Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study
Based on three-dimensional scanning and computer-aided design and computer-aided manufacturing (CAD/CAM) techniques, customized bracket systems are increasingly used. However, data remain limited regarding customized bracket design, characteristics, and stability. This study was undertaken to evalua...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6133347/ https://www.ncbi.nlm.nih.gov/pubmed/30204811 http://dx.doi.org/10.1371/journal.pone.0202952 |
_version_ | 1783354490791919616 |
---|---|
author | Sha, Ha-Na Choi, Sung-Hwan Yu, Hyung-Seog Hwang, Chung-Ju Cha, Jung-Yul Kim, Kwang-Mahn |
author_facet | Sha, Ha-Na Choi, Sung-Hwan Yu, Hyung-Seog Hwang, Chung-Ju Cha, Jung-Yul Kim, Kwang-Mahn |
author_sort | Sha, Ha-Na |
collection | PubMed |
description | Based on three-dimensional scanning and computer-aided design and computer-aided manufacturing (CAD/CAM) techniques, customized bracket systems are increasingly used. However, data remain limited regarding customized bracket design, characteristics, and stability. This study was undertaken to evaluate the design, bond strength, and residual adhesives of four different CAD/CAM customized brackets that were attached to human tooth specimens by indirect bonding. Thirty extracted human upper premolars were divided into five groups: Group 1, preadjusted self-ligating labial metal bracket; Group 2, lingual self-ligating metal injection molding customized bracket; Group 3, gold-casted lingual customized bracket; Group 4, labial self-ligating milled customized bracket; Group 5, labial customized resin base bracket. Except in Group 1, premolar specimens were scanned via model scanner, and the images were sent to each manufacturing company to fabricate customized brackets and transfer trays/jigs. Debonding force (DF; N) was measured by Instron universal testing machine and shear bond strength (SBS; MPa) was calculated via dividing DF by bonding area. Adhesive remnants were analyzed via stereo microscopic images. Group 2 (196.90±82.75 N) exhibited significantly higher DF than Group 1 (62.77±12.65 N); other groups exhibited similar DFs, compared with Group 1. No customized bracket groups exhibited significant differences in SBS, relative to Group 1 (6.73±1.36 MPa). However, SBS in Group 5 (11.46±7.22 MPa) was significantly higher than in Group 3 (3.58±2.14 MPa). Group 3 had significantly lower ARI scores than other groups (P<0.05). Customized brackets exhibited large deviations in DF and SBS; all customized bracket systems exhibited DF that was equivalent or superior to that of preadjusted brackets, even when placed by indirect bonding. |
format | Online Article Text |
id | pubmed-6133347 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-61333472018-09-27 Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study Sha, Ha-Na Choi, Sung-Hwan Yu, Hyung-Seog Hwang, Chung-Ju Cha, Jung-Yul Kim, Kwang-Mahn PLoS One Research Article Based on three-dimensional scanning and computer-aided design and computer-aided manufacturing (CAD/CAM) techniques, customized bracket systems are increasingly used. However, data remain limited regarding customized bracket design, characteristics, and stability. This study was undertaken to evaluate the design, bond strength, and residual adhesives of four different CAD/CAM customized brackets that were attached to human tooth specimens by indirect bonding. Thirty extracted human upper premolars were divided into five groups: Group 1, preadjusted self-ligating labial metal bracket; Group 2, lingual self-ligating metal injection molding customized bracket; Group 3, gold-casted lingual customized bracket; Group 4, labial self-ligating milled customized bracket; Group 5, labial customized resin base bracket. Except in Group 1, premolar specimens were scanned via model scanner, and the images were sent to each manufacturing company to fabricate customized brackets and transfer trays/jigs. Debonding force (DF; N) was measured by Instron universal testing machine and shear bond strength (SBS; MPa) was calculated via dividing DF by bonding area. Adhesive remnants were analyzed via stereo microscopic images. Group 2 (196.90±82.75 N) exhibited significantly higher DF than Group 1 (62.77±12.65 N); other groups exhibited similar DFs, compared with Group 1. No customized bracket groups exhibited significant differences in SBS, relative to Group 1 (6.73±1.36 MPa). However, SBS in Group 5 (11.46±7.22 MPa) was significantly higher than in Group 3 (3.58±2.14 MPa). Group 3 had significantly lower ARI scores than other groups (P<0.05). Customized brackets exhibited large deviations in DF and SBS; all customized bracket systems exhibited DF that was equivalent or superior to that of preadjusted brackets, even when placed by indirect bonding. Public Library of Science 2018-09-11 /pmc/articles/PMC6133347/ /pubmed/30204811 http://dx.doi.org/10.1371/journal.pone.0202952 Text en © 2018 Sha et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Sha, Ha-Na Choi, Sung-Hwan Yu, Hyung-Seog Hwang, Chung-Ju Cha, Jung-Yul Kim, Kwang-Mahn Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study |
title | Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study |
title_full | Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study |
title_fullStr | Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study |
title_full_unstemmed | Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study |
title_short | Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study |
title_sort | debonding force and shear bond strength of an array of cad/cam-based customized orthodontic brackets, placed by indirect bonding- an in vitro study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6133347/ https://www.ncbi.nlm.nih.gov/pubmed/30204811 http://dx.doi.org/10.1371/journal.pone.0202952 |
work_keys_str_mv | AT shahana debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy AT choisunghwan debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy AT yuhyungseog debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy AT hwangchungju debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy AT chajungyul debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy AT kimkwangmahn debondingforceandshearbondstrengthofanarrayofcadcambasedcustomizedorthodonticbracketsplacedbyindirectbondinganinvitrostudy |