Cargando…

Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules

PURPOSE: The aim of the study was to compare three different elastography methods, namely Strain Elastography (SE), Point Shear-Wave Elastography (pSWE) using Acoustic Radiation Force Impulse (ARFI)-Imaging and 2D-Shear Wave Elastography (2D-SWE), in the same study population for the differentiation...

Descripción completa

Detalles Bibliográficos
Autores principales: Kyriakidou, Georgia, Friedrich-Rust, Mireen, Bon, Dimitra, Sircar, Ishani, Schrecker, Christopher, Bogdanou, Dimitra, Herrmann, Eva, Bojunga, Joerg
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141102/
https://www.ncbi.nlm.nih.gov/pubmed/30222755
http://dx.doi.org/10.1371/journal.pone.0204095
_version_ 1783355650105933824
author Kyriakidou, Georgia
Friedrich-Rust, Mireen
Bon, Dimitra
Sircar, Ishani
Schrecker, Christopher
Bogdanou, Dimitra
Herrmann, Eva
Bojunga, Joerg
author_facet Kyriakidou, Georgia
Friedrich-Rust, Mireen
Bon, Dimitra
Sircar, Ishani
Schrecker, Christopher
Bogdanou, Dimitra
Herrmann, Eva
Bojunga, Joerg
author_sort Kyriakidou, Georgia
collection PubMed
description PURPOSE: The aim of the study was to compare three different elastography methods, namely Strain Elastography (SE), Point Shear-Wave Elastography (pSWE) using Acoustic Radiation Force Impulse (ARFI)-Imaging and 2D-Shear Wave Elastography (2D-SWE), in the same study population for the differentiation of thyroid nodules. MATERIALS AND METHODS: All patients received a conventional ultrasound scan, SE and 2D-SWE, and all patients except for two received ARFI-Imaging. Cytology/histology of thyroid nodules was used as a reference method. SE measures the relative stiffness within the region of interest (ROI) using the surrounding tissue as reference tissue. ARFI mechanically excites the tissue at the ROI using acoustic pulses to generate localized tissue displacements. 2D-SWE measures tissue elasticity using the velocity of many shear waves as they propagate through the tissue. RESULTS: 84 nodules (73 benign and 11 malignant) in 62 patients were analyzed. Sensitivity, specificity and NPV of SE were 73%, 70% and 94%, respectively. Sensitivity, specificity and NPV of ARFI and 2D-SWE were 90%, 79%, 98% and 73%, 67%, 94% respectively, using a cut-off value of 1.98m/s for ARFI and 2.65m/s (21.07kPa) for 2D-SWE. The AUROC (Area under the Receiver Operating Characteristic) of SE, ARFI and 2D-SWE for the diagnosis of malignant thyroid nodules were 52%, 86% and 71%, respectively. A significant difference in AUROC was found between SE and ARFI (p = 0.008), while no significant difference was found between ARFI and SWE (86% vs. 71%, p = 0.31), or SWE and SE (71% vs. 52%, p = 0.26). CONCLUSION: pSWE using ARFI and 2D-SWE showed comparable results for the differentiation of thyroid nodules. ARFI was superior to elastography using SE.
format Online
Article
Text
id pubmed-6141102
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61411022018-09-21 Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules Kyriakidou, Georgia Friedrich-Rust, Mireen Bon, Dimitra Sircar, Ishani Schrecker, Christopher Bogdanou, Dimitra Herrmann, Eva Bojunga, Joerg PLoS One Research Article PURPOSE: The aim of the study was to compare three different elastography methods, namely Strain Elastography (SE), Point Shear-Wave Elastography (pSWE) using Acoustic Radiation Force Impulse (ARFI)-Imaging and 2D-Shear Wave Elastography (2D-SWE), in the same study population for the differentiation of thyroid nodules. MATERIALS AND METHODS: All patients received a conventional ultrasound scan, SE and 2D-SWE, and all patients except for two received ARFI-Imaging. Cytology/histology of thyroid nodules was used as a reference method. SE measures the relative stiffness within the region of interest (ROI) using the surrounding tissue as reference tissue. ARFI mechanically excites the tissue at the ROI using acoustic pulses to generate localized tissue displacements. 2D-SWE measures tissue elasticity using the velocity of many shear waves as they propagate through the tissue. RESULTS: 84 nodules (73 benign and 11 malignant) in 62 patients were analyzed. Sensitivity, specificity and NPV of SE were 73%, 70% and 94%, respectively. Sensitivity, specificity and NPV of ARFI and 2D-SWE were 90%, 79%, 98% and 73%, 67%, 94% respectively, using a cut-off value of 1.98m/s for ARFI and 2.65m/s (21.07kPa) for 2D-SWE. The AUROC (Area under the Receiver Operating Characteristic) of SE, ARFI and 2D-SWE for the diagnosis of malignant thyroid nodules were 52%, 86% and 71%, respectively. A significant difference in AUROC was found between SE and ARFI (p = 0.008), while no significant difference was found between ARFI and SWE (86% vs. 71%, p = 0.31), or SWE and SE (71% vs. 52%, p = 0.26). CONCLUSION: pSWE using ARFI and 2D-SWE showed comparable results for the differentiation of thyroid nodules. ARFI was superior to elastography using SE. Public Library of Science 2018-09-17 /pmc/articles/PMC6141102/ /pubmed/30222755 http://dx.doi.org/10.1371/journal.pone.0204095 Text en © 2018 Kyriakidou et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kyriakidou, Georgia
Friedrich-Rust, Mireen
Bon, Dimitra
Sircar, Ishani
Schrecker, Christopher
Bogdanou, Dimitra
Herrmann, Eva
Bojunga, Joerg
Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules
title Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules
title_full Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules
title_fullStr Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules
title_full_unstemmed Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules
title_short Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules
title_sort comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2d-shear wave elastography for the differentiation of thyroid nodules
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141102/
https://www.ncbi.nlm.nih.gov/pubmed/30222755
http://dx.doi.org/10.1371/journal.pone.0204095
work_keys_str_mv AT kyriakidougeorgia comparisonofstrainelastographypointshearwaveelastographyusingacousticradiationforceimpulseimagingand2dshearwaveelastographyforthedifferentiationofthyroidnodules
AT friedrichrustmireen comparisonofstrainelastographypointshearwaveelastographyusingacousticradiationforceimpulseimagingand2dshearwaveelastographyforthedifferentiationofthyroidnodules
AT bondimitra comparisonofstrainelastographypointshearwaveelastographyusingacousticradiationforceimpulseimagingand2dshearwaveelastographyforthedifferentiationofthyroidnodules
AT sircarishani comparisonofstrainelastographypointshearwaveelastographyusingacousticradiationforceimpulseimagingand2dshearwaveelastographyforthedifferentiationofthyroidnodules
AT schreckerchristopher comparisonofstrainelastographypointshearwaveelastographyusingacousticradiationforceimpulseimagingand2dshearwaveelastographyforthedifferentiationofthyroidnodules
AT bogdanoudimitra comparisonofstrainelastographypointshearwaveelastographyusingacousticradiationforceimpulseimagingand2dshearwaveelastographyforthedifferentiationofthyroidnodules
AT herrmanneva comparisonofstrainelastographypointshearwaveelastographyusingacousticradiationforceimpulseimagingand2dshearwaveelastographyforthedifferentiationofthyroidnodules
AT bojungajoerg comparisonofstrainelastographypointshearwaveelastographyusingacousticradiationforceimpulseimagingand2dshearwaveelastographyforthedifferentiationofthyroidnodules