Comparison of Lichtenstein Repair and Mesh Plug Repair Methods in The Treatment of Indirect Inguinal Hernia
Objective: The lifetime risk to develop an inguinal hernia is 27%-43% for men and 3%-6% for women. Methods of hernia repair currently involve prosthetic mesh applications. The aim of this study is to compare the Lichtenstein repair and Mesh-plug repair methods in the surgical treatment of indirect i...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6128592/ https://www.ncbi.nlm.nih.gov/pubmed/30202667 http://dx.doi.org/10.7759/cureus.2935 |
_version_ | 1783353671221772288 |
---|---|
author | Destek, Sebahattin Gul, Vahit Onur |
author_facet | Destek, Sebahattin Gul, Vahit Onur |
author_sort | Destek, Sebahattin |
collection | PubMed |
description | Objective: The lifetime risk to develop an inguinal hernia is 27%-43% for men and 3%-6% for women. Methods of hernia repair currently involve prosthetic mesh applications. The aim of this study is to compare the Lichtenstein repair and Mesh-plug repair methods in the surgical treatment of indirect inguinal hernias and to identify which of these two techniques is superior regarding its conferred advantages. Materials and Methods: In this study, a total of 102 patients who were diagnosed with indirect inguinal hernia between the years 2014 and 2015 without a previous operation were analyzed. Patients undergoing Lichtenstein repair and Mesh-plug repair were compared, especially during operation time, hospital stay, postoperative pain and other aspects. Results: The mean age of patients was 28.7 years (19-73). The mean duration of operations and hospitalizations was significantly shorter in patients who had undergone mesh-plug repair. Inguinal pain in the operation area on postoperative day one, two weeks and six months was significantly less in patients who had undergone mesh-plug repair. Patients were followed-up for two years. Conclusion: We concluded that mesh-plug repair was superior to Lichtenstein repair regarding postoperative pain, quality of life of the patient, shorter duration of operation, and duration of hospital stay although the two methods were similar regarding both recurrence and complication rates. Considering this information, we suggest that mesh-plug repair can be used safely for the treatment of indirect inguinal hernias. |
format | Online Article Text |
id | pubmed-6128592 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-61285922018-09-10 Comparison of Lichtenstein Repair and Mesh Plug Repair Methods in The Treatment of Indirect Inguinal Hernia Destek, Sebahattin Gul, Vahit Onur Cureus General Surgery Objective: The lifetime risk to develop an inguinal hernia is 27%-43% for men and 3%-6% for women. Methods of hernia repair currently involve prosthetic mesh applications. The aim of this study is to compare the Lichtenstein repair and Mesh-plug repair methods in the surgical treatment of indirect inguinal hernias and to identify which of these two techniques is superior regarding its conferred advantages. Materials and Methods: In this study, a total of 102 patients who were diagnosed with indirect inguinal hernia between the years 2014 and 2015 without a previous operation were analyzed. Patients undergoing Lichtenstein repair and Mesh-plug repair were compared, especially during operation time, hospital stay, postoperative pain and other aspects. Results: The mean age of patients was 28.7 years (19-73). The mean duration of operations and hospitalizations was significantly shorter in patients who had undergone mesh-plug repair. Inguinal pain in the operation area on postoperative day one, two weeks and six months was significantly less in patients who had undergone mesh-plug repair. Patients were followed-up for two years. Conclusion: We concluded that mesh-plug repair was superior to Lichtenstein repair regarding postoperative pain, quality of life of the patient, shorter duration of operation, and duration of hospital stay although the two methods were similar regarding both recurrence and complication rates. Considering this information, we suggest that mesh-plug repair can be used safely for the treatment of indirect inguinal hernias. Cureus 2018-07-06 /pmc/articles/PMC6128592/ /pubmed/30202667 http://dx.doi.org/10.7759/cureus.2935 Text en Copyright © 2018, Destek et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | General Surgery Destek, Sebahattin Gul, Vahit Onur Comparison of Lichtenstein Repair and Mesh Plug Repair Methods in The Treatment of Indirect Inguinal Hernia |
title | Comparison of Lichtenstein Repair and Mesh Plug Repair Methods in The Treatment of Indirect Inguinal Hernia |
title_full | Comparison of Lichtenstein Repair and Mesh Plug Repair Methods in The Treatment of Indirect Inguinal Hernia |
title_fullStr | Comparison of Lichtenstein Repair and Mesh Plug Repair Methods in The Treatment of Indirect Inguinal Hernia |
title_full_unstemmed | Comparison of Lichtenstein Repair and Mesh Plug Repair Methods in The Treatment of Indirect Inguinal Hernia |
title_short | Comparison of Lichtenstein Repair and Mesh Plug Repair Methods in The Treatment of Indirect Inguinal Hernia |
title_sort | comparison of lichtenstein repair and mesh plug repair methods in the treatment of indirect inguinal hernia |
topic | General Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6128592/ https://www.ncbi.nlm.nih.gov/pubmed/30202667 http://dx.doi.org/10.7759/cureus.2935 |
work_keys_str_mv | AT desteksebahattin comparisonoflichtensteinrepairandmeshplugrepairmethodsinthetreatmentofindirectinguinalhernia AT gulvahitonur comparisonoflichtensteinrepairandmeshplugrepairmethodsinthetreatmentofindirectinguinalhernia |