Comparison of a Novel Cadaver Model (Fix for Life) With the Formalin-Fixed Cadaver and Manikin Model for Suitability and Realism in Airway Management Training

BACKGROUND: Manikins are widely used in airway management training; however, simulation of realism and interpatient variability remains a challenge. We investigated whether cadavers embalmed with the novel Fix for Life (F4L) embalmment method are a suitable and realistic model for teaching 3 basic a...

Descripción completa

Detalles Bibliográficos
Autores principales: van Emden, Michael W., Geurts, Jeroen J., Schober, Patrick, Schwarte, Lothar A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6135477/
https://www.ncbi.nlm.nih.gov/pubmed/30096080
http://dx.doi.org/10.1213/ANE.0000000000003678
_version_ 1783354832112844800
author van Emden, Michael W.
Geurts, Jeroen J.
Schober, Patrick
Schwarte, Lothar A.
author_facet van Emden, Michael W.
Geurts, Jeroen J.
Schober, Patrick
Schwarte, Lothar A.
author_sort van Emden, Michael W.
collection PubMed
description BACKGROUND: Manikins are widely used in airway management training; however, simulation of realism and interpatient variability remains a challenge. We investigated whether cadavers embalmed with the novel Fix for Life (F4L) embalmment method are a suitable and realistic model for teaching 3 basic airway skills: facemask ventilation, tracheal intubation, and laryngeal mask insertion compared to a manikin (SimMan 3G) and formalin-fixed cadavers. METHODS: Thirty anesthesiologists and experienced residents (“operators”) were instructed to perform the 3 airway techniques in 10 F4L, 10 formalin-fixed cadavers, and 1 manikin. The order of the model type was randomized per operator. Primary outcomes were the operators’ ranking of each model type as a teaching model (total rank), ranking of the model types per technique, and an operator’s average verbal rating score for suitability and realism of learning the technique on the model. Secondary outcomes were the percentages of successfully performed procedures per technique and per model (success rates in completing the respective airway maneuvers). For each of the airway techniques, the Friedman analysis of variance was used to compare the 3 models on mean operator ranking and mean verbal rating scores. RESULTS: Twenty-seven of 30 operators (90%) performed all airway techniques on all of the available models, whereas 3 operators performed the majority but not all of the airway maneuvers on all models for logistical reasons. The total number of attempts for each technique was 30 on the manikin, 292 in the F4L, and 282 on the formalin-fixed cadavers. The operators’ median total ranking of each model type as a teaching model was 1 for F4L, 2 for the manikin and, 3 for the formalin-fixed cadavers (P < .001). F4L was considered the best model for mask ventilation (P = .029) and had a higher mean verbal rating score for realism in laryngeal mask airway insertion (P = .043). The F4L and manikin did not differ significantly in other scores for suitability and realism. The formalin-fixed cadaver was ranked last and received lowest scores in all procedures (all P < .001). Success rates of the procedures were highest in the manikin. CONCLUSIONS: F4L cadavers were ranked highest for mask ventilation and were considered the most realistic model for training laryngeal mask insertion. Formalin-fixed cadavers are inappropriate for airway management training.
format Online
Article
Text
id pubmed-6135477
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-61354772018-09-20 Comparison of a Novel Cadaver Model (Fix for Life) With the Formalin-Fixed Cadaver and Manikin Model for Suitability and Realism in Airway Management Training van Emden, Michael W. Geurts, Jeroen J. Schober, Patrick Schwarte, Lothar A. Anesth Analg Trauma BACKGROUND: Manikins are widely used in airway management training; however, simulation of realism and interpatient variability remains a challenge. We investigated whether cadavers embalmed with the novel Fix for Life (F4L) embalmment method are a suitable and realistic model for teaching 3 basic airway skills: facemask ventilation, tracheal intubation, and laryngeal mask insertion compared to a manikin (SimMan 3G) and formalin-fixed cadavers. METHODS: Thirty anesthesiologists and experienced residents (“operators”) were instructed to perform the 3 airway techniques in 10 F4L, 10 formalin-fixed cadavers, and 1 manikin. The order of the model type was randomized per operator. Primary outcomes were the operators’ ranking of each model type as a teaching model (total rank), ranking of the model types per technique, and an operator’s average verbal rating score for suitability and realism of learning the technique on the model. Secondary outcomes were the percentages of successfully performed procedures per technique and per model (success rates in completing the respective airway maneuvers). For each of the airway techniques, the Friedman analysis of variance was used to compare the 3 models on mean operator ranking and mean verbal rating scores. RESULTS: Twenty-seven of 30 operators (90%) performed all airway techniques on all of the available models, whereas 3 operators performed the majority but not all of the airway maneuvers on all models for logistical reasons. The total number of attempts for each technique was 30 on the manikin, 292 in the F4L, and 282 on the formalin-fixed cadavers. The operators’ median total ranking of each model type as a teaching model was 1 for F4L, 2 for the manikin and, 3 for the formalin-fixed cadavers (P < .001). F4L was considered the best model for mask ventilation (P = .029) and had a higher mean verbal rating score for realism in laryngeal mask airway insertion (P = .043). The F4L and manikin did not differ significantly in other scores for suitability and realism. The formalin-fixed cadaver was ranked last and received lowest scores in all procedures (all P < .001). Success rates of the procedures were highest in the manikin. CONCLUSIONS: F4L cadavers were ranked highest for mask ventilation and were considered the most realistic model for training laryngeal mask insertion. Formalin-fixed cadavers are inappropriate for airway management training. Lippincott Williams & Wilkins 2018-10 2018-08-09 /pmc/articles/PMC6135477/ /pubmed/30096080 http://dx.doi.org/10.1213/ANE.0000000000003678 Text en Copyright © 2018 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the International Anesthesia Research Society. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Trauma
van Emden, Michael W.
Geurts, Jeroen J.
Schober, Patrick
Schwarte, Lothar A.
Comparison of a Novel Cadaver Model (Fix for Life) With the Formalin-Fixed Cadaver and Manikin Model for Suitability and Realism in Airway Management Training
title Comparison of a Novel Cadaver Model (Fix for Life) With the Formalin-Fixed Cadaver and Manikin Model for Suitability and Realism in Airway Management Training
title_full Comparison of a Novel Cadaver Model (Fix for Life) With the Formalin-Fixed Cadaver and Manikin Model for Suitability and Realism in Airway Management Training
title_fullStr Comparison of a Novel Cadaver Model (Fix for Life) With the Formalin-Fixed Cadaver and Manikin Model for Suitability and Realism in Airway Management Training
title_full_unstemmed Comparison of a Novel Cadaver Model (Fix for Life) With the Formalin-Fixed Cadaver and Manikin Model for Suitability and Realism in Airway Management Training
title_short Comparison of a Novel Cadaver Model (Fix for Life) With the Formalin-Fixed Cadaver and Manikin Model for Suitability and Realism in Airway Management Training
title_sort comparison of a novel cadaver model (fix for life) with the formalin-fixed cadaver and manikin model for suitability and realism in airway management training
topic Trauma
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6135477/
https://www.ncbi.nlm.nih.gov/pubmed/30096080
http://dx.doi.org/10.1213/ANE.0000000000003678
work_keys_str_mv AT vanemdenmichaelw comparisonofanovelcadavermodelfixforlifewiththeformalinfixedcadaverandmanikinmodelforsuitabilityandrealisminairwaymanagementtraining
AT geurtsjeroenj comparisonofanovelcadavermodelfixforlifewiththeformalinfixedcadaverandmanikinmodelforsuitabilityandrealisminairwaymanagementtraining
AT schoberpatrick comparisonofanovelcadavermodelfixforlifewiththeformalinfixedcadaverandmanikinmodelforsuitabilityandrealisminairwaymanagementtraining
AT schwartelothara comparisonofanovelcadavermodelfixforlifewiththeformalinfixedcadaverandmanikinmodelforsuitabilityandrealisminairwaymanagementtraining