Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study

Based on three-dimensional scanning and computer-aided design and computer-aided manufacturing (CAD/CAM) techniques, customized bracket systems are increasingly used. However, data remain limited regarding customized bracket design, characteristics, and stability. This study was undertaken to evalua...

Descripción completa

Detalles Bibliográficos
Autores principales: Sha, Ha-Na, Choi, Sung-Hwan, Yu, Hyung-Seog, Hwang, Chung-Ju, Cha, Jung-Yul, Kim, Kwang-Mahn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6133347/
https://www.ncbi.nlm.nih.gov/pubmed/30204811
http://dx.doi.org/10.1371/journal.pone.0202952
_version_ 1783354490791919616
author Sha, Ha-Na
Choi, Sung-Hwan
Yu, Hyung-Seog
Hwang, Chung-Ju
Cha, Jung-Yul
Kim, Kwang-Mahn
author_facet Sha, Ha-Na
Choi, Sung-Hwan
Yu, Hyung-Seog
Hwang, Chung-Ju
Cha, Jung-Yul
Kim, Kwang-Mahn
author_sort Sha, Ha-Na
collection PubMed
description Based on three-dimensional scanning and computer-aided design and computer-aided manufacturing (CAD/CAM) techniques, customized bracket systems are increasingly used. However, data remain limited regarding customized bracket design, characteristics, and stability. This study was undertaken to evaluate the design, bond strength, and residual adhesives of four different CAD/CAM customized brackets that were attached to human tooth specimens by indirect bonding. Thirty extracted human upper premolars were divided into five groups: Group 1, preadjusted self-ligating labial metal bracket; Group 2, lingual self-ligating metal injection molding customized bracket; Group 3, gold-casted lingual customized bracket; Group 4, labial self-ligating milled customized bracket; Group 5, labial customized resin base bracket. Except in Group 1, premolar specimens were scanned via model scanner, and the images were sent to each manufacturing company to fabricate customized brackets and transfer trays/jigs. Debonding force (DF; N) was measured by Instron universal testing machine and shear bond strength (SBS; MPa) was calculated via dividing DF by bonding area. Adhesive remnants were analyzed via stereo microscopic images. Group 2 (196.90±82.75 N) exhibited significantly higher DF than Group 1 (62.77±12.65 N); other groups exhibited similar DFs, compared with Group 1. No customized bracket groups exhibited significant differences in SBS, relative to Group 1 (6.73±1.36 MPa). However, SBS in Group 5 (11.46±7.22 MPa) was significantly higher than in Group 3 (3.58±2.14 MPa). Group 3 had significantly lower ARI scores than other groups (P<0.05). Customized brackets exhibited large deviations in DF and SBS; all customized bracket systems exhibited DF that was equivalent or superior to that of preadjusted brackets, even when placed by indirect bonding.
format Online
Article
Text
id pubmed-6133347
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61333472018-09-27 Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study Sha, Ha-Na Choi, Sung-Hwan Yu, Hyung-Seog Hwang, Chung-Ju Cha, Jung-Yul Kim, Kwang-Mahn PLoS One Research Article Based on three-dimensional scanning and computer-aided design and computer-aided manufacturing (CAD/CAM) techniques, customized bracket systems are increasingly used. However, data remain limited regarding customized bracket design, characteristics, and stability. This study was undertaken to evaluate the design, bond strength, and residual adhesives of four different CAD/CAM customized brackets that were attached to human tooth specimens by indirect bonding. Thirty extracted human upper premolars were divided into five groups: Group 1, preadjusted self-ligating labial metal bracket; Group 2, lingual self-ligating metal injection molding customized bracket; Group 3, gold-casted lingual customized bracket; Group 4, labial self-ligating milled customized bracket; Group 5, labial customized resin base bracket. Except in Group 1, premolar specimens were scanned via model scanner, and the images were sent to each manufacturing company to fabricate customized brackets and transfer trays/jigs. Debonding force (DF; N) was measured by Instron universal testing machine and shear bond strength (SBS; MPa) was calculated via dividing DF by bonding area. Adhesive remnants were analyzed via stereo microscopic images. Group 2 (196.90±82.75 N) exhibited significantly higher DF than Group 1 (62.77±12.65 N); other groups exhibited similar DFs, compared with Group 1. No customized bracket groups exhibited significant differences in SBS, relative to Group 1 (6.73±1.36 MPa). However, SBS in Group 5 (11.46±7.22 MPa) was significantly higher than in Group 3 (3.58±2.14 MPa). Group 3 had significantly lower ARI scores than other groups (P<0.05). Customized brackets exhibited large deviations in DF and SBS; all customized bracket systems exhibited DF that was equivalent or superior to that of preadjusted brackets, even when placed by indirect bonding. Public Library of Science 2018-09-11 /pmc/articles/PMC6133347/ /pubmed/30204811 http://dx.doi.org/10.1371/journal.pone.0202952 Text en © 2018 Sha et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Sha, Ha-Na
Choi, Sung-Hwan
Yu, Hyung-Seog
Hwang, Chung-Ju
Cha, Jung-Yul
Kim, Kwang-Mahn
Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study
title Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study
title_full Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study
title_fullStr Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study
title_full_unstemmed Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study
title_short Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study
title_sort debonding force and shear bond strength of an array of cad/cam-based customized orthodontic brackets, placed by indirect bonding- an in vitro study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6133347/
https://www.ncbi.nlm.nih.gov/pubmed/30204811
http://dx.doi.org/10.1371/journal.pone.0202952
work_keys_str_mv AT shahana debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy
AT choisunghwan debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy
AT yuhyungseog debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy
AT hwangchungju debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy
AT chajungyul debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy
AT kimkwangmahn debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy