mediated VASP phosphorylation and ADP induced aggregation assessed by Light Transmittance Aggregometry was found. We found a significant correlation between the PLT VASP/P2Y12 kit and the PerFix EXPOSE kit. The PerFix EXPOSE kit may also be helpful to monitor adverse effects of second-generation tyrosine kinase inhibitors on platelets.
format Online
Article
Text
id pubmed-6128249
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-61282492018-09-10 Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples Mallouk, N. Varvat, J. Berger, A. Epinat, M. Accassat, S. Garcin, A. Montmartin, A. Li, G. Garnier, P. Mismetti, P. Lambert, C. Pract Lab Med Article A recently released kit (PerFix EXPOSE) was reported to improve the measurement of the degree of phosphorylation of proteins in leukocytes by flow cytometry. We tested its adaptation for platelets to monitor vasodilator-stimulated phosphoprotein (VASP) phosphorylation, which is the basis of a currently used test for the assessment of the pharmacological response to P2Y12 antagonists (PLT VASP/P2Y12). The PerFix EXPOSE kit was compared to the PLT VASP/P2Y12 kit by using blood samples drawn at 24 h post clopidogrel dose from 19 patients hospitalized for a non-cardio-embolic ischemic stroke and treated with clopidogrel monotherapy for at least five days in an observational study. The platelet PerFix method was based on adaptation of the volume of the sample, the centrifugation speed and the incubation temperature. Poor agreement between prevention by adenosine diphosphate (ADP) of PGE(1)-induced cAMP-mediated VASP phosphorylation and ADP induced aggregation assessed by Light Transmittance Aggregometry was found. We found a significant correlation between the PLT VASP/P2Y12 kit and the PerFix EXPOSE kit. The PerFix EXPOSE kit may also be helpful to monitor adverse effects of second-generation tyrosine kinase inhibitors on platelets. Elsevier 2018-02-16 /pmc/articles/PMC6128249/ /pubmed/30202779 http://dx.doi.org/10.1016/j.plabm.2018.02.002 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mallouk, N.
Varvat, J.
Berger, A.
Epinat, M.
Accassat, S.
Garcin, A.
Montmartin, A.
Li, G.
Garnier, P.
Mismetti, P.
Lambert, C.
Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples
title Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples
title_full Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples
title_fullStr Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples
title_full_unstemmed Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples
title_short Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples
title_sort assessment of a flow cytometry technique for studying signaling pathways in platelets: monitoring of vasp phosphorylation in clinical samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6128249/
https://www.ncbi.nlm.nih.gov/pubmed/30202779
http://dx.doi.org/10.1016/j.plabm.2018.02.002
work_keys_str_mv AT malloukn assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT varvatj assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT bergera assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT epinatm assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT accassats assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT garcina assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT montmartina assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT lig assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT garnierp assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT mismettip assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples
AT lambertc assessmentofaflowcytometrytechniqueforstudyingsignalingpathwaysinplateletsmonitoringofvaspphosphorylationinclinicalsamples