Cargando…

Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns

OBJECTIVES: To compare the diagnostic utility of electroencephalography (EEG) using reduced, 8-channel montage (rm-EEG) to full, 18-channel montage (fm-EEG) for detection of generalized or hemispheric seizures and rhythmic periodic patterns (RPPs) by neurologists with extensive EEG training, neurolo...

Descripción completa

Detalles Bibliográficos
Autores principales: Gururangan, Kapil, Razavi, Babak, Parvizi, Josef
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6133909/
https://www.ncbi.nlm.nih.gov/pubmed/30215011
http://dx.doi.org/10.1016/j.cnp.2018.03.001
_version_ 1783354568649736192
author Gururangan, Kapil
Razavi, Babak
Parvizi, Josef
author_facet Gururangan, Kapil
Razavi, Babak
Parvizi, Josef
author_sort Gururangan, Kapil
collection PubMed
description OBJECTIVES: To compare the diagnostic utility of electroencephalography (EEG) using reduced, 8-channel montage (rm-EEG) to full, 18-channel montage (fm-EEG) for detection of generalized or hemispheric seizures and rhythmic periodic patterns (RPPs) by neurologists with extensive EEG training, neurology residents with minimal EEG exposure, and medical students without EEG experience. METHODS: We presented EEG samples in both fm-EEG (bipolar montage) and rm-EEG (lateral leads of bipolar montage) to 20 neurologists, 20 residents, and 42 medical students. Unanimous agreement of three senior epileptologists defined samples as seizures (n = 7), RPPs (n = 10), and normal or slowing (n = 20). Differences in median accuracy, sensitivity, and specificity were assessed using Wilcoxon signed-rank tests. RESULTS: Full and reduced EEG demonstrated similar accuracy when read by neurologists (fm-EEG: 95%, rm-EEG: 95%, p = 0.29), residents (fm-EEG: 80%, rm-EEG: 80%, p = 0.05), and students (fm-EEG: 60%, rm-EEG: 51%, p = 0.68). Moreover, neurologists’ sensitivity for detecting seizure activity was comparable between fm-EEG (100%) and rm-EEG (98%) (p = 0.17). Furthermore, the specificity of rm-EEG for seizures and RPP (neurologists: 100%, residents: 90%, students: 86%) was significantly greater than that of fm-EEG (neurologists: 93%, p = 0.03; residents: 80%, p = 0.01; students: 69%, p < 0.001). CONCLUSIONS: The reduction of the number of EEG channels from 18 to 8 does not compromise neurologists’ sensitivity for detecting seizures that are often a core reason for performing urgent EEG. It may also increase their specificity for detecting rhythmic and periodic patterns, and thereby providing important diagnostic information to guide patient’s management. SIGNIFICANCE: Our study is the first to document the utility of a reduced channel EEG above the hairline compared to full montage EEG in aiding medical staff with varying degrees of EEG training to detect generalized or hemispheric seizures.
format Online
Article
Text
id pubmed-6133909
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-61339092018-09-13 Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns Gururangan, Kapil Razavi, Babak Parvizi, Josef Clin Neurophysiol Pract Clinical and Research Article OBJECTIVES: To compare the diagnostic utility of electroencephalography (EEG) using reduced, 8-channel montage (rm-EEG) to full, 18-channel montage (fm-EEG) for detection of generalized or hemispheric seizures and rhythmic periodic patterns (RPPs) by neurologists with extensive EEG training, neurology residents with minimal EEG exposure, and medical students without EEG experience. METHODS: We presented EEG samples in both fm-EEG (bipolar montage) and rm-EEG (lateral leads of bipolar montage) to 20 neurologists, 20 residents, and 42 medical students. Unanimous agreement of three senior epileptologists defined samples as seizures (n = 7), RPPs (n = 10), and normal or slowing (n = 20). Differences in median accuracy, sensitivity, and specificity were assessed using Wilcoxon signed-rank tests. RESULTS: Full and reduced EEG demonstrated similar accuracy when read by neurologists (fm-EEG: 95%, rm-EEG: 95%, p = 0.29), residents (fm-EEG: 80%, rm-EEG: 80%, p = 0.05), and students (fm-EEG: 60%, rm-EEG: 51%, p = 0.68). Moreover, neurologists’ sensitivity for detecting seizure activity was comparable between fm-EEG (100%) and rm-EEG (98%) (p = 0.17). Furthermore, the specificity of rm-EEG for seizures and RPP (neurologists: 100%, residents: 90%, students: 86%) was significantly greater than that of fm-EEG (neurologists: 93%, p = 0.03; residents: 80%, p = 0.01; students: 69%, p < 0.001). CONCLUSIONS: The reduction of the number of EEG channels from 18 to 8 does not compromise neurologists’ sensitivity for detecting seizures that are often a core reason for performing urgent EEG. It may also increase their specificity for detecting rhythmic and periodic patterns, and thereby providing important diagnostic information to guide patient’s management. SIGNIFICANCE: Our study is the first to document the utility of a reduced channel EEG above the hairline compared to full montage EEG in aiding medical staff with varying degrees of EEG training to detect generalized or hemispheric seizures. Elsevier 2018-03-26 /pmc/articles/PMC6133909/ /pubmed/30215011 http://dx.doi.org/10.1016/j.cnp.2018.03.001 Text en © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Clinical and Research Article
Gururangan, Kapil
Razavi, Babak
Parvizi, Josef
Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns
title Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns
title_full Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns
title_fullStr Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns
title_full_unstemmed Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns
title_short Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns
title_sort diagnostic utility of eight-channel eeg for detecting generalized or hemispheric seizures and rhythmic periodic patterns
topic Clinical and Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6133909/
https://www.ncbi.nlm.nih.gov/pubmed/30215011
http://dx.doi.org/10.1016/j.cnp.2018.03.001
work_keys_str_mv AT gururangankapil diagnosticutilityofeightchanneleegfordetectinggeneralizedorhemisphericseizuresandrhythmicperiodicpatterns
AT razavibabak diagnosticutilityofeightchanneleegfordetectinggeneralizedorhemisphericseizuresandrhythmicperiodicpatterns
AT parvizijosef diagnosticutilityofeightchanneleegfordetectinggeneralizedorhemisphericseizuresandrhythmicperiodicpatterns