Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy

PURPOSE: To develop a 4D dose reconstruction method and to evaluate the delivered dose in respiratory-gated volumetric modulated arc therapy (VMAT). MATERIALS AND METHODS: A total 112 treatment sessions of gated VMAT for 30 stereotactic body radiotherapy (SBRT) patients (10 lung, 10 liver, and 10 pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Chung, Hyekyun, Jung, Jinhong, Jeong, Chiyoung, Kwak, Jungwon, Park, Jin-hong, Kim, Su Ssan, Yoon, Sang Min, Song, Si Yeol, Kim, Jong Hoon, Choi, Eun Kyung, Cho, Seungryong, Cho, Byungchul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6128520/
https://www.ncbi.nlm.nih.gov/pubmed/30192793
http://dx.doi.org/10.1371/journal.pone.0202765
_version_ 1783353655116693504
author Chung, Hyekyun
Jung, Jinhong
Jeong, Chiyoung
Kwak, Jungwon
Park, Jin-hong
Kim, Su Ssan
Yoon, Sang Min
Song, Si Yeol
Kim, Jong Hoon
Choi, Eun Kyung
Cho, Seungryong
Cho, Byungchul
author_facet Chung, Hyekyun
Jung, Jinhong
Jeong, Chiyoung
Kwak, Jungwon
Park, Jin-hong
Kim, Su Ssan
Yoon, Sang Min
Song, Si Yeol
Kim, Jong Hoon
Choi, Eun Kyung
Cho, Seungryong
Cho, Byungchul
author_sort Chung, Hyekyun
collection PubMed
description PURPOSE: To develop a 4D dose reconstruction method and to evaluate the delivered dose in respiratory-gated volumetric modulated arc therapy (VMAT). MATERIALS AND METHODS: A total 112 treatment sessions of gated VMAT for 30 stereotactic body radiotherapy (SBRT) patients (10 lung, 10 liver, and 10 pancreas) were evaluated. For respiratory-gated SBRT, 4DCT was acquired, and the CT data at the end-exhale phase was used for a VMAT plan. The delivered dose was reconstructed using a patient’s respiratory motion and machine motion acquired during the beam delivery. The machine motion was obtained from the treatment log file, while the target position was estimated from an external respiratory marker position. The target position was divided into 1-mm position bins, and sub-beams with beam isocenters corresponding to each position bin were created in a motion mimicking plan, reflecting motion data including MLC leaf positions and gantry angle and target position data during beam treatment. The reconstructed 4D dose was compared with the dose of the original plan using these dosimetric parameters; the maximum dose (D(max)) and mean dose (D(mean)) of gross target volume (GTV) or organs at risk (spinal cord, esophagus, heart, duodenum, kidney, spinal cord, and stomach). The minimum dose (D(min)) to GTV was also calculated to verify cold spots in tumors. RESULTS: There was no significant difference of dose parameters regard to the GTV in all tumors. For the liver cases, there were significant differences in the D(max) of duodenum (-4.2 ± 1.4%), stomach (-3.5 ± 4.2%), left kidney (-4.1 ± 2.8%), and right kidney (-3.2 ± 1.3%), and in the D(mean) of duodenum (-3.8 ± 1.4%), stomach (-3.9 ± 2.2%), left kidney (-3.1 ± 2.8%), and right kidney (-4.1 ± 2.6%). For the pancreas cases, there were significant differences in the D(max) of stomach (2.1 ± 3.0%), and in the D(mean) of liver (1.5 ± 0.6%), duodenum (-1.0 ± 1.4%), stomach (2.1 ± 1.6%), and right kidney (-1.3 ± 0.9%). The average gamma pass rates were 97.6 ± 4.8% for lung cases, 99.6 ± 0.5% for liver cases, and 99.5 ± 0.5% for pancreas cases. Most cases showed insignificant dose variation, with gamma pass rates higher than 98%, except for two lung cases with gamma pass rates of 86.9% and 90.6%. The low gamma pass rates showed larger global motion ranges resulting from the baseline shift during beam delivery. CONCLUSION: The actual delivered dose in thoracic and abdominal VMAT under breathing motion was verified by 4D dose reconstruction using typical treatment equipment and software. The proposed method provides a verification method for the actual delivered dose and could be a dosimetric verification QA tool for radiation treatment under various respiratory management techniques.
format Online
Article
Text
id pubmed-6128520
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61285202018-09-15 Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy Chung, Hyekyun Jung, Jinhong Jeong, Chiyoung Kwak, Jungwon Park, Jin-hong Kim, Su Ssan Yoon, Sang Min Song, Si Yeol Kim, Jong Hoon Choi, Eun Kyung Cho, Seungryong Cho, Byungchul PLoS One Research Article PURPOSE: To develop a 4D dose reconstruction method and to evaluate the delivered dose in respiratory-gated volumetric modulated arc therapy (VMAT). MATERIALS AND METHODS: A total 112 treatment sessions of gated VMAT for 30 stereotactic body radiotherapy (SBRT) patients (10 lung, 10 liver, and 10 pancreas) were evaluated. For respiratory-gated SBRT, 4DCT was acquired, and the CT data at the end-exhale phase was used for a VMAT plan. The delivered dose was reconstructed using a patient’s respiratory motion and machine motion acquired during the beam delivery. The machine motion was obtained from the treatment log file, while the target position was estimated from an external respiratory marker position. The target position was divided into 1-mm position bins, and sub-beams with beam isocenters corresponding to each position bin were created in a motion mimicking plan, reflecting motion data including MLC leaf positions and gantry angle and target position data during beam treatment. The reconstructed 4D dose was compared with the dose of the original plan using these dosimetric parameters; the maximum dose (D(max)) and mean dose (D(mean)) of gross target volume (GTV) or organs at risk (spinal cord, esophagus, heart, duodenum, kidney, spinal cord, and stomach). The minimum dose (D(min)) to GTV was also calculated to verify cold spots in tumors. RESULTS: There was no significant difference of dose parameters regard to the GTV in all tumors. For the liver cases, there were significant differences in the D(max) of duodenum (-4.2 ± 1.4%), stomach (-3.5 ± 4.2%), left kidney (-4.1 ± 2.8%), and right kidney (-3.2 ± 1.3%), and in the D(mean) of duodenum (-3.8 ± 1.4%), stomach (-3.9 ± 2.2%), left kidney (-3.1 ± 2.8%), and right kidney (-4.1 ± 2.6%). For the pancreas cases, there were significant differences in the D(max) of stomach (2.1 ± 3.0%), and in the D(mean) of liver (1.5 ± 0.6%), duodenum (-1.0 ± 1.4%), stomach (2.1 ± 1.6%), and right kidney (-1.3 ± 0.9%). The average gamma pass rates were 97.6 ± 4.8% for lung cases, 99.6 ± 0.5% for liver cases, and 99.5 ± 0.5% for pancreas cases. Most cases showed insignificant dose variation, with gamma pass rates higher than 98%, except for two lung cases with gamma pass rates of 86.9% and 90.6%. The low gamma pass rates showed larger global motion ranges resulting from the baseline shift during beam delivery. CONCLUSION: The actual delivered dose in thoracic and abdominal VMAT under breathing motion was verified by 4D dose reconstruction using typical treatment equipment and software. The proposed method provides a verification method for the actual delivered dose and could be a dosimetric verification QA tool for radiation treatment under various respiratory management techniques. Public Library of Science 2018-09-07 /pmc/articles/PMC6128520/ /pubmed/30192793 http://dx.doi.org/10.1371/journal.pone.0202765 Text en © 2018 Chung et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Chung, Hyekyun
Jung, Jinhong
Jeong, Chiyoung
Kwak, Jungwon
Park, Jin-hong
Kim, Su Ssan
Yoon, Sang Min
Song, Si Yeol
Kim, Jong Hoon
Choi, Eun Kyung
Cho, Seungryong
Cho, Byungchul
Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy
title Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy
title_full Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy
title_fullStr Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy
title_full_unstemmed Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy
title_short Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy
title_sort evaluation of delivered dose to a moving target by 4d dose reconstruction in gated volumetric modulated arc therapy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6128520/
https://www.ncbi.nlm.nih.gov/pubmed/30192793
http://dx.doi.org/10.1371/journal.pone.0202765
work_keys_str_mv AT chunghyekyun evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT jungjinhong evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT jeongchiyoung evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT kwakjungwon evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT parkjinhong evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT kimsussan evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT yoonsangmin evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT songsiyeol evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT kimjonghoon evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT choieunkyung evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT choseungryong evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy
AT chobyungchul evaluationofdelivereddosetoamovingtargetby4ddosereconstructioningatedvolumetricmodulatedarctherapy