Cargando…
Enabling tomography with low-cost C-arm systems
In scenarios where the use of a Computed Tomography (CT) is difficult, such as during surgery or in the ICU, the use of a C-arm system to generate tomographic information could contribute with interesting additional clinical information. Recent days are seeing the development of the so-called cone-b...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6136768/ https://www.ncbi.nlm.nih.gov/pubmed/30212543 http://dx.doi.org/10.1371/journal.pone.0203817 |
_version_ | 1783355066130890752 |
---|---|
author | Abella, Monica de Molina, Claudia Ballesteros, Nerea García-Santos, Alba Martínez, Álvaro García, Inés Desco, Manuel |
author_facet | Abella, Monica de Molina, Claudia Ballesteros, Nerea García-Santos, Alba Martínez, Álvaro García, Inés Desco, Manuel |
author_sort | Abella, Monica |
collection | PubMed |
description | In scenarios where the use of a Computed Tomography (CT) is difficult, such as during surgery or in the ICU, the use of a C-arm system to generate tomographic information could contribute with interesting additional clinical information. Recent days are seeing the development of the so-called cone-beam CT (CBCT) based on advanced motorized isocentric C-arm systems. To be able to make use of more basic C-arm systems, apart from the geometric non-idealities common to any CBCT, we need to address other difficulties. First, the trajectory of the source-detector pair may differ from a circular path and the system may suffer mechanical strains that modify the relative positions of the source and detector for different projection angles. Second, and more importantly, the exact position of the source and detector elements may not be repeatable for consecutive rotations due to low mechanical precision, thus preventing an accurate geometrical calibration of the system. Finally, the limitation of the angular span and the difficulty of obtaining a high number of projections pose a great challenge to the image reconstruction. In this work, we present a novel method to adapt a standard C-arm, originally designed for planar imaging, to be used as a tomograph. The key parts of the new acquisition protocol are (1) a geometrical calibration method to compensate mechanical inaccuracies that prevent an accurate repetition of source-detector position between acquisitions, and (2) an advanced image reconstruction method able to deal with limited angle data, sparse projections and non-circular trajectories. Both methods exploit surface information from the patient, which can be obtained using a 3D surface scanner. The proposed method was evaluated with two real C-arm systems, based on an image intensifier and a flat panel detector respectively, showing the feasibility of the proposal. |
format | Online Article Text |
id | pubmed-6136768 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-61367682018-09-27 Enabling tomography with low-cost C-arm systems Abella, Monica de Molina, Claudia Ballesteros, Nerea García-Santos, Alba Martínez, Álvaro García, Inés Desco, Manuel PLoS One Research Article In scenarios where the use of a Computed Tomography (CT) is difficult, such as during surgery or in the ICU, the use of a C-arm system to generate tomographic information could contribute with interesting additional clinical information. Recent days are seeing the development of the so-called cone-beam CT (CBCT) based on advanced motorized isocentric C-arm systems. To be able to make use of more basic C-arm systems, apart from the geometric non-idealities common to any CBCT, we need to address other difficulties. First, the trajectory of the source-detector pair may differ from a circular path and the system may suffer mechanical strains that modify the relative positions of the source and detector for different projection angles. Second, and more importantly, the exact position of the source and detector elements may not be repeatable for consecutive rotations due to low mechanical precision, thus preventing an accurate geometrical calibration of the system. Finally, the limitation of the angular span and the difficulty of obtaining a high number of projections pose a great challenge to the image reconstruction. In this work, we present a novel method to adapt a standard C-arm, originally designed for planar imaging, to be used as a tomograph. The key parts of the new acquisition protocol are (1) a geometrical calibration method to compensate mechanical inaccuracies that prevent an accurate repetition of source-detector position between acquisitions, and (2) an advanced image reconstruction method able to deal with limited angle data, sparse projections and non-circular trajectories. Both methods exploit surface information from the patient, which can be obtained using a 3D surface scanner. The proposed method was evaluated with two real C-arm systems, based on an image intensifier and a flat panel detector respectively, showing the feasibility of the proposal. Public Library of Science 2018-09-13 /pmc/articles/PMC6136768/ /pubmed/30212543 http://dx.doi.org/10.1371/journal.pone.0203817 Text en © 2018 Abella et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Abella, Monica de Molina, Claudia Ballesteros, Nerea García-Santos, Alba Martínez, Álvaro García, Inés Desco, Manuel Enabling tomography with low-cost C-arm systems |
title | Enabling tomography with low-cost C-arm systems |
title_full | Enabling tomography with low-cost C-arm systems |
title_fullStr | Enabling tomography with low-cost C-arm systems |
title_full_unstemmed | Enabling tomography with low-cost C-arm systems |
title_short | Enabling tomography with low-cost C-arm systems |
title_sort | enabling tomography with low-cost c-arm systems |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6136768/ https://www.ncbi.nlm.nih.gov/pubmed/30212543 http://dx.doi.org/10.1371/journal.pone.0203817 |
work_keys_str_mv | AT abellamonica enablingtomographywithlowcostcarmsystems AT demolinaclaudia enablingtomographywithlowcostcarmsystems AT ballesterosnerea enablingtomographywithlowcostcarmsystems AT garciasantosalba enablingtomographywithlowcostcarmsystems AT martinezalvaro enablingtomographywithlowcostcarmsystems AT garciaines enablingtomographywithlowcostcarmsystems AT descomanuel enablingtomographywithlowcostcarmsystems |