When to incorporate point-of-care ultrasound (POCUS) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 POCUS-assisted simulation protocols

BACKGROUND: The purpose of this study was to determine the ideal timing for providers to perform point-of-care ultrasound (POCUS) with the least increase in workload. METHODS: We conducted a pilot crossover study to compare 2 POCUS-assisted evaluation protocols for acutely ill patients: sequential (...

Descripción completa

Detalles Bibliográficos
Autores principales: Bennett, Courtney E., Samavedam, Sandhya, Jayaprakash, Namita, Kogan, Alexander, Gajic, Ognjen, Sekiguchi, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6131841/
https://www.ncbi.nlm.nih.gov/pubmed/30200973
http://dx.doi.org/10.1186/s12947-018-0132-0
_version_ 1783354206596366336
author Bennett, Courtney E.
Samavedam, Sandhya
Jayaprakash, Namita
Kogan, Alexander
Gajic, Ognjen
Sekiguchi, Hiroshi
author_facet Bennett, Courtney E.
Samavedam, Sandhya
Jayaprakash, Namita
Kogan, Alexander
Gajic, Ognjen
Sekiguchi, Hiroshi
author_sort Bennett, Courtney E.
collection PubMed
description BACKGROUND: The purpose of this study was to determine the ideal timing for providers to perform point-of-care ultrasound (POCUS) with the least increase in workload. METHODS: We conducted a pilot crossover study to compare 2 POCUS-assisted evaluation protocols for acutely ill patients: sequential (physical examination followed by POCUS) vs parallel (POCUS at the time of physical examination). Participants were randomly assigned to 2 groups according to which POCUS-assisted protocol (sequential vs parallel) was used during simulated scenarios. Subsequently, the groups were crossed over to complete assessment by using the other POCUS-assisted protocol in the same patient scenarios. Providers’ workloads, measured with the National Aeronautics and Space Administration Task Load Index (NASA-TLX) and time to complete patient evaluation, were compared between the 2 protocols. RESULTS: Seven providers completed 14 assessments (7 sequential and 7 parallel). The median (IQR) total NASA-TLX score was 30 (30–50) in the sequential and 55 (50–65) in the parallel protocol (P = .03), which suggests a significantly lower workload in the sequential protocol. When individual components of the NASA-TLX score were evaluated, mental demand and frustration level were significantly lower in the sequential than in the parallel protocol (40 [IQR, 30–60] vs 50 [IQR, 40–70]; P = .03 and 25 [IQR, 20–35] vs 60 [IQR, 45–85]; P = .02, respectively). The time needed to complete the assessment was similar between the sequential and parallel protocols (8.7 [IQR, 6–9] minutes vs 10.1 [IQR, 7–11] minutes, respectively; P = .30). CONCLUSIONS: A sequential POCUS-assisted protocol posed less workload to POCUS operators than the parallel protocol.
format Online
Article
Text
id pubmed-6131841
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-61318412018-09-13 When to incorporate point-of-care ultrasound (POCUS) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 POCUS-assisted simulation protocols Bennett, Courtney E. Samavedam, Sandhya Jayaprakash, Namita Kogan, Alexander Gajic, Ognjen Sekiguchi, Hiroshi Cardiovasc Ultrasound Research BACKGROUND: The purpose of this study was to determine the ideal timing for providers to perform point-of-care ultrasound (POCUS) with the least increase in workload. METHODS: We conducted a pilot crossover study to compare 2 POCUS-assisted evaluation protocols for acutely ill patients: sequential (physical examination followed by POCUS) vs parallel (POCUS at the time of physical examination). Participants were randomly assigned to 2 groups according to which POCUS-assisted protocol (sequential vs parallel) was used during simulated scenarios. Subsequently, the groups were crossed over to complete assessment by using the other POCUS-assisted protocol in the same patient scenarios. Providers’ workloads, measured with the National Aeronautics and Space Administration Task Load Index (NASA-TLX) and time to complete patient evaluation, were compared between the 2 protocols. RESULTS: Seven providers completed 14 assessments (7 sequential and 7 parallel). The median (IQR) total NASA-TLX score was 30 (30–50) in the sequential and 55 (50–65) in the parallel protocol (P = .03), which suggests a significantly lower workload in the sequential protocol. When individual components of the NASA-TLX score were evaluated, mental demand and frustration level were significantly lower in the sequential than in the parallel protocol (40 [IQR, 30–60] vs 50 [IQR, 40–70]; P = .03 and 25 [IQR, 20–35] vs 60 [IQR, 45–85]; P = .02, respectively). The time needed to complete the assessment was similar between the sequential and parallel protocols (8.7 [IQR, 6–9] minutes vs 10.1 [IQR, 7–11] minutes, respectively; P = .30). CONCLUSIONS: A sequential POCUS-assisted protocol posed less workload to POCUS operators than the parallel protocol. BioMed Central 2018-09-11 /pmc/articles/PMC6131841/ /pubmed/30200973 http://dx.doi.org/10.1186/s12947-018-0132-0 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Bennett, Courtney E.
Samavedam, Sandhya
Jayaprakash, Namita
Kogan, Alexander
Gajic, Ognjen
Sekiguchi, Hiroshi
When to incorporate point-of-care ultrasound (POCUS) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 POCUS-assisted simulation protocols
title When to incorporate point-of-care ultrasound (POCUS) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 POCUS-assisted simulation protocols
title_full When to incorporate point-of-care ultrasound (POCUS) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 POCUS-assisted simulation protocols
title_fullStr When to incorporate point-of-care ultrasound (POCUS) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 POCUS-assisted simulation protocols
title_full_unstemmed When to incorporate point-of-care ultrasound (POCUS) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 POCUS-assisted simulation protocols
title_short When to incorporate point-of-care ultrasound (POCUS) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 POCUS-assisted simulation protocols
title_sort when to incorporate point-of-care ultrasound (pocus) into the initial assessment of acutely ill patients: a pilot crossover study to compare 2 pocus-assisted simulation protocols
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6131841/
https://www.ncbi.nlm.nih.gov/pubmed/30200973
http://dx.doi.org/10.1186/s12947-018-0132-0
work_keys_str_mv AT bennettcourtneye whentoincorporatepointofcareultrasoundpocusintotheinitialassessmentofacutelyillpatientsapilotcrossoverstudytocompare2pocusassistedsimulationprotocols
AT samavedamsandhya whentoincorporatepointofcareultrasoundpocusintotheinitialassessmentofacutelyillpatientsapilotcrossoverstudytocompare2pocusassistedsimulationprotocols
AT jayaprakashnamita whentoincorporatepointofcareultrasoundpocusintotheinitialassessmentofacutelyillpatientsapilotcrossoverstudytocompare2pocusassistedsimulationprotocols
AT koganalexander whentoincorporatepointofcareultrasoundpocusintotheinitialassessmentofacutelyillpatientsapilotcrossoverstudytocompare2pocusassistedsimulationprotocols
AT gajicognjen whentoincorporatepointofcareultrasoundpocusintotheinitialassessmentofacutelyillpatientsapilotcrossoverstudytocompare2pocusassistedsimulationprotocols
AT sekiguchihiroshi whentoincorporatepointofcareultrasoundpocusintotheinitialassessmentofacutelyillpatientsapilotcrossoverstudytocompare2pocusassistedsimulationprotocols