Cargando…
A Proposal for a Quality Control Protocol in Breast CT with Synchrotron Radiation
BACKGROUND: The SYRMA-3D collaboration is setting up the first clinical trial of phase-contrast breast CT with synchrotron radiation at the Elettra synchrotron facility in Trieste, Italy. In this communication, a quality control protocol for breast CT is proposed, and a first test of image quality m...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sciendo
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6137353/ https://www.ncbi.nlm.nih.gov/pubmed/30210044 http://dx.doi.org/10.2478/raon-2018-0015 |
_version_ | 1783355170158018560 |
---|---|
author | Contillo, Adriano Veronese, Anna Brombal, Luca Donato, Sandro Rigon, Luigi Taibi, Angelo Tromba, Giuliana Longo, Renata Arfelli, Fulvia |
author_facet | Contillo, Adriano Veronese, Anna Brombal, Luca Donato, Sandro Rigon, Luigi Taibi, Angelo Tromba, Giuliana Longo, Renata Arfelli, Fulvia |
author_sort | Contillo, Adriano |
collection | PubMed |
description | BACKGROUND: The SYRMA-3D collaboration is setting up the first clinical trial of phase-contrast breast CT with synchrotron radiation at the Elettra synchrotron facility in Trieste, Italy. In this communication, a quality control protocol for breast CT is proposed, and a first test of image quality measurements is performed by means of a custom-made radiographic phantom. MATERIALS AND METHODS: A set of projections is acquired and used to perform a CT reconstruction of two selected portions of the phantom. Such portions contain a uniform layer of water and a set of radiographic inserts, respectively. Together, they allow to perform several image quality measurements, namely CT number linearity, reconstruction accuracy, uniformity, noise, and low contrast resolution. All measurements are repeated at different beam energies in the range of interest, and at two different dose values. RESULTS: Measurements show a good linearity in the soft tissue range, paired to a high accuracy of the CT number reconstruction. Uniformity and noise measurements show that reconstruction inhomogeneities are bound to a few percent of the average pixel values. However, low contrast detectability is limited to the higher portion of the explored energy range. CONCLUSIONS: The results of the measurements are satisfactory in terms of their quality, feasibility and reproducibility. With minimal modifications, the phantom is promising to allow a set of image quality measurements to be used in the upcoming clinical trial. |
format | Online Article Text |
id | pubmed-6137353 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Sciendo |
record_format | MEDLINE/PubMed |
spelling | pubmed-61373532018-09-14 A Proposal for a Quality Control Protocol in Breast CT with Synchrotron Radiation Contillo, Adriano Veronese, Anna Brombal, Luca Donato, Sandro Rigon, Luigi Taibi, Angelo Tromba, Giuliana Longo, Renata Arfelli, Fulvia Radiol Oncol Research Article BACKGROUND: The SYRMA-3D collaboration is setting up the first clinical trial of phase-contrast breast CT with synchrotron radiation at the Elettra synchrotron facility in Trieste, Italy. In this communication, a quality control protocol for breast CT is proposed, and a first test of image quality measurements is performed by means of a custom-made radiographic phantom. MATERIALS AND METHODS: A set of projections is acquired and used to perform a CT reconstruction of two selected portions of the phantom. Such portions contain a uniform layer of water and a set of radiographic inserts, respectively. Together, they allow to perform several image quality measurements, namely CT number linearity, reconstruction accuracy, uniformity, noise, and low contrast resolution. All measurements are repeated at different beam energies in the range of interest, and at two different dose values. RESULTS: Measurements show a good linearity in the soft tissue range, paired to a high accuracy of the CT number reconstruction. Uniformity and noise measurements show that reconstruction inhomogeneities are bound to a few percent of the average pixel values. However, low contrast detectability is limited to the higher portion of the explored energy range. CONCLUSIONS: The results of the measurements are satisfactory in terms of their quality, feasibility and reproducibility. With minimal modifications, the phantom is promising to allow a set of image quality measurements to be used in the upcoming clinical trial. Sciendo 2018-03-24 /pmc/articles/PMC6137353/ /pubmed/30210044 http://dx.doi.org/10.2478/raon-2018-0015 Text en © 2018 Adriano Contillo, Anna Veronese, Luca Brombal, Sandro Donato, Luigi Rigon, Angelo Taibi, Giuliana Tromba, Renata Longo, Fulvia Arfelli, published by Sciendo http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. |
spellingShingle | Research Article Contillo, Adriano Veronese, Anna Brombal, Luca Donato, Sandro Rigon, Luigi Taibi, Angelo Tromba, Giuliana Longo, Renata Arfelli, Fulvia A Proposal for a Quality Control Protocol in Breast CT with Synchrotron Radiation |
title | A Proposal for a Quality Control Protocol in Breast CT with Synchrotron Radiation |
title_full | A Proposal for a Quality Control Protocol in Breast CT with Synchrotron Radiation |
title_fullStr | A Proposal for a Quality Control Protocol in Breast CT with Synchrotron Radiation |
title_full_unstemmed | A Proposal for a Quality Control Protocol in Breast CT with Synchrotron Radiation |
title_short | A Proposal for a Quality Control Protocol in Breast CT with Synchrotron Radiation |
title_sort | proposal for a quality control protocol in breast ct with synchrotron radiation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6137353/ https://www.ncbi.nlm.nih.gov/pubmed/30210044 http://dx.doi.org/10.2478/raon-2018-0015 |
work_keys_str_mv | AT contilloadriano aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT veroneseanna aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT bromballuca aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT donatosandro aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT rigonluigi aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT taibiangelo aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT trombagiuliana aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT longorenata aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT arfellifulvia aproposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT contilloadriano proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT veroneseanna proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT bromballuca proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT donatosandro proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT rigonluigi proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT taibiangelo proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT trombagiuliana proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT longorenata proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation AT arfellifulvia proposalforaqualitycontrolprotocolinbreastctwithsynchrotronradiation |