Cargando…
A single-step sizing and radiofrequency ablation catheter for circumferential ablation of Barrett's esophagus: Results of a pilot study
BACKGROUND: The 360 Express balloon catheter (360 Express) has the ability to self-adjust to the esophageal lumen, ensuring optimal tissue contact. OBJECTIVE: The objective of this article is to evaluate the efficacy and safety of the 360 Express for radiofrequency ablation (RFA) treatment of Barret...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6137598/ https://www.ncbi.nlm.nih.gov/pubmed/30228886 http://dx.doi.org/10.1177/2050640618768919 |
_version_ | 1783355202713157632 |
---|---|
author | Belghazi, K Pouw, RE Sondermeijer, CMT Meijer, SL Schoon, EJ Koch, AD Weusten, BLAM Bergman, JJGHM |
author_facet | Belghazi, K Pouw, RE Sondermeijer, CMT Meijer, SL Schoon, EJ Koch, AD Weusten, BLAM Bergman, JJGHM |
author_sort | Belghazi, K |
collection | PubMed |
description | BACKGROUND: The 360 Express balloon catheter (360 Express) has the ability to self-adjust to the esophageal lumen, ensuring optimal tissue contact. OBJECTIVE: The objective of this article is to evaluate the efficacy and safety of the 360 Express for radiofrequency ablation (RFA) treatment of Barrett's esophagus (BE). METHODS: BE patients with low-grade dysplasia (LGD), high-grade dysplasia (HGD) or early cancer (EC) were included. Visible lesions were removed by endoscopic resection (ER) prior to RFA. RFA was performed with the 360 Express using the standard ablation regimen (12J/cm(2)–clean–12J/cm(2)). Primary outcome: BE regression percentage at three months. Secondary outcomes: procedure time, adverse events, complete eradication of dysplasia (CE-D) and intestinal metaplasia (CE-IM). RESULTS: Thirty patients (median BE C4M6) were included. Eight patients underwent ER prior to RFA. Median BE regression: 90%. Median procedure time: 31 minutes. Adverse events (13%): laceration (n = 1); atrial fibrillation (n = 1); vomiting and dysphagia (n = 1); dysregulated diabetes (n = 1). After subsequent treatment CE-D and CE-IM was achieved in 97% and 87%, respectively. In 10% a stenosis developed during additional treatment requiring a median of one dilation. CONCLUSION: This study shows that circumferential RFA using the 360 Express may shorten procedure time, while maintaining efficacy compared to standard circumferential RFA. |
format | Online Article Text |
id | pubmed-6137598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-61375982018-09-18 A single-step sizing and radiofrequency ablation catheter for circumferential ablation of Barrett's esophagus: Results of a pilot study Belghazi, K Pouw, RE Sondermeijer, CMT Meijer, SL Schoon, EJ Koch, AD Weusten, BLAM Bergman, JJGHM United European Gastroenterol J Original Articles BACKGROUND: The 360 Express balloon catheter (360 Express) has the ability to self-adjust to the esophageal lumen, ensuring optimal tissue contact. OBJECTIVE: The objective of this article is to evaluate the efficacy and safety of the 360 Express for radiofrequency ablation (RFA) treatment of Barrett's esophagus (BE). METHODS: BE patients with low-grade dysplasia (LGD), high-grade dysplasia (HGD) or early cancer (EC) were included. Visible lesions were removed by endoscopic resection (ER) prior to RFA. RFA was performed with the 360 Express using the standard ablation regimen (12J/cm(2)–clean–12J/cm(2)). Primary outcome: BE regression percentage at three months. Secondary outcomes: procedure time, adverse events, complete eradication of dysplasia (CE-D) and intestinal metaplasia (CE-IM). RESULTS: Thirty patients (median BE C4M6) were included. Eight patients underwent ER prior to RFA. Median BE regression: 90%. Median procedure time: 31 minutes. Adverse events (13%): laceration (n = 1); atrial fibrillation (n = 1); vomiting and dysphagia (n = 1); dysregulated diabetes (n = 1). After subsequent treatment CE-D and CE-IM was achieved in 97% and 87%, respectively. In 10% a stenosis developed during additional treatment requiring a median of one dilation. CONCLUSION: This study shows that circumferential RFA using the 360 Express may shorten procedure time, while maintaining efficacy compared to standard circumferential RFA. SAGE Publications 2018-04-11 2018-08 /pmc/articles/PMC6137598/ /pubmed/30228886 http://dx.doi.org/10.1177/2050640618768919 Text en © Author(s) 2018 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Articles Belghazi, K Pouw, RE Sondermeijer, CMT Meijer, SL Schoon, EJ Koch, AD Weusten, BLAM Bergman, JJGHM A single-step sizing and radiofrequency ablation catheter for circumferential ablation of Barrett's esophagus: Results of a pilot study |
title | A single-step sizing and radiofrequency ablation catheter for circumferential ablation of Barrett's esophagus: Results of a pilot study |
title_full | A single-step sizing and radiofrequency ablation catheter for circumferential ablation of Barrett's esophagus: Results of a pilot study |
title_fullStr | A single-step sizing and radiofrequency ablation catheter for circumferential ablation of Barrett's esophagus: Results of a pilot study |
title_full_unstemmed | A single-step sizing and radiofrequency ablation catheter for circumferential ablation of Barrett's esophagus: Results of a pilot study |
title_short | A single-step sizing and radiofrequency ablation catheter for circumferential ablation of Barrett's esophagus: Results of a pilot study |
title_sort | single-step sizing and radiofrequency ablation catheter for circumferential ablation of barrett's esophagus: results of a pilot study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6137598/ https://www.ncbi.nlm.nih.gov/pubmed/30228886 http://dx.doi.org/10.1177/2050640618768919 |
work_keys_str_mv | AT belghazik asinglestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT pouwre asinglestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT sondermeijercmt asinglestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT meijersl asinglestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT schoonej asinglestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT kochad asinglestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT weustenblam asinglestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT bergmanjjghm asinglestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT belghazik singlestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT pouwre singlestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT sondermeijercmt singlestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT meijersl singlestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT schoonej singlestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT kochad singlestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT weustenblam singlestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy AT bergmanjjghm singlestepsizingandradiofrequencyablationcatheterforcircumferentialablationofbarrettsesophagusresultsofapilotstudy |