Cargando…

De-implementation of urodynamics in The Netherlands after the VALUE/VUSIS-2 results: a nationwide survey

INTRODUCTION AND HYPOTHESIS: We aimed to estimate the level of de-implementation of preoperative routine urodynamics (UDS) before stress urinary incontinence (SUI) surgery in The Netherlands and to analyze facilitators and barriers. Routine UDS was performed by 37% of the medical specialists in 2010...

Descripción completa

Detalles Bibliográficos
Autores principales: Mengerink, Bianca B., Nelen, Willianne L. D. M., van Leijsen, Sanne A. L., Heesakkers, John P. F. A., Kluivers, Kirsten B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer London 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6132705/
https://www.ncbi.nlm.nih.gov/pubmed/29679158
http://dx.doi.org/10.1007/s00192-018-3648-9
_version_ 1783354368981991424
author Mengerink, Bianca B.
Nelen, Willianne L. D. M.
van Leijsen, Sanne A. L.
Heesakkers, John P. F. A.
Kluivers, Kirsten B.
author_facet Mengerink, Bianca B.
Nelen, Willianne L. D. M.
van Leijsen, Sanne A. L.
Heesakkers, John P. F. A.
Kluivers, Kirsten B.
author_sort Mengerink, Bianca B.
collection PubMed
description INTRODUCTION AND HYPOTHESIS: We aimed to estimate the level of de-implementation of preoperative routine urodynamics (UDS) before stress urinary incontinence (SUI) surgery in The Netherlands and to analyze facilitators and barriers. Routine UDS was performed by 37% of the medical specialists in 2010. We hypothesized that the recommendations from the recent Value of Urodynamics prior to Stress Incontinence Surgery (VUSIS) and Value of Urodynamic Evaluation (ValUE) studies would have been followed by a reduction of routine UDS. METHODS: A national survey was performed among all Dutch gynecologists and urologists dealing with SUI in daily practice. The questionnaire contained two parts: (1) respondents’ characteristics and their actual care concerning preoperative UDS, and (2) facilitators and barriers. RESULTS: The response rate was 41% (127/308). Of the respondents, 93% (n = 118) did not perform routine UDS in the preoperative workup for women in this group. Professional characteristics associated with not following the recommendations were profession urologist, academic hospital, and a lower number of midurethral sling (MUS) placed yearly. Facilitators to follow the recommendation not to perform routine UDS were adequate design of the VUSIS-II study and outcome and recommendations from the studies. Barriers not to follow the recommendation were believe in the additional value of UDS, especially the pressure transmission ratio, and the presence of detrusor overactivity. CONCLUSION: According to respondents to this questionnaire, VUSIS-II and ValUE study results are well implemented in The Netherlands. The vast majority of respondents replied as not performing routine preoperative UDS in women with primary, uncomplicated (predominant) SUI. Therefore, there is no need for a further de-implementation strategy.
format Online
Article
Text
id pubmed-6132705
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer London
record_format MEDLINE/PubMed
spelling pubmed-61327052018-09-13 De-implementation of urodynamics in The Netherlands after the VALUE/VUSIS-2 results: a nationwide survey Mengerink, Bianca B. Nelen, Willianne L. D. M. van Leijsen, Sanne A. L. Heesakkers, John P. F. A. Kluivers, Kirsten B. Int Urogynecol J Original Article INTRODUCTION AND HYPOTHESIS: We aimed to estimate the level of de-implementation of preoperative routine urodynamics (UDS) before stress urinary incontinence (SUI) surgery in The Netherlands and to analyze facilitators and barriers. Routine UDS was performed by 37% of the medical specialists in 2010. We hypothesized that the recommendations from the recent Value of Urodynamics prior to Stress Incontinence Surgery (VUSIS) and Value of Urodynamic Evaluation (ValUE) studies would have been followed by a reduction of routine UDS. METHODS: A national survey was performed among all Dutch gynecologists and urologists dealing with SUI in daily practice. The questionnaire contained two parts: (1) respondents’ characteristics and their actual care concerning preoperative UDS, and (2) facilitators and barriers. RESULTS: The response rate was 41% (127/308). Of the respondents, 93% (n = 118) did not perform routine UDS in the preoperative workup for women in this group. Professional characteristics associated with not following the recommendations were profession urologist, academic hospital, and a lower number of midurethral sling (MUS) placed yearly. Facilitators to follow the recommendation not to perform routine UDS were adequate design of the VUSIS-II study and outcome and recommendations from the studies. Barriers not to follow the recommendation were believe in the additional value of UDS, especially the pressure transmission ratio, and the presence of detrusor overactivity. CONCLUSION: According to respondents to this questionnaire, VUSIS-II and ValUE study results are well implemented in The Netherlands. The vast majority of respondents replied as not performing routine preoperative UDS in women with primary, uncomplicated (predominant) SUI. Therefore, there is no need for a further de-implementation strategy. Springer London 2018-04-20 2018 /pmc/articles/PMC6132705/ /pubmed/29679158 http://dx.doi.org/10.1007/s00192-018-3648-9 Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Mengerink, Bianca B.
Nelen, Willianne L. D. M.
van Leijsen, Sanne A. L.
Heesakkers, John P. F. A.
Kluivers, Kirsten B.
De-implementation of urodynamics in The Netherlands after the VALUE/VUSIS-2 results: a nationwide survey
title De-implementation of urodynamics in The Netherlands after the VALUE/VUSIS-2 results: a nationwide survey
title_full De-implementation of urodynamics in The Netherlands after the VALUE/VUSIS-2 results: a nationwide survey
title_fullStr De-implementation of urodynamics in The Netherlands after the VALUE/VUSIS-2 results: a nationwide survey
title_full_unstemmed De-implementation of urodynamics in The Netherlands after the VALUE/VUSIS-2 results: a nationwide survey
title_short De-implementation of urodynamics in The Netherlands after the VALUE/VUSIS-2 results: a nationwide survey
title_sort de-implementation of urodynamics in the netherlands after the value/vusis-2 results: a nationwide survey
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6132705/
https://www.ncbi.nlm.nih.gov/pubmed/29679158
http://dx.doi.org/10.1007/s00192-018-3648-9
work_keys_str_mv AT mengerinkbiancab deimplementationofurodynamicsinthenetherlandsafterthevaluevusis2resultsanationwidesurvey
AT nelenwillianneldm deimplementationofurodynamicsinthenetherlandsafterthevaluevusis2resultsanationwidesurvey
AT vanleijsensanneal deimplementationofurodynamicsinthenetherlandsafterthevaluevusis2resultsanationwidesurvey
AT heesakkersjohnpfa deimplementationofurodynamicsinthenetherlandsafterthevaluevusis2resultsanationwidesurvey
AT kluiverskirstenb deimplementationofurodynamicsinthenetherlandsafterthevaluevusis2resultsanationwidesurvey