Cargando…

A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise

OBJECTIVES: The standard, monopolar (MP) electrode configuration used in commercially available cochlear implants (CI) creates a broad electrical field, which can lead to unwanted channel interactions. Use of more focused configurations, such as tripolar and phased array, has led to mixed results fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Arenberg, Julie G., Parkinson, Wendy S., Litvak, Leonid, Chen, Chen, Kreft, Heather A., Oxenham, Andrew J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Williams And Wilkins 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6129442/
https://www.ncbi.nlm.nih.gov/pubmed/29529006
http://dx.doi.org/10.1097/AUD.0000000000000566
_version_ 1783353796875780096
author Arenberg, Julie G.
Parkinson, Wendy S.
Litvak, Leonid
Chen, Chen
Kreft, Heather A.
Oxenham, Andrew J.
author_facet Arenberg, Julie G.
Parkinson, Wendy S.
Litvak, Leonid
Chen, Chen
Kreft, Heather A.
Oxenham, Andrew J.
author_sort Arenberg, Julie G.
collection PubMed
description OBJECTIVES: The standard, monopolar (MP) electrode configuration used in commercially available cochlear implants (CI) creates a broad electrical field, which can lead to unwanted channel interactions. Use of more focused configurations, such as tripolar and phased array, has led to mixed results for improving speech understanding. The purpose of the present study was to assess the efficacy of a physiologically inspired configuration called dynamic focusing, using focused tripolar stimulation at low levels and less focused stimulation at high levels. Dynamic focusing may better mimic cochlear excitation patterns in normal acoustic hearing, while reducing the current levels necessary to achieve sufficient loudness at high levels. DESIGN: Twenty postlingually deafened adult CI users participated in the study. Speech perception was assessed in quiet and in a four-talker babble background noise. Speech stimuli were closed-set spondees in noise, and medial vowels at 50 and 60 dB SPL in quiet and in noise. The signal to noise ratio was adjusted individually such that performance was between 40 and 60% correct with the MP strategy. Subjects were fitted with three experimental strategies matched for pulse duration, pulse rate, filter settings, and loudness on a channel-by-channel basis. The strategies included 14 channels programmed in MP, fixed partial tripolar (σ = 0.8), and dynamic partial tripolar (σ at 0.8 at threshold and 0.5 at the most comfortable level). Fifteen minutes of listening experience was provided with each strategy before testing. Sound quality ratings were also obtained. RESULTS: Speech perception performance for vowel identification in quiet at 50 and 60 dB SPL and for spondees in noise was similar for the three tested strategies. However, performance on vowel identification in noise was significantly better for listeners using the dynamic focusing strategy. Sound quality ratings were similar for the three strategies. Some subjects obtained more benefit than others, with some individual differences explained by the relation between loudness growth and the rate of change from focused to broader stimulation. CONCLUSIONS: These initial results suggest that further exploration of dynamic focusing is warranted. Specifically, optimizing such strategies on an individual basis may lead to improvements in speech perception for more adult listeners and improve how CIs are tailored. Some listeners may also need a longer period of time to acclimate to a new program.
format Online
Article
Text
id pubmed-6129442
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Williams And Wilkins
record_format MEDLINE/PubMed
spelling pubmed-61294422019-11-01 A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise Arenberg, Julie G. Parkinson, Wendy S. Litvak, Leonid Chen, Chen Kreft, Heather A. Oxenham, Andrew J. Ear Hear Research Articles OBJECTIVES: The standard, monopolar (MP) electrode configuration used in commercially available cochlear implants (CI) creates a broad electrical field, which can lead to unwanted channel interactions. Use of more focused configurations, such as tripolar and phased array, has led to mixed results for improving speech understanding. The purpose of the present study was to assess the efficacy of a physiologically inspired configuration called dynamic focusing, using focused tripolar stimulation at low levels and less focused stimulation at high levels. Dynamic focusing may better mimic cochlear excitation patterns in normal acoustic hearing, while reducing the current levels necessary to achieve sufficient loudness at high levels. DESIGN: Twenty postlingually deafened adult CI users participated in the study. Speech perception was assessed in quiet and in a four-talker babble background noise. Speech stimuli were closed-set spondees in noise, and medial vowels at 50 and 60 dB SPL in quiet and in noise. The signal to noise ratio was adjusted individually such that performance was between 40 and 60% correct with the MP strategy. Subjects were fitted with three experimental strategies matched for pulse duration, pulse rate, filter settings, and loudness on a channel-by-channel basis. The strategies included 14 channels programmed in MP, fixed partial tripolar (σ = 0.8), and dynamic partial tripolar (σ at 0.8 at threshold and 0.5 at the most comfortable level). Fifteen minutes of listening experience was provided with each strategy before testing. Sound quality ratings were also obtained. RESULTS: Speech perception performance for vowel identification in quiet at 50 and 60 dB SPL and for spondees in noise was similar for the three tested strategies. However, performance on vowel identification in noise was significantly better for listeners using the dynamic focusing strategy. Sound quality ratings were similar for the three strategies. Some subjects obtained more benefit than others, with some individual differences explained by the relation between loudness growth and the rate of change from focused to broader stimulation. CONCLUSIONS: These initial results suggest that further exploration of dynamic focusing is warranted. Specifically, optimizing such strategies on an individual basis may lead to improvements in speech perception for more adult listeners and improve how CIs are tailored. Some listeners may also need a longer period of time to acclimate to a new program. Williams And Wilkins 2018 2018-10-26 /pmc/articles/PMC6129442/ /pubmed/29529006 http://dx.doi.org/10.1097/AUD.0000000000000566 Text en Copyright © 2018 The Authors. Ear & Hearing is published on behalf of the American Auditory Society, by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Research Articles
Arenberg, Julie G.
Parkinson, Wendy S.
Litvak, Leonid
Chen, Chen
Kreft, Heather A.
Oxenham, Andrew J.
A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise
title A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise
title_full A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise
title_fullStr A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise
title_full_unstemmed A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise
title_short A Dynamically Focusing Cochlear Implant Strategy Can Improve Vowel Identification in Noise
title_sort dynamically focusing cochlear implant strategy can improve vowel identification in noise
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6129442/
https://www.ncbi.nlm.nih.gov/pubmed/29529006
http://dx.doi.org/10.1097/AUD.0000000000000566
work_keys_str_mv AT arenbergjulieg adynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT parkinsonwendys adynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT litvakleonid adynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT chenchen adynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT kreftheathera adynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT oxenhamandrewj adynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT arenbergjulieg dynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT parkinsonwendys dynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT litvakleonid dynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT chenchen dynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT kreftheathera dynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise
AT oxenhamandrewj dynamicallyfocusingcochlearimplantstrategycanimprovevowelidentificationinnoise