Cargando…
Open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit
The degeneration of bioprosthetic aortic Conduit with hemodynamic dysfunction mostly requires a re-do surgery, which is associated with an increased perioperative risk. Considering this, an open implantation of a transcatheter aortic bioprothesis (TAVI) after resection of the degenerated valve leafl...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6138824/ https://www.ncbi.nlm.nih.gov/pubmed/30250658 http://dx.doi.org/10.1093/jscr/rjy233 |
_version_ | 1783355408510877696 |
---|---|
author | Elghannam, Mahmoud Haldenwang, Peter-Lukas Aljabery, Yazan Moustafine, Vadim Strauch, Justus |
author_facet | Elghannam, Mahmoud Haldenwang, Peter-Lukas Aljabery, Yazan Moustafine, Vadim Strauch, Justus |
author_sort | Elghannam, Mahmoud |
collection | PubMed |
description | The degeneration of bioprosthetic aortic Conduit with hemodynamic dysfunction mostly requires a re-do surgery, which is associated with an increased perioperative risk. Considering this, an open implantation of a transcatheter aortic bioprothesis (TAVI) after resection of the degenerated valve leaflets could be of great benefit, reducing cross-clamp and cardiopulmonary bypass duration, especially in combined surgery in high-risk patients. This is a case of a high-risk female (78 years, EuroScore 59%) treated with an open TAVI as an alternative to conventional valve or aortic conduit replacement for degenerative aortic valve due to endocarditis lente, 2 years following a bio-Bentall procedure. |
format | Online Article Text |
id | pubmed-6138824 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-61388242018-09-24 Open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit Elghannam, Mahmoud Haldenwang, Peter-Lukas Aljabery, Yazan Moustafine, Vadim Strauch, Justus J Surg Case Rep Case Report The degeneration of bioprosthetic aortic Conduit with hemodynamic dysfunction mostly requires a re-do surgery, which is associated with an increased perioperative risk. Considering this, an open implantation of a transcatheter aortic bioprothesis (TAVI) after resection of the degenerated valve leaflets could be of great benefit, reducing cross-clamp and cardiopulmonary bypass duration, especially in combined surgery in high-risk patients. This is a case of a high-risk female (78 years, EuroScore 59%) treated with an open TAVI as an alternative to conventional valve or aortic conduit replacement for degenerative aortic valve due to endocarditis lente, 2 years following a bio-Bentall procedure. Oxford University Press 2018-09-15 /pmc/articles/PMC6138824/ /pubmed/30250658 http://dx.doi.org/10.1093/jscr/rjy233 Text en Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author(s) 2018. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report Elghannam, Mahmoud Haldenwang, Peter-Lukas Aljabery, Yazan Moustafine, Vadim Strauch, Justus Open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit |
title | Open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit |
title_full | Open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit |
title_fullStr | Open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit |
title_full_unstemmed | Open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit |
title_short | Open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit |
title_sort | open transcatheter aortic valve implantation on a degenerated bioprosthetic valve conduit |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6138824/ https://www.ncbi.nlm.nih.gov/pubmed/30250658 http://dx.doi.org/10.1093/jscr/rjy233 |
work_keys_str_mv | AT elghannammahmoud opentranscatheteraorticvalveimplantationonadegeneratedbioprostheticvalveconduit AT haldenwangpeterlukas opentranscatheteraorticvalveimplantationonadegeneratedbioprostheticvalveconduit AT aljaberyyazan opentranscatheteraorticvalveimplantationonadegeneratedbioprostheticvalveconduit AT moustafinevadim opentranscatheteraorticvalveimplantationonadegeneratedbioprostheticvalveconduit AT strauchjustus opentranscatheteraorticvalveimplantationonadegeneratedbioprostheticvalveconduit |