Evaluation of Two-dimensional Dose Distributions for Pre-treatment Patient-specific IMRT Dosimetry
BACKGROUND: The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionization chamber array inside a homogeneous phantom usin...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sciendo
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6137356/ https://www.ncbi.nlm.nih.gov/pubmed/30210046 http://dx.doi.org/10.2478/raon-2018-0019 |
_version_ | 1783355170857418752 |
---|---|
author | Radojcic, Đeni Smilovic Rajlic, David Casar, Bozidar Kolacio, Manda Svabic Obajdin, Nevena Faj, Dario Jurkovic, Slaven |
author_facet | Radojcic, Đeni Smilovic Rajlic, David Casar, Bozidar Kolacio, Manda Svabic Obajdin, Nevena Faj, Dario Jurkovic, Slaven |
author_sort | Radojcic, Đeni Smilovic |
collection | PubMed |
description | BACKGROUND: The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionization chamber array inside a homogeneous phantom using gamma method. Nevertheless, this method does not replicate the realistic conditions present when a patient is undergoing therapy. Therefore, to more accurately evaluate the treatment planning system (TPS) capabilities, gamma passing rates were examined for beams of different complexity passing through inhomogeneous phantoms. MATERIALS AND METHODS: The research was performed using Siemens Oncor Expression linear accelerator, Siemens Somatom Open CT simulator and Elekta Monaco TPS. A 2D detector array was used to evaluate dose distribution accuracy in homogeneous, semi-anthropomorphic and anthropomorphic phantoms. Validation was based on gamma analysis with 3%/3mm and 2%/2mm criteria, respectively. RESULTS: Passing rates of the complex dose distributions degrade depending on the thickness of non-water equivalent material. They also depend on dose reporting mode used. It is observed that the passing rate decreases with plan complexity. Comparison of the data for all set-ups of semi-anthropomorphic and anthropomorphic phantoms shows that passing rates are higher in the anthropomorphic phantom. CONCLUSIONS: Presented results raise a question of possible limits of dose distribution verification in assessment of plan delivery quality. Consequently, good results obtained using standard patient specific dosimetry methodology do not guarantee the accuracy of delivered dose distribution in real clinical cases. |
format | Online Article Text |
id | pubmed-6137356 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Sciendo |
record_format | MEDLINE/PubMed |
spelling | pubmed-61373562018-09-14 Evaluation of Two-dimensional Dose Distributions for Pre-treatment Patient-specific IMRT Dosimetry Radojcic, Đeni Smilovic Rajlic, David Casar, Bozidar Kolacio, Manda Svabic Obajdin, Nevena Faj, Dario Jurkovic, Slaven Radiol Oncol Research Article BACKGROUND: The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionization chamber array inside a homogeneous phantom using gamma method. Nevertheless, this method does not replicate the realistic conditions present when a patient is undergoing therapy. Therefore, to more accurately evaluate the treatment planning system (TPS) capabilities, gamma passing rates were examined for beams of different complexity passing through inhomogeneous phantoms. MATERIALS AND METHODS: The research was performed using Siemens Oncor Expression linear accelerator, Siemens Somatom Open CT simulator and Elekta Monaco TPS. A 2D detector array was used to evaluate dose distribution accuracy in homogeneous, semi-anthropomorphic and anthropomorphic phantoms. Validation was based on gamma analysis with 3%/3mm and 2%/2mm criteria, respectively. RESULTS: Passing rates of the complex dose distributions degrade depending on the thickness of non-water equivalent material. They also depend on dose reporting mode used. It is observed that the passing rate decreases with plan complexity. Comparison of the data for all set-ups of semi-anthropomorphic and anthropomorphic phantoms shows that passing rates are higher in the anthropomorphic phantom. CONCLUSIONS: Presented results raise a question of possible limits of dose distribution verification in assessment of plan delivery quality. Consequently, good results obtained using standard patient specific dosimetry methodology do not guarantee the accuracy of delivered dose distribution in real clinical cases. Sciendo 2018-04-30 /pmc/articles/PMC6137356/ /pubmed/30210046 http://dx.doi.org/10.2478/raon-2018-0019 Text en © 2018 Đeni Smilovic Radojcic, David Rajlic, Bozidar Casar, Manda Svabic Kolacio, Nevena Obajdin, Dario Faj, Slaven Jurkovic, published by Sciendo http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. |
spellingShingle | Research Article Radojcic, Đeni Smilovic Rajlic, David Casar, Bozidar Kolacio, Manda Svabic Obajdin, Nevena Faj, Dario Jurkovic, Slaven Evaluation of Two-dimensional Dose Distributions for Pre-treatment Patient-specific IMRT Dosimetry |
title | Evaluation of Two-dimensional Dose Distributions for Pre-treatment Patient-specific IMRT Dosimetry |
title_full | Evaluation of Two-dimensional Dose Distributions for Pre-treatment Patient-specific IMRT Dosimetry |
title_fullStr | Evaluation of Two-dimensional Dose Distributions for Pre-treatment Patient-specific IMRT Dosimetry |
title_full_unstemmed | Evaluation of Two-dimensional Dose Distributions for Pre-treatment Patient-specific IMRT Dosimetry |
title_short | Evaluation of Two-dimensional Dose Distributions for Pre-treatment Patient-specific IMRT Dosimetry |
title_sort | evaluation of two-dimensional dose distributions for pre-treatment patient-specific imrt dosimetry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6137356/ https://www.ncbi.nlm.nih.gov/pubmed/30210046 http://dx.doi.org/10.2478/raon-2018-0019 |
work_keys_str_mv | AT radojcicđenismilovic evaluationoftwodimensionaldosedistributionsforpretreatmentpatientspecificimrtdosimetry AT rajlicdavid evaluationoftwodimensionaldosedistributionsforpretreatmentpatientspecificimrtdosimetry AT casarbozidar evaluationoftwodimensionaldosedistributionsforpretreatmentpatientspecificimrtdosimetry AT kolaciomandasvabic evaluationoftwodimensionaldosedistributionsforpretreatmentpatientspecificimrtdosimetry AT obajdinnevena evaluationoftwodimensionaldosedistributionsforpretreatmentpatientspecificimrtdosimetry AT fajdario evaluationoftwodimensionaldosedistributionsforpretreatmentpatientspecificimrtdosimetry AT jurkovicslaven evaluationoftwodimensionaldosedistributionsforpretreatmentpatientspecificimrtdosimetry |