Cargando…

Euthanasia of laboratory mice: Are isoflurane and sevoflurane real alternatives to carbon dioxide?

In the European Union (EU) millions of laboratory mice are used and killed for experimental and other scientific purposes each year. Although controversially discussed, the use of carbon dioxide (CO(2)) is still permitted for killing rodents according to the Directive 2010/63/EU. Within the scope of...

Descripción completa

Detalles Bibliográficos
Autores principales: Marquardt, Nicole, Feja, Malte, Hünigen, Hana, Plendl, Johanna, Menken, Lena, Fink, Heidrun, Bert, Bettina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6130864/
https://www.ncbi.nlm.nih.gov/pubmed/30199551
http://dx.doi.org/10.1371/journal.pone.0203793
_version_ 1783354020858953728
author Marquardt, Nicole
Feja, Malte
Hünigen, Hana
Plendl, Johanna
Menken, Lena
Fink, Heidrun
Bert, Bettina
author_facet Marquardt, Nicole
Feja, Malte
Hünigen, Hana
Plendl, Johanna
Menken, Lena
Fink, Heidrun
Bert, Bettina
author_sort Marquardt, Nicole
collection PubMed
description In the European Union (EU) millions of laboratory mice are used and killed for experimental and other scientific purposes each year. Although controversially discussed, the use of carbon dioxide (CO(2)) is still permitted for killing rodents according to the Directive 2010/63/EU. Within the scope of refinement, our aim was to investigate if isoflurane and sevoflurane are an appropriate alternative killing method to CO(2) in mice. Different concentrations of CO(2) (filling rates of 20%, 60%, 100%; CO(2) 20, 60, 100), isoflurane (Iso 2%, 5%) and sevoflurane (Sevo 4.8%, 8%) were compared in two mouse strains (NMRI, C57Bl/6J) using a broad spectrum of behavioral parameters, including the approach-avoidance test, and analyzing blood for stress parameters (glucose, adrenaline, noradrenaline). We focused in our study on the period from the beginning of the gas inlet to loss of consciousness, as during this period animals are able to perceive pain and distress. Our results show that only higher concentrations of CO(2) (CO(2) 60, 100) and isoflurane (5%) induced surgical tolerance within 300 s in both strains, with CO(2) 100 being the fastest acting inhalant anesthetic. The potency of halogenated ethers depended on the mouse strain, with C57Bl/6J being more susceptible than NMRI mice. Behavioral analysis revealed no specific signs of distress, e. g. stress-induced grooming, and pain, i. e. audible vocalizations, for all inhalant gases. However, adrenaline and noradrenaline plasma concentrations were increased, especially in NMRI mice exposed to CO(2) in high concentrations, whereas we did not observe such increase in animals exposed to isoflurane or sevoflurane. Escape latencies in the approach-avoidance test using C57Bl/6J mice did not differ between the three inhalant gases, however, some animals became recumbent during isoflurane and sevoflurane but not during CO(2) exposure. The rise in catecholamine concentrations suggests that CO(2) exposure might be linked to a higher stress response compared to isoflurane and sevoflurane exposure, although we did not observe a behavioral correlate for that. Follow-up studies investigating other fast-acting stress hormones and central anxiety circuits are needed to confirm our findings.
format Online
Article
Text
id pubmed-6130864
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61308642018-09-15 Euthanasia of laboratory mice: Are isoflurane and sevoflurane real alternatives to carbon dioxide? Marquardt, Nicole Feja, Malte Hünigen, Hana Plendl, Johanna Menken, Lena Fink, Heidrun Bert, Bettina PLoS One Research Article In the European Union (EU) millions of laboratory mice are used and killed for experimental and other scientific purposes each year. Although controversially discussed, the use of carbon dioxide (CO(2)) is still permitted for killing rodents according to the Directive 2010/63/EU. Within the scope of refinement, our aim was to investigate if isoflurane and sevoflurane are an appropriate alternative killing method to CO(2) in mice. Different concentrations of CO(2) (filling rates of 20%, 60%, 100%; CO(2) 20, 60, 100), isoflurane (Iso 2%, 5%) and sevoflurane (Sevo 4.8%, 8%) were compared in two mouse strains (NMRI, C57Bl/6J) using a broad spectrum of behavioral parameters, including the approach-avoidance test, and analyzing blood for stress parameters (glucose, adrenaline, noradrenaline). We focused in our study on the period from the beginning of the gas inlet to loss of consciousness, as during this period animals are able to perceive pain and distress. Our results show that only higher concentrations of CO(2) (CO(2) 60, 100) and isoflurane (5%) induced surgical tolerance within 300 s in both strains, with CO(2) 100 being the fastest acting inhalant anesthetic. The potency of halogenated ethers depended on the mouse strain, with C57Bl/6J being more susceptible than NMRI mice. Behavioral analysis revealed no specific signs of distress, e. g. stress-induced grooming, and pain, i. e. audible vocalizations, for all inhalant gases. However, adrenaline and noradrenaline plasma concentrations were increased, especially in NMRI mice exposed to CO(2) in high concentrations, whereas we did not observe such increase in animals exposed to isoflurane or sevoflurane. Escape latencies in the approach-avoidance test using C57Bl/6J mice did not differ between the three inhalant gases, however, some animals became recumbent during isoflurane and sevoflurane but not during CO(2) exposure. The rise in catecholamine concentrations suggests that CO(2) exposure might be linked to a higher stress response compared to isoflurane and sevoflurane exposure, although we did not observe a behavioral correlate for that. Follow-up studies investigating other fast-acting stress hormones and central anxiety circuits are needed to confirm our findings. Public Library of Science 2018-09-10 /pmc/articles/PMC6130864/ /pubmed/30199551 http://dx.doi.org/10.1371/journal.pone.0203793 Text en © 2018 Marquardt et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Marquardt, Nicole
Feja, Malte
Hünigen, Hana
Plendl, Johanna
Menken, Lena
Fink, Heidrun
Bert, Bettina
Euthanasia of laboratory mice: Are isoflurane and sevoflurane real alternatives to carbon dioxide?
title Euthanasia of laboratory mice: Are isoflurane and sevoflurane real alternatives to carbon dioxide?
title_full Euthanasia of laboratory mice: Are isoflurane and sevoflurane real alternatives to carbon dioxide?
title_fullStr Euthanasia of laboratory mice: Are isoflurane and sevoflurane real alternatives to carbon dioxide?
title_full_unstemmed Euthanasia of laboratory mice: Are isoflurane and sevoflurane real alternatives to carbon dioxide?
title_short Euthanasia of laboratory mice: Are isoflurane and sevoflurane real alternatives to carbon dioxide?
title_sort euthanasia of laboratory mice: are isoflurane and sevoflurane real alternatives to carbon dioxide?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6130864/
https://www.ncbi.nlm.nih.gov/pubmed/30199551
http://dx.doi.org/10.1371/journal.pone.0203793
work_keys_str_mv AT marquardtnicole euthanasiaoflaboratorymiceareisofluraneandsevofluranerealalternativestocarbondioxide
AT fejamalte euthanasiaoflaboratorymiceareisofluraneandsevofluranerealalternativestocarbondioxide
AT hunigenhana euthanasiaoflaboratorymiceareisofluraneandsevofluranerealalternativestocarbondioxide
AT plendljohanna euthanasiaoflaboratorymiceareisofluraneandsevofluranerealalternativestocarbondioxide
AT menkenlena euthanasiaoflaboratorymiceareisofluraneandsevofluranerealalternativestocarbondioxide
AT finkheidrun euthanasiaoflaboratorymiceareisofluraneandsevofluranerealalternativestocarbondioxide
AT bertbettina euthanasiaoflaboratorymiceareisofluraneandsevofluranerealalternativestocarbondioxide